FFQ25~60B7V1B
Split system air conditioners
4PW18600-1
Operation manual
7
ANNEX II
ONLY FOR AUSTRALIAN MODELS
Cooling, heating, automatic, fan, and program dry operation
Operate in the following order.
1
Operation mode selector
Press OPERATION MODE SELECTOR button several times and
select the OPERATION MODE of your choice as follows.
■
COOLING OPERATION ................................................"
"
■
HEATING OPERATION.................................................."
"
■
AUTOMATIC OPERATION............................................ "
"
-
In this operation mode, COOL/HEAT changeover is
automatically conducted.
■
FAN OPERATION ......................................................... "
"
■
DRY OPERATION......................................................... "
"
-
The function of this program is to decrease the humidity in
your room with the minimum temperature decrease.
-
Micro computer automatically determines
TEMPERATURE and FAN SPEED.
-
This system does not go into operation if the room
temperature is below 16°C.
-
For cooling only type, "COOLING", "FAN" and "DRY"
operation are able to select.
2
ON/OFF
Press ON/OFF BUTTON.
OPERATION lamp lights up or goes off and the system starts or
stops OPERATION.
[Explanation of heating operation]
Defrost operation
■
As the frost on the coil of an outdoor unit increase, heating
effect decreases and the system goes into DEFROST
OPERATION.
■
The indoor unit fan stops and the remote controller display
shows "
".
■
After 6 to 8 minutes (maximum 10 minutes) of DEFROST
OPERATION, the system returns to HEATING OPERATION.
Regarding outside air temperature and heating capacity
■
The heating capacity of the air conditioner declines as the
outside air temperature falls. In such a case, use the air
conditioner in combination with other heating systems.
■
A warm air circulating system is employed, and therefore it
takes some time until the entire room is warmed up after the
start of operation.
■
An indoor fan runs to discharge a gentle wind automatically
until the temperature inside the air conditioner reaches a
certain level. At this time, the remote controller displays
"
". Leave it as it stands and wait for a while.
■
When the warm air stays under the ceiling and your feet are
cold, we recommend that you use a circulator (a fan to
circulate the air inside the room). For details, consult your
dealer.
Adjustment
For programming TEMPERATURE, FAN SPEED and AIR FLOW
DIRECTION, follow the procedure shown below.
Temperature setting
Press TEMPERATURE SETTING button and program the setting
temperature.
The setting is impossible for fan operation.
Fan speed control
Press FAN SPEED CONTROL button.
High or Low fan speed can be selected.
The micro computer may sometimes control the fan speed in order to
protect the unit.
Air flow direction adjust
Press the AIR FLOW DIRECTION ADJUST button to adjust the air
flow angle.
The movable limit of the flap is changeable. Contact your dealer for
details.
Press the air flow direction adjust button to select the air
direction as follows.
Movement of the air flow flap
For the following conditions, micro computer controls the air flow
direction so it may be different from the display.
Operation mode includes automatic operation.
Each time this button is pressed, setting temperature
rises 1°C.
Each time this button is pressed, setting temperature
lowers 1°C.
Up and down adjustment
The AIR FLOW FLAP display swings as shown the left and the air
flow direction continuously varies. (Automatic swing setting)
Press AIR FLOW DIRECTION ADJUST button to select the air
direction of your choice.
The AIR FLOW FLAP display stops swinging and the air flow
direction is fixed (Fixed air flow direction setting).
Operation mode
Cooling
Heating
Operation
condition
When room temperature is
lower than the set
temperature
When room temperature
is higher than the set
temperature
At defrost operation
When operating continuously at downward air flow
direction