FFQ25~60B7V1B
Split system air conditioners
4PW18600-1

Operation manual

7

ANNEX II 

ONLY FOR AUSTRALIAN MODELS

Cooling, heating, automatic, fan, and program dry operation

Operate in the following order.

1

Operation mode selector 

Press OPERATION MODE SELECTOR button several times and
select the OPERATION MODE of your choice as follows.

COOLING OPERATION ................................................"

"

HEATING OPERATION.................................................."

"

AUTOMATIC OPERATION............................................ "

"

-

In this operation mode, COOL/HEAT changeover is 
automatically conducted.

FAN OPERATION ......................................................... "

"

DRY OPERATION......................................................... "

"

-

The function of this program is to decrease the humidity in 
your room with the minimum temperature decrease.

-

Micro computer automatically determines 
TEMPERATURE and FAN SPEED.

-

This system does not go into operation if the room 
temperature is below 16°C. 

-

For cooling only type, "COOLING", "FAN" and "DRY" 
operation are able to select.

2

ON/OFF 

Press ON/OFF BUTTON.

OPERATION lamp lights up or goes off and the system starts or
stops OPERATION.

[Explanation of heating operation]

Defrost operation

As the frost on the coil of an outdoor unit increase, heating
effect decreases and the system goes into DEFROST
OPERATION.

The indoor unit fan stops and the remote controller display
shows "

".

After 6 to 8 minutes (maximum 10 minutes) of DEFROST
OPERATION, the system returns to HEATING OPERATION.

Regarding outside air temperature and heating capacity

The heating capacity of the air conditioner declines as the
outside air temperature falls. In such a case, use the air
conditioner in combination with other heating systems.

A warm air circulating system is employed, and therefore it
takes some time until the entire room is warmed up after the
start of operation.

An indoor fan runs to discharge a gentle wind automatically
until the temperature inside the air conditioner reaches a
certain level. At this time, the remote controller displays
"

". Leave it as it stands and wait for a while.

When the warm air stays under the ceiling and your feet are
cold, we recommend that you use a circulator (a fan to
circulate the air inside the room). For details, consult your
dealer.

Adjustment

For programming TEMPERATURE, FAN SPEED and AIR FLOW
DIRECTION, follow the procedure shown below.

Temperature setting 

Press TEMPERATURE SETTING button and program the setting
temperature.

The setting is impossible for fan operation.

Fan speed control 

Press FAN SPEED CONTROL button.

High or Low fan speed can be selected.

The micro computer may sometimes control the fan speed in order to
protect the unit.

Air flow direction adjust 

Press the AIR FLOW DIRECTION ADJUST button to adjust the air
flow angle.

The movable limit of the flap is changeable. Contact your dealer for
details.

Press the air flow direction adjust button to select the air
direction as follows.

Movement of the air flow flap

For the following conditions, micro computer controls the air flow
direction so it may be different from the display.

Operation mode includes automatic operation.

Each time this button is pressed, setting temperature 
rises 1°C.

Each time this button is pressed, setting temperature 
lowers 1°C.

Up and down adjustment

The AIR FLOW FLAP display swings as shown the left and the air 
flow direction continuously varies. (Automatic swing setting)

Press AIR FLOW DIRECTION ADJUST button to select the air 
direction of your choice.

The AIR FLOW FLAP display stops swinging and the air flow 
direction is fixed (Fixed air flow direction setting).

Operation mode

Cooling

Heating

Operation 

condition

When room temperature is 

lower than the set 

temperature

When room temperature 

is higher than the set 

temperature

At defrost operation

When operating continuously at downward air flow 

direction

Summary of Contents for FFQ25B7V1B

Page 1: ...OPERATION MANUAL FFQ25B7V1B FFQ35B7V1B FFQ50B7V1B FFQ60B7V1B Split system air conditioners...

Page 2: ...6 3 5 4 2 1 2 3 4 4 7 8 3 9 2 6 5 1 1 1 1 A B 1 2 3 4 5 6...

Page 3: ...NOTE These units can be controlled by a remote controller Refer to the manual of the remote controller for more information A Pair system B Multi system 1 Unit with remote controller 1 Indoor unit 2...

Page 4: ...mediately because one of its safety devices actuates to prevent the system from being overloaded The system will turn on again automatically after three minutes The system does not restart immediately...

Page 5: ...ite mist comes out of a unit When humidity is high during cooling operation In oily or dusty places If the inside of an indoor unit is extremely contaminated the temperature distribution inside a room...

Page 6: ...r blinds When there are too many inhabitants in the room Cooling effect decreases if heat gain of the room is too large If the heat source of the room is excessive when cooling Cooling effect decrease...

Page 7: ...t blocked Remove any obstacle Check if the earth is connected Clean the air filter and outside panels After cleaning the air filter make sure to attach it Turn on the main power supply switch The cont...

Page 8: ...air filter on page 4 12 DISPLAY DEFROST Refer to Defrost operation on page 7 13 NON FUNCTIONING DISPLAY If that particular function is not available pressing the button may display the words NOT AVAIL...

Page 9: ...mperature inside the air conditioner reaches a certain level At this time the remote controller displays Leave it as it stands and wait for a while When the warm air stays under the ceiling and your f...

Page 10: ...g the timer start 2 PROGRAMMING TIME Press the PROGRAMMING TIME button and set the time for stopping or starting the system 3 TIMER ON OFF Press the TIMER ON OFF BUTTON The timer setting procedure end...

Page 11: ...NOTES NOTES...

Page 12: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN18600 1...

Reviews: