background image

3 Operation

Operation manual

3

FDXM25~60F3V1B
Split system air conditioners
4P456959-1 – 2017.03

b

c

a

e

d

f

h

a

Indoor unit

b

Outdoor unit

c

User interface

d

Air inlet

e

Air outlet

f

Refrigerant piping and electric wiring

g

Drain pipe

h

Earth wire to ground outdoor unit to prevent electric
shocks.

CAUTION

Do not insert fingers, rods or other objects into the air inlet
or  outlet.  Do  not  remove  the  fan  guard.  When  the  fan  is
rotating at high speed, it will cause injury.

CAUTION

Never touch the internal parts of the controller.

Do  not  remove  the  front  panel.  Some  parts  inside  are
dangerous  to  touch  and  appliance  problems  may  happen.
For checking and adjusting the internal parts, contact your
dealer.

NOTICE

Do  not  wipe  the  controller  operation  panel  with  benzine,
thinner,  chemical  dust  cloth,  etc.  The  panel  may  get
discoloured  or  the  coating  peeled  off.  If  it  is  heavily  dirty,
soak  a  cloth  in  water-diluted  neutral  detergent,  squeeze  it
well  and  wipe  the  panel  clean.  Wipe  it  with  another  dry
cloth.

NOTICE

Never  press  the  button  of  the  user  interface  with  a  hard,
pointed object. The user interface may be damaged.

NOTICE

Never pull or twist the electric wire of the user interface. It
may cause the unit to malfunction.

3

Operation

3.1

Operation range

For combination with R410A outdoor unit, refer to the following table:

Outdoor units

Cooling

Heating

RR71~125

Outdoor
temperature

–15~46°C DB

Indoor
temperature

18~37°C DB

12~28°C WB

RQ71~125

Outdoor
temperature

–5~46°C DB

–9~21°C DB

–10~15°C WB

Indoor
temperature

18~37°C DB

12~28°C WB

10~27°C DB

RXS25~60

Outdoor
temperature

–10~46°C DB

–15~24°C DB

–16~18°C WB

Indoor
temperature

18~32°C DB

10~30°C DB

2MXS50

Outdoor
temperature

10~46°C DB

–15~24°C DB

–16~18°C WB

Indoor
temperature

18~32°C DB

10~30°C DB

3MXS40~68

4MXS68~80

5MXS90

Outdoor
temperature

–10~46°C DB

–15~24°C DB

–16~18°C WB

Indoor
temperature

18~32°C DB

10~30°C DB

RZQG71~140

Outdoor
temperature

–15~50°C DB

–19~21°C DB

–20~15.5°C WB

Indoor
temperature

18~37°C DB

12~28°C WB

10~27°C DB

RZQSG71~140

Outdoor
temperature

–15~46°C DB

–14~21°C DB

–15~15.5°C WB

Indoor
temperature

20~37°C DB

14~28°C WB

10~27°C DB

RZQ200~250

Outdoor
temperature

–5~46°C DB

–14~21°C DB

–15~15°C WB

Indoor
temperature

20~37°C DB

14~28°C WB

10~27°C DB

For combination with R32 outdoor unit, refer to the following table:

Outdoor units

Cooling

Heating

2MXM50

3MXM40~68

4MXM68~80

5MXM90

Outdoor
temperature

–10~46°C DB

–15~24°C DB

–16~18°C WB

Indoor
temperature

–18~32°C DB

10~30°C DB

RXM25~60

Outdoor
temperature

–10~46°C DB

–15~24°C DB

–16~18°C WB

Indoor
temperature

18~32°C DB

10~30°C DB

RZAG71~140

Outdoor
temperature

–20~52°C DB

–19.5~21°C DB

–20~15.5°C WB

Indoor
temperature

18~37°C DB

12~28°C WB

10~27°C DB

Summary of Contents for FDXM25F3V1B

Page 1: ...Operation manual Split system air conditioners English Operation manual Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B...

Page 2: ...Format Paper in the box of the indoor unit Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer The original documentation is written in...

Page 3: ...tion range For combination with R410A outdoor unit refer to the following table Outdoor units Cooling Heating RR71 125 Outdoor temperature 15 46 C DB Indoor temperature 18 37 C DB 12 28 C WB RQ71 125...

Page 4: ...he main power supply switch to the unit when the unit is not used for longer periods of time If the switch is on it consumes electricity Before restarting the unit turn on the main power supply switch...

Page 5: ...elow 2 hooks for 25 and 35 type or 3 hooks for 50 and 60 type rear suction bottom suction 2 1 2 1 2 Clean the air filter Use a vacuum cleaner or wash with water If the air filter is very dirty use a s...

Page 6: ...still blinks contact your dealer Check if all indoor units connected to outdoor unit in the multi system are operating in the same mode An abnormal function happens during operation The air condition...

Page 7: ...again 6 1 5 Symptom The operation stopped suddenly Operation lamp is on The air conditioner may stop for system protection due to large voltage fluctuation It automatically resumes operation after ab...

Page 8: ...4P456959 1 2017 03 Copyright 2017 Daikin...

Reviews: