Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  off  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause breakage, electric shock or fire. Contact your dealer.

The system must be repaired by a qualified service person:

If  the  system  does  not  properly  operate  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  according  to  the  following
procedures.

Malfunction

Measure

If the system does not
operate at all.

▪ Check  if  there  is  no  power  failure.  Wait

until  power  is  restored.  If  power  failure
occurs  during  operation,  the  system
automatically  restarts  immediately  after
power is restored.

▪ Check if no fuse has blown or breaker is

activated.  Change  the  fuse  or  reset  the
breaker if necessary.

▪ Are batteries set in the remote controller?

▪ Is the timer setting correct?

The system operates,
but cooling or heating
is insufficient.

▪ Check  if  air  inlet  or  outlet  of  outdoor  or

indoor  unit  is  not  blocked  by  obstacles.
Remove  any  obstacles  and  make  sure
the air can flow freely.

▪ Check  if  the  air  filter  is  clogged.  Contact

your dealer to clean the air filter.

▪ Check  the  temperature  setting.  Refer  to

the manual of the user interface.

▪ Check  if  the  air  flow  angle  is  proper.

Refer to the manual of the user interface.

▪ Check the fan speed setting is set to low

speed.  Refer  to  the  manual  of  the  user
interface.

▪ Check for open doors or windows. Close

doors and windows to prevent wind from
coming in.

▪ Check  if  direct  sunlight  enters  the  room.

Use curtains or blinds.

▪ If  the  heat  source  of  the  room  is

excessive  (when  cooling).  Cooling  effect
decreases if heat gain of the room is too
large.

▪ Check if there are too many occupants in

the room during cooling operation. Check
if  the  heat  source  of  the  room  is
excessive.

Malfunction

Measure

Operation stops
suddenly. (Operation
lamp blinks.)

▪ Check  if  the  air  filter  is  clogged.  Contact

your dealer to clean the air filter (refer to
"Maintenance" in the indoor unit manual).

▪ Check  if  air  inlet  or  outlet  of  outdoor  or

indoor  unit  is  not  blocked  by  obstacles.
Remove  any  obstacles,  turn  the  breaker
OFF and back ON. If the lamp still blinks,
contact your dealer.

▪ Check  if  all  indoor  units  connected  to

outdoor  unit  in  the  multi-system  are
operating in the same mode.

An abnormal function
happens during
operation.

▪ The  air  conditioner  may  malfunction

because of lightning or radio waves. Turn
the breaker OFF and back ON.

If  after  checking  all  above  items,  it  is  impossible  to  fix  the  problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).

6.1

Symptoms that are NOT system
malfunctions

The following symptoms are NOT system malfunctions:

6.1.1

Symptom: The system does not operate

▪ The  air  conditioner  does  not  start  immediately  after  the  ON/OFF

button  on  the  user  interface  is  pressed.  If  the  operation  lamp
lights, the air conditioner is in normal condition. It does not restart
immediately because one of its safety devices actuates to prevent
the air conditioner from being overloaded. The air conditioner will
turn on again automatically after 3 minutes.

▪ The  air  conditioner  does  not  start  immediately  after  the  power

supply  is  turned  on.  Wait  1  minute  until  the  microcomputer  is
prepared for operation.

▪ The  air  conditioner  does  not  restart  immediately  when  the

temperature  setting  button  is  returned  to  its  former  position  after
pushing. It does not restart immediately because one of its safety
devices  actuates  to  prevent  the  air  conditioner  from  being
overloaded.  The  air  conditioner  will  turn  on  again  automatically
after 3 minutes.

▪ The  outdoor  unit  has  stopped.  This  is  because  the  room

temperature  has  reached  the  set  temperature.  The  unit  switches

to fan operation. "

" (external control icon) is displayed on

the  user  interface  and  the  actual  operation  is  different  from  the
user  interface  setting.  For  multi-split  models,  the  microcomputer
executes  the  following  control  depending  on  the  operation  mode
of other indoor units.

▪ The fan speed is different from the setting. Pressing the fan speed

control  button  does  not  change  the  fan  speed.  When  the  room
temperature  reaches  the  set  temperature  in  heating  mode  or  the
unit’s  maximum  capacity  is  reached,  the  outdoor  unit  will  stop
operation  and  the  indoor  unit  will  operate  in  fan  only  mode  (low
fan  speed).  In  case  of  multi-split,  the  indoor  unit  alternately
operates  in  fan  stop  mode  and  fan  only  mode  (LL=  low  fan
speed).  This  is  to  prevent  the  cool  air  from  being  blown  directly
onto anyone present in the room.

6.1.2

Symptom: White mist comes out of a unit
(Indoor unit)

▪ When humidity is high during cooling operation (in oily and dusty

places). If the interior of an indoor unit is extremely contaminated,
the  temperature  distribution  inside  a  room  becomes  uneven.  It  is

Summary of Contents for FDXM25F3V1B

Page 1: ...Operation manual Split system air conditioners English Operation manual Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B...

Page 2: ...Format Paper in the box of the indoor unit Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer The original documentation is written in...

Page 3: ...tion range For combination with R410A outdoor unit refer to the following table Outdoor units Cooling Heating RR71 125 Outdoor temperature 15 46 C DB Indoor temperature 18 37 C DB 12 28 C WB RQ71 125...

Page 4: ...he main power supply switch to the unit when the unit is not used for longer periods of time If the switch is on it consumes electricity Before restarting the unit turn on the main power supply switch...

Page 5: ...elow 2 hooks for 25 and 35 type or 3 hooks for 50 and 60 type rear suction bottom suction 2 1 2 1 2 Clean the air filter Use a vacuum cleaner or wash with water If the air filter is very dirty use a s...

Page 6: ...still blinks contact your dealer Check if all indoor units connected to outdoor unit in the multi system are operating in the same mode An abnormal function happens during operation The air condition...

Page 7: ...again 6 1 5 Symptom The operation stopped suddenly Operation lamp is on The air conditioner may stop for system protection due to large voltage fluctuation It automatically resumes operation after ab...

Page 8: ...4P456959 1 2017 03 Copyright 2017 Daikin...

Reviews: