background image

Table of Contents

Operation manual

2

FDXM25~60F3V1B

Split system air conditioners

4P456959-1 – 2017.03

Table of Contents

1 About this document

2

2 About the system

2

2.1

Components ..............................................................................

2

3 Operation

3

3.1

Operation range ........................................................................

3

4 Energy saving and optimum operation

4

5 Maintenance and service

4

5.1

Overview: Maintenance and service .........................................

4

5.2

To clean the drain pan...............................................................

5

5.3

Cleaning the air filter, suction grille, air outlet and outside
panels  .......................................................................................

5

5.3.1

To clean the air outlet and outside panels ..................

5

5.3.2

To clean the air filter ...................................................

5

5.4

Maintenance before a long stop period .....................................

5

5.5

Maintenance after a long stop period ........................................

5

6 Troubleshooting

6

6.1

Symptoms that are NOT system malfunctions ..........................

6

6.1.1

Symptom: The system does not operate ....................

6

6.1.2

Symptom: White mist comes out of a unit (Indoor
unit) .............................................................................

6

6.1.3

Symptom: Dust comes out of the unit .........................

7

6.1.4

Symptom: The units can give off odours.....................

7

6.1.5

Symptom: The operation stopped suddenly
(Operation lamp is on) ................................................

7

6.1.6

Symptom: The outdoor fan rotates while the air
conditioner is not in operation .....................................

7

6.1.7

Symptom: The heating operation stops suddenly and
a flowing sound is heard .............................................

7

7 Disposal

7

1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Keep the documentation for future reference.

Target audience

End users

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety  instructions  that  you  must  read  before  operating  your

system

▪ Format: Paper (in the box of the indoor unit)

Operation manual:

▪ Operation instructions

▪ Format: Paper (in the box of the indoor unit)

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

2

About the system

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

INFORMATION

The sound pressure level is less than 70 dBA.

WARNING: FLAMMABLE MATERIAL

The  R32  refrigerant  (if  applicable)  in  this  unit  is  mildly
flammable.

(a)

(a)

Refer to the outdoor unit specifications for the type of
refrigerant to be used.

WARNING

▪ Do not modify, disassemble, remove, reinstall or repair

the unit yourself as incorrect dismantling or installation
may  cause  an  electric  shock  or  fire.  Contact  your
dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe  and  non-toxic.  R410A  is  a  non-combustible
refrigerant,  and  R32  is  a  mildly  flammable  refrigerant,
but  they  will  generate  a  toxic  gas  when  they
accidentally  leak  into  a  room  where  combustible  air
from  fan  heaters,  gas  cookers,  etc.  is  present.  Always
have  qualified  service  personnel  confirm  that  the  point
of  leakage  has  been  repaired  or  corrected  before
resuming operation.

WARNING

Ask  your  dealer  to  install  and  reinstall  the  air  conditioner.
Incomplete  installation  may  result  in  a  water  leakage,
electric shock, and fire.

NOTICE

Improper  installation  or  attachment  of  equipment  or
accessories  could  result  in  electric  shock,  short-circuit,
leaks,  fire  or  other  damage  to  the  equipment.  Only  use
accessories,  optional  equipment  and  spare  parts  made  or
approved by Daikin.

2.1

Components

INFORMATION

The  following  illustration  is  an  example  and  might  NOT
match your system layout.

Summary of Contents for FDXM25F3V1B

Page 1: ...Operation manual Split system air conditioners English Operation manual Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B...

Page 2: ...Format Paper in the box of the indoor unit Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer The original documentation is written in...

Page 3: ...tion range For combination with R410A outdoor unit refer to the following table Outdoor units Cooling Heating RR71 125 Outdoor temperature 15 46 C DB Indoor temperature 18 37 C DB 12 28 C WB RQ71 125...

Page 4: ...he main power supply switch to the unit when the unit is not used for longer periods of time If the switch is on it consumes electricity Before restarting the unit turn on the main power supply switch...

Page 5: ...elow 2 hooks for 25 and 35 type or 3 hooks for 50 and 60 type rear suction bottom suction 2 1 2 1 2 Clean the air filter Use a vacuum cleaner or wash with water If the air filter is very dirty use a s...

Page 6: ...still blinks contact your dealer Check if all indoor units connected to outdoor unit in the multi system are operating in the same mode An abnormal function happens during operation The air condition...

Page 7: ...again 6 1 5 Symptom The operation stopped suddenly Operation lamp is on The air conditioner may stop for system protection due to large voltage fluctuation It automatically resumes operation after ab...

Page 8: ...4P456959 1 2017 03 Copyright 2017 Daikin...

Reviews: