Installation manual

5

FDY(P)125~2 FDQ125B7V3B

Split System air conditioners

4PW10621-1C

I

NTERNAL

 

WIRING

 - 

PARTS

 

TABLE

Refer to the wiring diagram on the unit.

The abbreviations used are listed below.

A1P ........................Printed circuit board 

A2P ......................... Printed circuit board (Transformer 220-240 V/16 V)

(only for FDY125, 200, 250)

A3P ........................Printed circuit board

C1R ........................Capacitor (Fan)

F1T.........................Thermal fuse (M1F embedded)

HAP, HBP ...............Light emitting diode (Service monitor - GREEN)

K1F.........................Magnetic contactor (M1F)

M1F ........................Motor (Fan)

R1T ........................Thermistor (air)

R2T ........................Thermistor (Coil)

RC ..........................Signal receiver circuit

RyF1.......................Magnetic relay (fan)

SS1 ........................Selector switch (Emergency)

T1R ........................Transformer

TC ..........................Signal transmission circuit

X1M........................Terminal strip

Adaptor for wiring

RyC, RyF................Magnetic relay

Connector for optional parts

X25A...................... Connector (Group control adaptor)

X30A...................... Connector (interface adaptor for Sky Air series)

(only for FDY(P)125~250)

X33A...................... Connector (Adaptor for wiring)

X40A...................... Connector (remote on/off, forced off)

X60A,X61A ............ Connector (interface adaptor for Sky Air series)

(only for FDQ)

Wired remote controller

BS2........................ Timer mode start/stop button

BS7........................ Timer on/off button

BS3-BS8................ Programming timer button

BS1........................ ON/OFF button

BS4........................ Temperature setting button up

BS6........................ Operation mode selector button

BS9........................ Temperature setting button down

BS12...................... INSPECTION/TEST operation button

BS14...................... Filter sign reset button

LCD ....................... Liquid Crystal Display

H1P ....................... Light emitting diode (Service monitor-Red)

SS1........................ Selector switch (MAIN/SUB)

NOTE

When using the central remote controller, see manual
for connection to the unit.

Ground the shield of the remote controller cord to the
indoor unit.

Be sure that power supply is switched off before open-
ing switch box.

: FIELD WIRING

: TERMINAL

: CONNECTOR

: PROTECTIVE EARTH (SCREW)

BLK

: BLACK

BLU

: BLUE

RED

: RED

WHT

: WHITE

YLW

: YELLOW

Summary of Contents for FDQ125B7V3B x 2

Page 1: ...INSTALLATION MANUAL FDY125B7V1 FDY200B7V1 FDY250B7V1 FDYP125B7V1 FDYP200B7V1 FDYP250B7V1 FDQ125B7V3B Split System air conditioners ...

Page 2: ... 1 2 2 1 4 5 3 2 1 4 1440 602 125 class 840 200 250 class P1 P2 1 2 3 P2 1 2 3 L N P1 2 3 1 4 5 3 2 6 P1 P2 P1 P2 1 2 3 P2 1 2 3 L N P1 2 3 1 4 5 3 2 6 7 P1 P2 1 2 3 P2 1 2 3 L N P1 1 2 3 P2 1 2 3 L N P1 1 2 3 P2 1 2 3 L N P1 2 3 1 4 5 3 2 6 1 2 3 4 5 6 7 8 9 ...

Page 3: ...menttien vaatimuksia edellyttäen että niitä käytetään ohjeidemme mukaisesti following the provisions of Directives as amended gemäß den Vorschriften der Direktiven gemäß Änderung conformément aux stipulations des Directives telles que modifiées overeenkomstig de bepalingen van Richtlijnen zoals geamendeerd siguiendo las disposiciones de Directivas según lo enmendado secondo le prescrizioni per Dir...

Page 4: ... there is a risk reinforce the ceiling before installing the unit CHECK LIST For the following items take special care during construction and check after installation is finished FDY P 125B7V1 FDQ125B7V3B FDY P 200B7V1 FDY P 250B7V1 Split System air conditioners Installation manual READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE IMPROPE...

Page 5: ...d refrigerant The liquid line must be connected to the air conditioning unit via a flare connection The gas line must be welded directly to the air conditioning unit piping In case of a FDY125 unit both the liquid line and the gas line must be connected to the air conditioning via a flare connection In case of flare connections flare the pipe end neatly to avoid refrigerants leaks Be sure to use b...

Page 6: ...g example Pair type Refer to figure 7 Remote controller controls 1 indoor unit standard system Control by two remote controllers Refer to figure 8 Two remote controllers control 1 indoor unit Group control Refer to figure 9 Remote controller controls up to 16 indoor units All indoor units operate according to the remote controller The drain hose must slope downward to the outdoor side Never put th...

Page 7: ...de n according to the table to enable or disable the remote sensor TEST OPERATION Refer to Check list on page 1 After finishing the construction of refrigerant piping drain piping and electric wiring conduct test operation accordingly to protect the unit 1 Open the gas side stop valve 2 Open the liquid side stop valve 3 Electrify crank case heater for 6 hours 4 Set to cooling operation with the re...

Page 8: ...l adaptor X30A Connector interface adaptor for Sky Air series only for FDY P 125 250 X33A Connector Adaptor for wiring X40A Connector remote on off forced off X60A X61A Connector interface adaptor for Sky Air series only for FDQ Wired remote controller BS2 Timer mode start stop button BS7 Timer on off button BS3 BS8 Programming timer button BS1 ON OFF button BS4 Temperature setting button up BS6 O...

Page 9: ...NOTES NOTES ...

Page 10: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN10621 1C ...

Reviews: