Wall Mounted and LSP Duct Type Functions
SiSG121917E
57
Part 4 Functions and Control
1.14 WEEKLY TIMER Operation
Applicable
Models
CTKS25/35/50/60/71TVMG
CTKB25/35/50/60TVMG
Outline
Up to 4 timer settings can be saved for each day of the week (up to 28 settings in total).
The 3 items: ON/OFF, temperature, and time can be set.
Details
Setting example of the WEEKLY TIMER
6:00
8:30
17:30
22:00
25°C
27°C
ON
ON
OFF
OFF
Program 1
Program 2
Program 3
Program 4
ON
OFF
ON
OFF
6:00
8:30
17:30
22:00
25°C
27°C
Program 1
Program 2
Program 3
Program 4
ON
OFF
ON
OFF
Make timer settings for programs 1-4.
8:00
10:00
19:00
21:00
27°C
27°C
25°C
ON
ON
OFF
OFF
ON
OFF
OFF
ON
Program 1
Program 2
Program 3
Program 4
• Up to 4 reservations per day and 28 reservations per week can be set using the WEEKLY TIMER. The effective use of the
copy mode simplifies timer programming.
• The use of ON-ON-ON-ON settings, for example, makes it possible to schedule operating mode and set temperature
changes. Furthermore, by using OFF-OFF-OFF-OFF settings, only the turn off time of each day can be set. This will turn
off the air conditioner automatically if you forget to turn it off.
The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend.
[Monday]
Make timer settings for programs 1-4.
[Tuesday]
to
[Friday]
[Saturday]
[Sunday]
Use the copy mode to make settings for Tuesday to Friday, because these settings are the same as
those for Monday.
No timer settings