Daikin FDA200AXVEB Installation And Operation Manual Download Page 3

Table of Contents

Installation and operation manual

3

250AXVEB
Split system air conditioners
3P580564-1 – 2019.04

Table of Contents

1 About the documentation

3

1.1

About this document..................................................................

3

For the installer

4

2 About the box

4

2.1

Indoor unit .................................................................................

4

2.1.1

To remove the accessories from the indoor unit.........

4

3 About the units and options

4

3.1

System layout ............................................................................

4

4 Preparation

4

4.1

Preparing the installation site ....................................................

4

4.1.1

Installation site requirements of the indoor unit ..........

4

5 Installation

5

5.1

Mounting the indoor unit............................................................

5

5.1.1

Guidelines when installing the indoor unit...................

5

5.1.2

Guidelines when installing the drain piping.................

5

5.1.3

Guidelines when installing the ducting........................

6

5.2

Connecting the refrigerant piping ..............................................

7

5.2.1

To connect the refrigerant piping to the indoor unit ....

7

5.3

Connecting the electrical wiring.................................................

7

5.3.1

Specifications of standard wiring components............

8

5.3.2

To connect the electrical wiring on the indoor unit......

8

6 Commissioning

9

6.1

Checklist before commissioning ................................................

9

6.2

To perform a test run .................................................................

9

7 Configuration

9

7.1

Field setting ...............................................................................

9

8 Disposal

10

9 Technical data

10

9.1

Wiring diagram ..........................................................................

10

9.1.1

Unified wiring diagram legend..................................... 10

For the user

11

10 About the system

11

10.1

Components ..............................................................................

12

11 User interface

12

12 Operation

12

12.1

Operation range ........................................................................

12

12.2

Operation procedure .................................................................

12

13 Maintenance and service

12

13.1

Overview: Maintenance and service .........................................

12

13.2

Cleaning the air filter and air outlet............................................

13

13.2.1

To clean the air outlet ................................................. 13

13.2.2

To clean the air filter ................................................... 13

13.3

Maintenance before a long stop period .....................................

13

13.4

Maintenance after a long stop period ........................................

13

13.5

About the refrigerant..................................................................

14

14 Troubleshooting

14

14.1

Symptoms that are NOT system malfunctions ..........................

15

14.1.1

Symptom: The system does not operate .................... 15

14.1.2

Symptom: White mist comes out of a unit (Indoor
unit) ............................................................................. 15

14.1.3

Symptom: Noise of air conditioners (indoor unit) ......... 15

14.1.4

Symptom: Dust comes out of the unit .......................... 15

14.1.5

Symptom: The units can give off odours...................... 15

14.1.6

Symptom: The display shows "88"............................... 15

14.1.7

Symptom: The operation stopped suddenly
(Operation lamp is on) ................................................. 15

14.1.8

Symptom: The outdoor fan rotates while the air
conditioner is not in operation ...................................... 15

14.1.9

Symptom: The heating operation stops suddenly and
a flowing sound is heard .............................................. 15

15 Disposal

16

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised inst end users

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied materials follow the instructions from Daikin and, in
addition,  comply  with  applicable  legislation  and  are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation and operation manual:

▪ Installation and operation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer and user reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

extranet (authentication required).

Summary of Contents for FDA200AXVEB

Page 1: ...Installation and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FDA200AXVEB FDA250AXVEB...

Page 2: ...na imi navodili on vastavuses j rgmis t e standardi te ga v i teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus normi...

Page 3: ...Symptom The units can give off odours 15 14 1 6 Symptom The display shows 88 15 14 1 7 Symptom The operation stopped suddenly Operation lamp is on 15 14 1 8 Symptom The outdoor fan rotates while the a...

Page 4: ...er bracket d Screws for duct flanges M5 12 e Hexagon head bolt M10 40 f Attached piping with sealing g Tie wrap h Spring washer 3 About the units and options 3 1 System layout INFORMATION The followin...

Page 5: ...e the ceiling before installing the unit Suspension bolts Use M10 suspension bolts for installation Attach the hanger bracket to the suspension bolt Fix it securely using a nut and washer from the upp...

Page 6: ...o the unit using a duct system make sure there are no operating ignition sources example open flames an operating gas appliance or an operating electric heater in case the floor area is less than Amin...

Page 7: ...ction attached to the unit d Indoor unit 2 Connect the gas piping using the attached piping accessory Fix it to the unit using hexagon head bolts M10 40 accessory and spring washers accessory Place se...

Page 8: ...each other In order to avoid any electrical interference the distance between both wirings should ALWAYS be at least 50 mm NOTICE Be sure to keep the power line and transmission line apart from each o...

Page 9: ...the voltage on the identification label of the unit There are NO loose connections or damaged electrical components in the switch box There are NO damaged components or squeezed pipes on the inside o...

Page 10: ...ailable on the Daikin extranet authentication required 9 1 Wiring diagram 9 1 1 Unified wiring diagram legend For applied parts and numbering refer to the wiring diagram on the unit Part numbering is...

Page 11: ...H C Buzzer C Capacitor AC CN E HA HE HL HN HR MR _A MR _B S U V W X A K R_ Connection connector For the user 10 About the system INFORMATION This appliance is intended to be used by expert or trained...

Page 12: ...nual of the installed user interface 12 Operation 12 1 Operation range For combination with R410A outdoor unit refer to the following table Outdoor units Cooling Heating RZQ200 250 Outdoor temperature...

Page 13: ...clean filter notification Clean the air filter when the notification is displayed If the dirt becomes impossible to clean change the air filter How to clean the air filter 1 Remove the screws on the...

Page 14: ...ation and shut off the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electric shock or fire Contact your dealer The system MU...

Page 15: ...the outdoor unit will stop operation and the indoor unit will operate in fan only mode low fan speed In case of multi split the indoor unit alternately operates in fan stop mode and fan only mode LL l...

Page 16: ...ers 3P580564 1 2019 04 15 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...3P580564 1 2019 04 Copyright 2019 Daikin...

Reviews: