3. OPERATION RANGE

If the temperature or the humidity is beyond the following 

conditions, safety devices may work and the air conditioner may 

not operate, or sometimes, water may drop from the indoor unit. 

COOLING 

FOR FCW 15, 18

24

, 27, 

30, 

33, 

36, 42

, 46, 

48 ARV16 

OUTDOOR 

INDOOR 

UNIT 

TEMPERA-

HUMIDITY 

TURE 

17  to 35 

CHILLER 

80% or below 

14 to 24 

DB: Dry bulb temperature (

°

C) 

WB: Wet bulb temperature (

°

C) 

The setting temperature range of the remote controller is 

16

°

C to 32

°

C. 

4. INSTALLATION SITE

Regarding places for installation 

• Is the air conditioner installed at a well-ventilated

place where there are no obstacles around?

• Do not use the air conditioner in the following places.

a. Filled with much mineral oil such as cutting oil.
b. Where there is much salt such as a beach area.

c. Where sulfured gas exists such as a hot-spring resort.

d. Where there are considerable voltage fluctuations

such as a factory or plant.

e.  Vehicles and vessels.

f. Where there is much spray of oil and vapor such as a

cookery, etc.

g. Where there are machines generating electromagnetic

waves.

h. Filled with acid and/or alkaline steam or vapor.

• Is a snow protection measure taken?

For details, consult your dealer about snow protection

hoods, etc.

Regarding wiring 

• All wiring must be performed by an authorized

electrician.

To  do wiring, ask your dealer. Never do it by yourself.

• Make sure that a separate power supply circuit is

provided for this air conditioner and that all electrical

work is carried out by qualified personnel according

to local laws and regulations.

Pay attention to running noises, too 

• If abnormal noises occur in use, stop the operation

of the air conditioner, consult your dealer.

26

System relocation 

• Consult your  Daikin dealer about remodelling and

relocation.

Regarding drainage of drain pipe 

• Is the drain pipe executed to perform complete

drainage?

If proper drainage is not carried out from the  indoor drain

pipes during air-conditioning operation, chances are that

dust and dirt are clogged in the pipe. This may result in a

water leakage from the indoor unit. Under such

circumstances, stop the operation of the air conditioner,

and then consult your dealer or our service station.

5. OPERATION PROCEDURE

• To protect the unit, turn on the main power supply switch

6 hours before operation.

• Do not shut off the power supply during seasonal use of

the air conditioner.

This is required in order to activate the air conditioner

smoothly.

• If the main power supply switch is turned off during

operation, operation will restart automatically after the

power turns back on again.

6. OPERATION CHARACTERISTICS

CHARACTERISTICS OF THE COOLING

OPERATION (COOLING OPERATION AND

AUTOMATIC COOLING OPERATION)

• When operating continuously at downward airflow

direction, air blows in the automatically set direction

for a period of time to prevent condensation on the

horizontal blade.

• If the COOLING OPERATION is used when the indoor

temperature is low, frost forms on the heat exchanger

of the indoor unit. This can decrease the cooling capacity.

• When the outdoor temperature is high, it takes some time

until the indoor temperature reaches the set temperature.

CHARACTERISTICS OF THE PROGRAM

DRY OPERATION

• This dry operation lowers the humidity without lowering the

indoor temperature. The indoor temperature.when the

dry operation button is pressed.will be the set temperature.

At this time, the fan speed and temperature are set

automatically,  so the remote controller does not display

the fan speed and set temperature.

To efficiently lower the indoor temperature and humidity,

first use the COOLING OPERATION to lower the indoor

temperature, and then use the PROGRAM DRY

OPERATION. When the indoor temperature is lowered,

airflow from the air conditioner may stop.

Summary of Contents for FCW15ARV16

Page 1: ...E FCW15ARV16 FCW18ARV16 FCW24ARV16 FCW27ARV16 FCW30ARV16 FCW33ARV16 FCW36ARV16 FCW42ARV16 FCW46ARV16 FCW48ARV16 Air Conditioners READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THIS MANUAL...

Page 2: ...personal injury or loss of life CAUTION Failure to observe these instructions properly may result in property damage or personal injury which may be serious depending on the circumstances WARNING Ask...

Page 3: ...ms with electronic fluorescent lamps inverter or rapid start types Install the indoor unit as far away from fluorescent lamps as possible In a domestic environment this product may cause radio interfe...

Page 4: ...salt content in the air such as beachfront property locations where the voltage fluctuates such as factories or in automobiles or marine vessels Do not install accessories on the casing directiy Dril...

Page 5: ...unit may malfunction or the components burn out Is the water leak test finished It may causes insufficient cooling Is the unit fully insulated Condensate water may drip Does drainage flow smoothly Co...

Page 6: ...x and moving it and do not exert pressure on to any other part piping water drain etc or plastic parts If the temperature or humidity inside the ceiling might rise above 30 C or RH 80 respectively use...

Page 7: ...s and radios This is to prevent image interference and noise in those electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if 1 mete...

Page 8: ...h 840 Indoor unit 860 910 Ceilin openin 950 Decoration panel f A Fig 4 Water Piping I s 1 uspens1on bolt x4 unit mm False ceiling View as seen from A Fig 5 Decoration Panel BYCQ48EAF6 C mm 125 130 Han...

Page 9: ...paper pattern for installation 5 for ceiling opening dimensions Create the ceiling opening required for installation From the side of the opening to the casing outlet and drain piping and wiring for...

Page 10: ...2 Refer to the paper pattern for installation 5 for ceiling opening dimension Consult the builder or carpenter for details The center of the ceiling opening is indicated on the paper pattern for insta...

Page 11: ...t the height and position of the unit Level Maintaining horizontality Fig 13 Refer to 4 PREPARATIONS BEFORE INSTALLATION 1 and 1 3 in 1 For new ceilings 2 3 Perform steps 1 4 1 5 in 1 For new ceilings...

Page 12: ...r installation Some main fitting components are needed in the system to enhance the capacity and ease the service such as gate valve balancing valve 2 ways or 3 ways valve filter strainer etc During s...

Page 13: ...ccessory Level or 1 i_ _3 7 t tilted 1 slightly up To prevent air bubbles in the drain hose part keep it level or 1 slightly tilted up Any bubbles in I the hose might cause the unit to 1 make noise du...

Page 14: ...INGLE PHASE 230V to connections No 1 and No 2 on the terminal block for wiring the units Do not connect to No 3 of the terminal block for wiring the units The drain pump will not operate Connect the e...

Page 15: ...uld be about 100mm long Service drain outlet with rubber plug Use this outlet to drain water from the drain pan Adding water through air discharge outlet Method of adding water Power supply I single p...

Page 16: ...loroprene sheathed flexible cord code designation 60245 IEC 57 3 Vinyl cord with sheath or cable Insulated thickness 1 mm or more Connection of wiring between units earth wire Wiring the units and ear...

Page 17: ...____ __ _ Clamp 4 Eifrth wire E E 0 0 T I 0 co Ctl c ci5 E E 8 LC T 1 Ctl 0 Jg T 15 wire Cut off any excess material after tightening the inter unit wiring and earth wire 1 1 together Earth terminal I...

Page 18: ...s and fix the wires so that external forces are not applied to the terminals Attach insulation sleeve Round crimp style terminal Connect wires of the same gauge to both side GOOD Good Fig 26 Do not co...

Page 19: ...run explain the customer not to operate the air conditioner This is essential until the interior work is finished so as to protect the product Substances generated from paints and adhesives used for...

Page 20: ...ARV16 FCW18ARV16 FCW24ARV16 FCW27ARV16 FCW30ARV16 FCW33ARV16 FCW36ARV16 FCW42ARV16 FCW46ARV16 FCW48ARV16 OPERATION MANUAL Air Conditioners English READ THESE INSTRUCTION CAREFULLY BEFORE USE KEEP THIS...

Page 21: ...fully read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs This manual explains about the indoor unit only After...

Page 22: ...ne by a qualified installer in accordance with relevant local and national legislation Air conditioners must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring...

Page 23: ...fire hazards Consult your local dealer regarding modification repair and maintenance of the air conditioner Improper workmanship may result in water leakage electric shocks or fire hazards Do not pla...

Page 24: ...cause deformation 24 Do not block air inlets or outlets Impaired air flow may result in insufficient performance or trouble Be sure that children plants or animals are not exposed directly to airflow...

Page 25: ...ON OFF Button 7 Segment Display IDU Coil Sensor Orange LED Timer Operation Green LED Operation Lamp Red LED Infra Red Reciever 25...

Page 26: ...ge of drain pipe Is the drain pipe executed to perform complete drainage If proper drainage is not carried out from the indoor drain pipes during air conditioning operation chances are that dust and d...

Page 27: ...the following precautions to ensure the system operates Adjust the room temperature properly for a comfortable environment Avoid excessive cooling Prevent direct sunlight from entering a room during...

Page 28: ...up water leakage HOW TO CLEAN THE AIR FILTER When the remote controller indicates Time to clean filter clean the air filter It indicates after running for a certain time NOTE a You may change the time...

Page 29: ...the cloth in the neutral detergent diluted with water and twist the cloth After wiping off stain with this cloth wipe them with dry cloth NOTE Di Do not use such as gasoline benzene thinner polishing...

Page 30: ...ow to install remove or clean an optional sold air filter refer to the user s manual attached to the air filter NOTE g The inside of the air conditioner may become contaminated after several seasons o...

Page 31: ...dew condensation at the air outlet Refer to 8 MAINTENANCE on page 6 31 3 The air conditioner operates but it does not sufficiently cool Check if the air inlet or outlet of indoor unit is blocked by ob...

Page 32: ...fan PCB If the connection is normal replace the fan motor If this still cannot solve the error replace the fan PCB Need to reset unit for reset the error Power supply voltage error of the fan PCB has...

Page 33: ...operation ECONO operation enables efficient operation by limiting the maximum power consumption Press this button once to start the ECONO operation Set temperature is 26 C Fixed and fan speed is set...

Page 34: ...Operation Low Fixed COOL Operation cAuto Low Low Medium Medium Medium High High 7 FAN Operation cLow Low Medium Medium Medium High High 7 12 ON TIMER button ON Timer function is useful for automatical...

Page 35: ...DAIKIN AIRCONDIT ONING INDIA PVT LTD 12th floor Building No 9 Tower A DLF Cyber City DLF Phase Ill Gurgaon 122002 Haryana India Tel 0124 4555444 Fax 0124 4555333 3P731020 1 35...