Name and function of each switch and display on

the remote control

1

ON/OFF BUTTON

Press the button and the system will start. Press the button again and the system will stop.

2

OPERATION LAMP (RED)

The lamp lights up during operation.

3

DISPLAY ’

h

’ (UNDER CENTRALISED CONTROL)

When this display shows, the system is UNDER CENTRALISED CONTROL. (This is not a standard

specification).

4

DISPLAY ’

’ (CHANGEOVER UNDER CONTROL)

It is impossible to changeover heat/cool with the remote controller when this icon is displayed.

5

DISPLAY ’’

’’, ’’

’’, ’’

’’, ’’

’’, ’’

’’ (VENTILATION /

AIR CLEANING)

This display shows that the total heat exchange unit and the air cleaning unit are in operation.

These are optional accessories.

6

DISPLAY ’

A

’ ’

I

’ ’

,

’ ’

u

’ ’

w

’ (OPERATION MODE)

This display shows the current OPERATION MODE. For cooling only type, ’

,

’ (Auto) and ’

w

(Heating) are not installed.

7

DISPLAY ’

b

’ (INSPECTION/TEST OPERATION)

When the INSPECTION/TEST OPERATION BUTTON is pressed, the display shows the mode in which

the system actually is.

8

DISPLAY ’

I

’ (PROGRAMMED TIME)

This display shows PROGRAMMED TIME of the system start or stop.

9

DISPLAY ’

O

’ (SET TEMPERATURE)

This display shows the set temperature.

10

DISPLAY ’

B C

’(FAN SPEED)

The display shows the set fan speed.

11

DISPLAY ’

a

’ (AIR FLOW FLAP)

12

DISPLAY ’’

’’ (TIME TO CLEAN AIR FILTER)

13

DISPLAY ’’

’’ (DEFROST)

14

TIMER MODE START/STOP BUTTON

15

TIMER ON/OFF BUTTON

16

INSPECTION/TEST OPERATION BUTTON

This button is used only by qualified service persons for maintenance purposes.

17

PROGRAMMING TIME BUTTON

Use this button for programming ’START and/or STOP’ time.

18

TEMPERATURE SETTING BUTTON

Use this button for SETTING TEMPERATURE.

19

FILTER SIGN RESET BUTTON

20

FAN SPEED CONTROL BUTTON

Press this button to select the fan speed, HIGH or LOW, of your choice.

21

OPERATION MODE SELECTOR BUTTON

Press this button to select OPERATION MODE.

22

AIR FLOW DIRECTION ADJUST BUTTON

23

OPERATION MODE/FAN SPEED (only for HRV units) Refer to the manual

of VAM units for more details.

(NOTE)

+

For the sake of explanation, all indications are shown on the display in

the figure contrary to actual running situations.

4-Way Blow Ceiling Mounted Cassette

R-410A

FCQ35-60B7V1B

9

Control systems

9-1

Wired remote control

9

9-1

16

Split - Sky Air

Indoor Units

Summary of Contents for FCQ35B7V1

Page 1: ...FCQ B7 4 way Blow Ceiling Mounted Casette technical data Split Sky Air air conditioning systems...

Page 2: ...products and services and to assist in maintaining and improving the quality of the environment Daikin Europe N V is approved by LRQA for its Quality Management System in accordance with the ISO9001...

Page 3: ...ing diagrams 6 5 Wiring diagrams 7 6 Sound level 8 Sound level data Sound pressure spectrum 7 Air flow patterns 9 8 Accessories 12 Optional accessories 9 Control systems 15 10 Center of gravity 17 11...

Page 4: ...nits are individually controllable with remote control and do not need to be installed in the same room The wired remote control has a programmable timer Centralised control of several units can be ac...

Page 5: ...ng C E E Heating D C D ANNUAL ENERGY CONSUMPTION Cooling kW h 605 960 1 095 TECHNICAL SPECIFICATIONS For indoor units only INDOOR UNITS FCQ35B7V1 FCQ50B7V1 FCQ60B7V1 DIMENSIONS Unit H mm 230 W mm 840...

Page 6: ...SUPPLY V1 V1 V1 NOMINAL DISTRIBUTION SYSTEM VOLTAGE Phase 1 1 1 Frequency Hz 50 50 50 Voltage V 230 230 230 3TW25081 1 NOTES 1 Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB...

Page 7: ...cover 10 Drain hose O D J32 Required installation space When the discharge grill is closed the required space is 200mm or more 860 890 Ceiling opening Adjustable 0 550 Hanging bolt 1000 mm or more Re...

Page 8: ...Heat exchanger Refrigerant flow Cooling Heating Liquid pipe connection port 3TW20435 1H FCQ B7 Gas pipe connection port Filter Refrigerant pipe connection port diameters Model Gas Liquid FCQ35B J9 52...

Page 9: ...tch main sub SS2 Selector switch wireless address set Indoor Outdoor Wired remote control Terminals for operation indicator Note 3 Receiver display unit Adapter for wiring Fan operation compressor ope...

Page 10: ...ir discharge in 4 directions 2 The operation noise differs with the operation and ambient conditions 3 dBA A weighted sound pressure level A scale according to IEC 4 Reference acoustic pressure 0dB 20...

Page 11: ...locity distribution 4 way discharge air flow direction down FCQ35B7 Heating air temperature distribution 4 way discharge air flow direction down 4D024116 4 Way Blow Ceiling Mounted Cassette R 410A FCQ...

Page 12: ...4 way discharge air flow direction down FCQ50B7 Heating air temperature distribution 4 way discharge air flow direction down 4D024117 4 Way Blow Ceiling Mounted Cassette R 410A FCQ35 60B7V1B 7 Air flo...

Page 13: ...4 way discharge air flow direction down FCQ60B7 Heating air temperature distribution 4 way discharge air flow direction down 4D024118 4 Way Blow Ceiling Mounted Cassette R 410A FCQ35 60B7V1B 7 Air flo...

Page 14: ...per pattern for installation 1 pc Drain hose 1 pc Screws M5 For paper pattern for installation 4 pcs Washer for hanging bracket 8 pcs Sealing 2 pcs Insulation for fitting 1 of each For gas pipe For li...

Page 15: ...55X160 Sealing member of air discharge outlet KDBHJ55B160 Panel spacer KDBJ55K160W Branch duct chamber KDJ55B80 Chamber connection kit KKSJ55K160 Control systems Item Model FCQ35 FCQ50 FCQ60 Infrared...

Page 16: ...volume can be sucked from the fresh air duct The use of a duct fan is not allowed because the sound of the duct can be heard at the indoor unit Option kit Fresh air intake volume static pressure Stat...

Page 17: ...9 Control systems 9 1 Wired remote control BRC1C517 Fig 1 BRC1C517 4 Way Blow Ceiling Mounted Cassette R 410A FCQ35 60B7V1B 9 9 1 15 Split Sky Air Indoor Units...

Page 18: ...isplay shows PROGRAMMED TIME of the system start or stop 9 DISPLAY O SET TEMPERATURE This display shows the set temperature 10 DISPLAY B C FAN SPEED The display shows the set fan speed 11 DISPLAY a AI...

Page 19: ...vice settings Model Safety devices 35 45 60 FCQ B Fan motor thermal protector C OFF 130 5 ON 80 20 OFF 130 5 ON 80 20 OFF 130 5 ON 80 20 Drain pump fuse C 145 145 145 3TW22831 3A FCQ B7 4 Way Blow Cei...

Page 20: ...Remote controller 4 Inlet air 5 Discharged air 6 Refrigerant piping connection electric wire 7 Drain pipe 8 Ground wire Wire to ground from the outdoor unit to prevent electrical shocks 4 Way Blow Cei...

Reviews: