background image

5

Wiring diagrams

3TW25086-1

FCQ-B7

33H

Float switch

A1P

Printed circuit board

C1R

Capacitor (M2F)

HAP

Light emitting diode (service monitor green)

M1A

Motor (swing flap)

M2F

Motor (indoor fan)

M3P

Motor (drain pump)

Q1F

Thermo switch (M2F embedded)

R1T

Thermistor (air)

R2T

Thermistor (liquid)

R3T

Thermistor (coil)

RyP

Magnetic relay (M3P)

SS1

Selector switch (emergency)

T1R

Transformer (220-240V/22V)

X1M

Terminal strip (power)

X2M

Terminal strip (control)

PC

Phase control circuit

RC

Signal receiver circuit

TC

Signal transmission circuit

Wired remote control

SS1

Selector switch (main/sub)

Receiver / display unit (attached to infrared remote control)

A2P,A3P Printed circuit board

BS

Push button (on/off)

H1P

Light emitting diode (on-red)

H2P

Light emitting diode (timer-green)

H3P

Light emitting diode (filter sign-red)

H4P

Light emitting diode (defrost-orange)

SS1

Selector switch (main/sub)

SS2

Selector switch (wireless address set)

Indoor

Outdoor

Wired remote

control

Terminals for operation indicator

Note 3

Receiver / display unit

Adapter for

wiring

Fan operation

compressor operation

Notes
1. Use copper conductors only.

2. When using the central remote control, see manual for

connection to the unit.

3. X24A is connected when the remote control kit is used.

4. The infrared remote controller model varies according to

the combination system. See technical data and catalogs

before connecting.

g

Field wiring

D

Terminal

F

: Connector

h

: Wire clamp

b

: Protective earth (screw)

Colours

BLK: Black / WHT: White / RED: Red / YLW: Yellow

Adapter for wiring

RyC,RyF

Magnetic relay

Connector for optional parts

X60A,X61A Connector (interface adapter for sky air series)

X33A

Connector (adapter for wiring)

X35A

Connector (group control adapter)

X40A

Connector (remote ON/OFF forced OFF)

Switch box

Simultaneous operation system

Remote

controller

Master

Slave

Outdoor

unit

4-Way Blow Ceiling Mounted Cassette

R-410A

FCQ35-60B7V1B

5

7

Split - Sky Air

Indoor Units

Summary of Contents for FCQ35B7V1

Page 1: ...FCQ B7 4 way Blow Ceiling Mounted Casette technical data Split Sky Air air conditioning systems...

Page 2: ...products and services and to assist in maintaining and improving the quality of the environment Daikin Europe N V is approved by LRQA for its Quality Management System in accordance with the ISO9001...

Page 3: ...ing diagrams 6 5 Wiring diagrams 7 6 Sound level 8 Sound level data Sound pressure spectrum 7 Air flow patterns 9 8 Accessories 12 Optional accessories 9 Control systems 15 10 Center of gravity 17 11...

Page 4: ...nits are individually controllable with remote control and do not need to be installed in the same room The wired remote control has a programmable timer Centralised control of several units can be ac...

Page 5: ...ng C E E Heating D C D ANNUAL ENERGY CONSUMPTION Cooling kW h 605 960 1 095 TECHNICAL SPECIFICATIONS For indoor units only INDOOR UNITS FCQ35B7V1 FCQ50B7V1 FCQ60B7V1 DIMENSIONS Unit H mm 230 W mm 840...

Page 6: ...SUPPLY V1 V1 V1 NOMINAL DISTRIBUTION SYSTEM VOLTAGE Phase 1 1 1 Frequency Hz 50 50 50 Voltage V 230 230 230 3TW25081 1 NOTES 1 Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB...

Page 7: ...cover 10 Drain hose O D J32 Required installation space When the discharge grill is closed the required space is 200mm or more 860 890 Ceiling opening Adjustable 0 550 Hanging bolt 1000 mm or more Re...

Page 8: ...Heat exchanger Refrigerant flow Cooling Heating Liquid pipe connection port 3TW20435 1H FCQ B7 Gas pipe connection port Filter Refrigerant pipe connection port diameters Model Gas Liquid FCQ35B J9 52...

Page 9: ...tch main sub SS2 Selector switch wireless address set Indoor Outdoor Wired remote control Terminals for operation indicator Note 3 Receiver display unit Adapter for wiring Fan operation compressor ope...

Page 10: ...ir discharge in 4 directions 2 The operation noise differs with the operation and ambient conditions 3 dBA A weighted sound pressure level A scale according to IEC 4 Reference acoustic pressure 0dB 20...

Page 11: ...locity distribution 4 way discharge air flow direction down FCQ35B7 Heating air temperature distribution 4 way discharge air flow direction down 4D024116 4 Way Blow Ceiling Mounted Cassette R 410A FCQ...

Page 12: ...4 way discharge air flow direction down FCQ50B7 Heating air temperature distribution 4 way discharge air flow direction down 4D024117 4 Way Blow Ceiling Mounted Cassette R 410A FCQ35 60B7V1B 7 Air flo...

Page 13: ...4 way discharge air flow direction down FCQ60B7 Heating air temperature distribution 4 way discharge air flow direction down 4D024118 4 Way Blow Ceiling Mounted Cassette R 410A FCQ35 60B7V1B 7 Air flo...

Page 14: ...per pattern for installation 1 pc Drain hose 1 pc Screws M5 For paper pattern for installation 4 pcs Washer for hanging bracket 8 pcs Sealing 2 pcs Insulation for fitting 1 of each For gas pipe For li...

Page 15: ...55X160 Sealing member of air discharge outlet KDBHJ55B160 Panel spacer KDBJ55K160W Branch duct chamber KDJ55B80 Chamber connection kit KKSJ55K160 Control systems Item Model FCQ35 FCQ50 FCQ60 Infrared...

Page 16: ...volume can be sucked from the fresh air duct The use of a duct fan is not allowed because the sound of the duct can be heard at the indoor unit Option kit Fresh air intake volume static pressure Stat...

Page 17: ...9 Control systems 9 1 Wired remote control BRC1C517 Fig 1 BRC1C517 4 Way Blow Ceiling Mounted Cassette R 410A FCQ35 60B7V1B 9 9 1 15 Split Sky Air Indoor Units...

Page 18: ...isplay shows PROGRAMMED TIME of the system start or stop 9 DISPLAY O SET TEMPERATURE This display shows the set temperature 10 DISPLAY B C FAN SPEED The display shows the set fan speed 11 DISPLAY a AI...

Page 19: ...vice settings Model Safety devices 35 45 60 FCQ B Fan motor thermal protector C OFF 130 5 ON 80 20 OFF 130 5 ON 80 20 OFF 130 5 ON 80 20 Drain pump fuse C 145 145 145 3TW22831 3A FCQ B7 4 Way Blow Cei...

Page 20: ...Remote controller 4 Inlet air 5 Discharged air 6 Refrigerant piping connection electric wire 7 Drain pipe 8 Ground wire Wire to ground from the outdoor unit to prevent electrical shocks 4 Way Blow Cei...