If the PROGRAM DRY OPERATION is used 
when the indoor temperature is low, frost forms 
the heat exchanger of the indoor unit. In this case, 
the air conditioner automatically switches to the 
DEFROST OPERATION for a while. 
The low fan speed or a gentle wind is used to 
prevent the discharge of melt water.

 

„

SOUND PRESSURE LEVEL

• 

Sound pressure level is less than 70 dB(A).

7.  OPTIMUM OPERATION

Observe the following precautions to ensure the air 
conditioner operates.

• 

Prevent direct sunlight from the window by 
using curtains or blinds during the COOLING 
OPERATION.

• 

Keep doors and windows closed. If the doors and 
windows remain open, room air will flow out and 
decrease the effect of cooling and heating.

• 

Never place objects near the air inlet and the air 
outlet of the air conditioner. It may decrease the 
effect or stop the operation.

• 

Set the airflow flap of the air discharge grille 
horizontally not to obstruct the wind. 
Otherwise, the wind will not come out and a 
failure may result.

• 

Adjust the room temperature properly for a 
comfortable environment. Avoid excessive 
heating or cooling. 
Not doing so wastes electricity.

• 

When the display shows “ 

 ” or “Time to clean 

filter”, ask a qualified service person to clean the 
filters. 
(Refer to 

8. MAINTENANCE

 on this page.) 

Operating the indoor unit with stained air filter 
may decrease capacity or cause malfunction.

• 

Install TVs, radios, and stereos 1 m or more away 
from the indoor unit and remote controller. 
Images may become fuzzy and noise may be 
generated.

• 

Turn off the power circuit breaker when it is not 
in use for a long period. When the power circuit 
breaker is turned on, small amount of power is 
consumed even if the air conditioner is not in 
operation. (*1) 
Turn off the power circuit breaker for saving 
energy. When reoperating, turn on the power 
circuit breaker 6 hours before operation for 
smooth running. 
(Refer to 

8. MAINTENANCE

 on this page.) (*2)

*1  

The consumed power while the outdoor unit is 
not in operation depends on the model.

*2  

The setting before the power circuit breaker is 
cut off is stored. (The timer setting is cleared.)

• 

Use the TIMER OPERATION effectively. 
It takes some time until the indoor temperature 
reaches the set temperature. It is advisable to 
start operation in advance using the TIMER 
OPERATION.

8.  MAINTENANCE 

(FOR SERVICE PERSONNEL)

ONLY A QUALIFIED SERVICE PERSON IS 

ALLOWED TO PERFORM MAINTENANCE

 WARNING

•  Do not use flammable gas (such as hair 

sprays and insecticides) near the air condi-

tioner.

• 

Do not wipe the air conditioner with benzine 

or thinner. 

It may cause cracks, electric shocks or a fire.

 CAUTION

• 

Do not wash the air conditioner with water. 

It may cause electric shocks or a fire due to 

leakage.

• 

Make sure to turn off the air conditioner when 

taking care of the air conditioner and discon-

nect the power supply breaker. 

Unless the power supply is disconnected, it 

may cause electric shocks and injuries.

• 

When working at a high place, give caution to 

your footing. 

If the scaffold is unstable, it may cause inju-

ries due to fall and stumbling.

HOW TO CLEAN THE AIR FILTER

When the remote controller indicates “ 

 ” or 

“Time to clean filter”, clean the air filter.

• 

It indicates after running for a certain time.

English

01_EN_3P338600-20E.indd   7

15/03/10   11:14:43 AM

Summary of Contents for FBQ60EVE4

Page 1: ...MODELS Ceiling mounted Duct type FBQ50EVE4 FBQ60EVE4 FBQ71EVE4 FBQ100EVE4 FBQ125EVE4 FBQ140EVE4 OPERATION MANUAL SPLIT SYSTEM Air Conditioner English Bahasa Indonesia...

Page 2: ...all only be done by persons described in manual The appliance is not intended for use by unattended young children or persons who are incompetent to operate air conditioners It may result in injury or...

Page 3: ...y result due to contact with the air conditioner s highspeed fan blades Consult your local dealer regarding cleaning the inside of the air conditioner Improper cleaning may cause breakage of plastic p...

Page 4: ...e with wet hands Never touch the internal parts of the remote controller Touching certain internal parts will cause electric shocks and damage to the remote controller Consult your local dealer about...

Page 5: ...rols up to 16 indoor units All indoor units are equally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor uni...

Page 6: ...tion hoods etc Regarding wiring All wiring must be performed by a qualified personnel To do wiring ask your local dealer Never do it by yourself Make sure that a separate power supply cir cuit is prov...

Page 7: ...outdoor unit increase heating effect decreases and the air conditioner goes into the DEFROST OPERATION The indoor unit fan stops and the remote controller display shows With the wireless remote contr...

Page 8: ...ed Turn off the power circuit breaker when it is not in use for a long period When the power circuit breaker is turned on small amount of power is consumed even if the air conditioner is not in operat...

Page 9: ...air conditioner will be degraded if the air filter is clogged with dust or dirt After completing cleaning and installing an air filter turn off the indication of or AIR FILTER CLEANINGTIME on the remo...

Page 10: ...he following symptoms do not indicate air conditioner malfunction HEATING OPERATION within 6 hours after the power is supplied to the air conditioner Some models perform the following operation to pro...

Page 11: ...or the PROGRAM DRY OPERATION When the room temperature reaches the set temperature during the HEATING OPERATION the outdoor unit stops and the indoor unit goes into gentle wind It takes some time unti...

Page 12: ...curs during operation the air conditioner auto matically restarts immediately after the power supply recovers 2 If the air conditioner stops after operating the air conditioner Check if the air inlet...

Page 13: ...tten on the model name plate If one of the following malfunctions occurs take the measures shown below and contact your local dealer The air conditioner must be repaired by a qualified service person...

Page 14: ...600 20K EM14A020A Gedung Wisma Keiai Lantai 18 dan 19 Jl Jend Sudirman Kav 3 Karet Tengsin Tanah Abang Jakarta Pusat DKI Jakarta 10220 Main Line Hunting 62 21 572 4377 Fax Line 62 21 572 4366 http www...

Reviews: