background image

The above operation is performed not only 
at the time of installation, but every time the 
power circuit breaker is turned off/on.
For comfortable use, do not turn off the 
power circuit breaker during seasonal use of 
the HEATING OPERATION.

• 

The outdoor unit stops.

This is because the indoor temperature has 
reached the set temperature.
The indoor unit is in the FAN OPERATION.

COOLING OPERATION 
(AUTOMATIC COOLING OPERATION):
Lower the set temperature.
HEATING OPERATION 
(AUTOMATIC HEATING OPERATION):
Raise the set temperature.

The operation starts after a while when the 
air conditioner is in normal condition.

• 

The remote controller displays “

 

 

”, 

and airflow stops.

This is because the air conditioner 
automatically switches to the DEFROST 
OPERATION to prevent a decrease in 
heating capacity when frost on the outdoor 
unit increases.
After maximum 10 minutes, the air 
conditioner returns to its original operation.

II.  THE OPERATION SOMETIMES STOPS

• 

The remote controller displays “U4” and 

“U5”, and the operation stops. However, 

it will restart in a few minutes.

This is because communication between the 
indoor and outdoor units or indoor units and 
remote controllers is shut off and stops the 
operation due to noise caused by devices 
other than the air conditioner.
When the electrical noise decreases, the air 
conditioner automatically restarts.

III.  THE FAN SPEED IS DIFFERENT FROM THE 

SETTING

• 

Pressing the fan speed control button 

does not change the fan speed.

During the COOLING OPERATION, the low 
fan speed or a gentle wind is used to prevent 
the discharge of melt water.
During the DEFROST OPERATION 
(HEATING OPERATION), the wind from the 
air conditioner stops to prevent air discharge 
directly toward your body.
After a while, the fan speed can be changed.
(The fan speed cannot be set for the 
PROGRAM DRY OPERATION.)
When the room temperature reaches the 
set temperature during the HEATING 
OPERATION, the outdoor unit stops and the 
indoor unit goes into gentle wind.

It takes some time until the fan speed 
changes. Raise the set temperature. After a 
while, the fan speed changes.

IV.  WHITE MIST COMES OUT OF THE AIR 

CONDITIONER

• 

When humidity is high during the COOL-

ING OPERATION (In oily or dusty places)

If the inside of an indoor unit is extremely 
contaminated, the temperature distribution 
inside a room becomes uneven. It is neces-
sary to clean the inside of the indoor unit.
Ask your local dealer for details on cleaning 
the indoor unit.
This cleaning requires a qualified service 
person.
Check the usage environment.

• 

When the air conditioner is changed over 

to the HEATING OPERATION after the 

DEFROST OPERATION and in the DE-

FROST OPERATION.

Moisture generated by defrost becomes 
steam and will float around.
When the remote controller display shows 

“ 

 ”, DEFROST OPERATION is being 

used.

V.  NOISE OF AIR CONDITIONERS

•  A low continuous flow “Shuh” sound 

which is heard when the air conditioner 

is in the COOLING or DEFROST OPERA-

TION or a trickling sound which is heard 

when the air conditioner is in the DE-

FROST OPERATION.

This is the sound of refrigerant gas flowing 
through both indoor and outdoor units.

• 

A “Shuh” sound which is heard at the 

start or immediately after the stop of 

operation or which is heard at the start 

or immediately after the stop of the DE-

FROST OPERATION.

This is the noise of refrigerant caused by flow 
stop and flow change.
During the HEATING OPERATION, the 
air conditioner switches to the DEFROST 
OPERATION automatically.

The remote controller shows “ 

 ”.

After maximum 10 minutes, the air 
conditioner returns to its original operation.

• 

A “Pishi-pishi” squeaking sound is heard 

when the air conditioner is in operation 

or after the stop of operation.

Expansion and contraction of resin parts 
caused by temperature change makes this 
noise.

English 

10

01_EN_3P338600-20E.indd   10

15/03/10   11:14:43 AM

Summary of Contents for FBQ60EVE4

Page 1: ...MODELS Ceiling mounted Duct type FBQ50EVE4 FBQ60EVE4 FBQ71EVE4 FBQ100EVE4 FBQ125EVE4 FBQ140EVE4 OPERATION MANUAL SPLIT SYSTEM Air Conditioner English Bahasa Indonesia...

Page 2: ...all only be done by persons described in manual The appliance is not intended for use by unattended young children or persons who are incompetent to operate air conditioners It may result in injury or...

Page 3: ...y result due to contact with the air conditioner s highspeed fan blades Consult your local dealer regarding cleaning the inside of the air conditioner Improper cleaning may cause breakage of plastic p...

Page 4: ...e with wet hands Never touch the internal parts of the remote controller Touching certain internal parts will cause electric shocks and damage to the remote controller Consult your local dealer about...

Page 5: ...rols up to 16 indoor units All indoor units are equally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor uni...

Page 6: ...tion hoods etc Regarding wiring All wiring must be performed by a qualified personnel To do wiring ask your local dealer Never do it by yourself Make sure that a separate power supply cir cuit is prov...

Page 7: ...outdoor unit increase heating effect decreases and the air conditioner goes into the DEFROST OPERATION The indoor unit fan stops and the remote controller display shows With the wireless remote contr...

Page 8: ...ed Turn off the power circuit breaker when it is not in use for a long period When the power circuit breaker is turned on small amount of power is consumed even if the air conditioner is not in operat...

Page 9: ...air conditioner will be degraded if the air filter is clogged with dust or dirt After completing cleaning and installing an air filter turn off the indication of or AIR FILTER CLEANINGTIME on the remo...

Page 10: ...he following symptoms do not indicate air conditioner malfunction HEATING OPERATION within 6 hours after the power is supplied to the air conditioner Some models perform the following operation to pro...

Page 11: ...or the PROGRAM DRY OPERATION When the room temperature reaches the set temperature during the HEATING OPERATION the outdoor unit stops and the indoor unit goes into gentle wind It takes some time unti...

Page 12: ...curs during operation the air conditioner auto matically restarts immediately after the power supply recovers 2 If the air conditioner stops after operating the air conditioner Check if the air inlet...

Page 13: ...tten on the model name plate If one of the following malfunctions occurs take the measures shown below and contact your local dealer The air conditioner must be repaired by a qualified service person...

Page 14: ...600 20K EM14A020A Gedung Wisma Keiai Lantai 18 dan 19 Jl Jend Sudirman Kav 3 Karet Tengsin Tanah Abang Jakarta Pusat DKI Jakarta 10220 Main Line Hunting 62 21 572 4377 Fax Line 62 21 572 4366 http www...