FAN OPERATION .................................. “

„

 

DRY OPERATION.................................. “

The function of this program is to decrease the 
humidity in your room with the minimum tem-
perature decrease.

Micro computer automatically determines 
TEMPERATURE and FAN SPEED.

This system does not go into operation if the 
room temperature is below 16°C.

 Refer to figure 3 on page [1] 

For cooling only type, “COOLING”, “FAN” and 
“DRY” operation are able to select.

 ON/OFF

Press ON/OFF button

OPERATION lamp lights up or goes off and the sys-
tem starts or stops OPERATION.

[EXPLANATION OF HEATING OPERATION]

DEFROST OPERATION

As the frost on the coil of an outdoor unit increase, 
heating effect decreases and the system goes 
into DEFROST OPERATION.

The indoor unit fan stops and the remote control-
ler display shows “

”.

After 6 to 8 minutes (maximum 10 minutes) of 
DEFROST OPERATION, the system returns to 
HEATING OPERATION.

Regarding outside air temperature and heat-
ing capacity

The heating capacity of the air conditioner 
declines as the outside air temperature falls. In 
such a case, use the air conditioner in combina-
tion with other heating systems.

A warm air circulating system is employed, and 
therefore it takes some time until the entire room 
is warmed up after the start of operation.

An indoor fan runs to discharge a gentle wind 
automatically until the temperature inside the air 
conditioner reaches a certain level. At this time, 
the remote controller displays “

”. Leave it 

as it stands and wait for a while.

When the warm air stays under the ceiling and 
your feet are cold, we recommend that you use a 
circulator (a fan to circulate the air inside the 
room). For details, consult your dealer.

For programming TEMPERATURE and FAN 
SPEED, follow the procedure shown below.

2

ADJUSTMENT

TEMPERATURE SETTING

Press TEMPERATURE SETTING button and 
program the setting temperature.

Each time this button is pressed, setting 
temperature rises 1°C.

Each time this button is pressed, setting 
temperature lowers 1°C.

The setting is impossible for fan operation.

NOTE

The setting temperature range of the remote con-
troller is 16°C to 32°C.

FAN SPEED CONTROL

Press FAN SPEED CONTROL button.

High or Low fan speed can be selected.
The microchip may sometimes control the fan speed 
in order to protect the unit.

Operate in the following order.

The timer is operated in the following two ways.

Programming the stop time  (

) .... 

The system stops operating after the set time has 
elapsed.

Programming the start time (

) .... 

The system starts operating after the set time has 
elapsed.

The timer can be programmed a maximum of 
72 hours.

The start and the stop time can be simultaneously 
programmed.

TIMER MODE START/STOP

Press the TIMER MODE START/STOP button 
several times and select the mode on the 
display.

The display flashes.
For setting the timer stop .... “

For setting the timer start .... “

PROGRAM TIMER OPERATION

1

Summary of Contents for FBQ50BV1A

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted built in type FBQ50BV1A FBQ60BV1A FBQ71BV1A...

Page 2: ...1 1 3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 9 3 1 4 5 6 7 12 13 14 15 16 17 18 19 10 8 11 d c g b a h f e C H hr hr...

Page 3: ...ikin air condi tioner Carefully read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs After reading the manual fi...

Page 4: ...case of group control system one group of indoor units The unit is individually operated 1 WHAT TO DO BEFORE OPERA TION NOTE Contact your Daikin dealer in case of changing the combination or setting o...

Page 5: ...earth may cause electrical shock or fire A high surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an...

Page 6: ...DB 15 to 18 WB 10 to 30 DB 4 INSTALLATION SITE d Where there are considerable voltage fluctua tions such as a factory or plant e Vehicles and vessels f Where there is much spray of oil and vapor such...

Page 7: ...function If even one unit is equipped with the function the display will not appear 12 TIMER MODE START STOP BUTTON Refer to PROGRAM TIMER OPERATION hr hr C Refer to figure 1 on page 1 Operating proc...

Page 8: ...nside the air conditioner reaches a certain level At this time the remote controller displays Leave it as it stands and wait for a while When the warm air stays under the ceiling and your feet are col...

Page 9: ...objects near the air inlet and the air outlet of the unit It may cause deterioration in the effect or stop in the operation Turn off the main power supply switch when it is not used for long periods o...

Page 10: ...some watts of electricity is being used even if the sys tem is not operating Turn off the main power supply switch for saving energy The display on the remote controller will vanish when the main pow...

Page 11: ...unit blows out V THE UNITS GIVE OFF ODORS The unit absorbs the smell of rooms furniture cigarettes etc and then emits them VI THE LIQUID CRYSTAL OF THE REMOTE CON TROLLER SHOW It happens immediately a...

Page 12: ...of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle and make it well ventilated If the air filter is clogged Ask a qualified service person to clean the air filters Refer...

Page 13: ...3P156215 7K EM06A004A 0607 FS...