background image

1

CONTENTS

ILLUSTRATIONS................................................. [1]

1. WHAT TO DO BEFORE OPERATION .......... 1

2. SAFETY CONSIDERATIONS........................ 1

3. OPERATION RANGE .................................... 3

4. INSTALLATION SITE..................................... 3

5. NAME AND FUNCTION OF EACH SWITCH 

AND  DISPLAY ON THE REMOTE 

CONTROLLER............................................... 4

6. OPERATION PROCEDURE .......................... 4

7. OPTIMUM OPERATION ................................ 6

8. MAINTENANCE

(FOR SERVICE PERSONNEL) ..................... 6

9. NOT MALFUNCTION OF THE AIR 

CONDITIONER .............................................. 7

10. TROUBLE SHOOTING .................................. 8

This operation manual is for the system with stan-
dard control. Before initiating operation, contact your 
Daikin dealer for the operation that corresponds to 
your system.

If your installation has a customized control system, 
ask your Daikin dealer for the operation that corre-
sponds to your system.

Heat pump type
This system provides cooling, heating, automatic, 
program dry, and fan operation modes.

Cooling only type
This system provides cooling, program dry, and 
fan operation modes.

PRECAUTIONS FOR GROUP CONTROL 
SYSTEM OR TWO REMOTE CONTROLLERS 
CONTROL SYSTEM

This system provides two other control systems 
beside individual control (one remote controller con-
trols one indoor unit) system. Confirm the following if 
your unit is of the following control system type.

Group control system

One remote controller controls up to 16 indoor units.
All indoor units are equally set.

Two remote controllers control system

Two remote controllers control one indoor unit (In case 
of group control system, one group of indoor units)
The unit is individually operated.

1. WHAT TO DO BEFORE OPERA-

TION

NOTE

Contact your Daikin dealer in case of changing 
the combination or setting of group control and 
two remote controllers control system.

 Refer to figure 2 on page [1] 

We recommend that you read this instruction man-
ual carefully before use to gain full advantage of the 
function of the air conditioner, and to avoid malfunc-
tion due to mishandling.
This air conditioner comes under the term “appli-
ances not accessible to the general public”.

The precautions described below are WARN-
ING and CAUTION. These are very important 
precautions concerning safety. Be sure to 
observe all of them without fail.

WARNING

.. These are the matters with possi-

bilities leading to serious conse-
quences such as death or serious 
injury due to erroneous handling.

CAUTIO

N

... These are the matters with possi-

bilities leading to injury or material 
damage due to erroneous han-
dling including probabilities lead-
ing to serious consequences in 
some cases.

After reading, keep this manual at a place 
where any user can read at any time. Further-
more, make certain that this operation manual 
is handed to a new user when he takes over 
the operation.

Names and functions of parts

a

Indoor unit

b

Remote controller

c

Inlet air

d

Discharge air

e

Refrigerant piping, connection electric wire

f

Drain pipe

g

Inlet grille

h

Drain pumping out device (built-in)
Drains water removed from the room during 
cooling.

2. SAFETY CONSIDERATIONS

Summary of Contents for FBQ50BV1A

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted built in type FBQ50BV1A FBQ60BV1A FBQ71BV1A...

Page 2: ...1 1 3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 9 3 1 4 5 6 7 12 13 14 15 16 17 18 19 10 8 11 d c g b a h f e C H hr hr...

Page 3: ...ikin air condi tioner Carefully read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs After reading the manual fi...

Page 4: ...case of group control system one group of indoor units The unit is individually operated 1 WHAT TO DO BEFORE OPERA TION NOTE Contact your Daikin dealer in case of changing the combination or setting o...

Page 5: ...earth may cause electrical shock or fire A high surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an...

Page 6: ...DB 15 to 18 WB 10 to 30 DB 4 INSTALLATION SITE d Where there are considerable voltage fluctua tions such as a factory or plant e Vehicles and vessels f Where there is much spray of oil and vapor such...

Page 7: ...function If even one unit is equipped with the function the display will not appear 12 TIMER MODE START STOP BUTTON Refer to PROGRAM TIMER OPERATION hr hr C Refer to figure 1 on page 1 Operating proc...

Page 8: ...nside the air conditioner reaches a certain level At this time the remote controller displays Leave it as it stands and wait for a while When the warm air stays under the ceiling and your feet are col...

Page 9: ...objects near the air inlet and the air outlet of the unit It may cause deterioration in the effect or stop in the operation Turn off the main power supply switch when it is not used for long periods o...

Page 10: ...some watts of electricity is being used even if the sys tem is not operating Turn off the main power supply switch for saving energy The display on the remote controller will vanish when the main pow...

Page 11: ...unit blows out V THE UNITS GIVE OFF ODORS The unit absorbs the smell of rooms furniture cigarettes etc and then emits them VI THE LIQUID CRYSTAL OF THE REMOTE CON TROLLER SHOW It happens immediately a...

Page 12: ...of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle and make it well ventilated If the air filter is clogged Ask a qualified service person to clean the air filters Refer...

Page 13: ...3P156215 7K EM06A004A 0607 FS...

Reviews: