background image

3

Consult with installation contractor for 
cleaning the inside of the air conditioner.

Wrong cleaning may make the plastics parts 
broken or cause failure of water leakage or elec-
tric shock.

Do not touch the air inlet or aluminium fin of 
the air conditioner.

Otherwise, injury may be caused.

Do not place objects in direct proximity of the 
outdoor unit and do not let leaves and other 
debris accumulate around the unit.

Leaves are a hotbed for small animals which can 
enter the unit. Once in the unit, such animals can 
cause malfunctions, smoke or fire when making 
contact with electrical parts.

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.

COOLING ONLY TYPE

HEAT PUMP TYPE

D

 

B: Dry bulb temperature

WB: Wet bulb temperature
The setting temperature range of the remote con-
troller is 16°C to 32°C.

Regarding places for installation

Is the air conditioner installed at a well-venti-
lated place where there are no obstacles 
around?

Do not use the air conditioner in the following 
places.

a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring 

resort

3. OPERATION RANGE

TEMPERATURE[

°

C]

OUTDOOR

INDOOR

–5 to 46(DB)

21 to 32(DB)/

14 to 23(WB)

OPERATION

TEMPERATURE[

°

C]

OUTDOOR

INDOOR

COOLING

–5 to 46(DB)

21 to 32(DB)/

14 to 23(WB)

HEATING

–15 to 24(DB)/

–15 to 18(WB)

10 to 30(DB)

4. INSTALLATION SITE

d. Where there are considerable voltage fluctua-

tions such as a factory or plant

e. Vehicles and vessels

 

f

 

. Where there is much spray of oil and vapor 

such as a cookery, etc.

g. Where there are machines generating electro-

magnetic waves

h. Filled with acid and/or alkaline steam or vapor

Is a snow protection measure taken?

For details, consult your dealer.

Regarding wiring

All wiring must be performed by an authorized 
electrician.

To do wiring, ask your dealer. Never do it by yourself.

Make sure that a separate power supply circuit 
is provided for this air conditioner and that all 
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.

Pay attention to running noises, too

Are the following places selected?

a. A place that can sufficiently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b. A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises.

Are you sure that there are no obstacles near 
the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

If abnormal noises occur in use, consult your 
dealer.

Regarding drainage of drain piping

Is the drain piping executed to perform com-
plete drainage?

If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation, 
chances are that dust and dirt are clogged in the 
pipe. This may result in a water leakage from the 
indoor unit. Under such circumstances, stop the 
operation of the air conditioner, and then consult 
your dealer or our service station.

Summary of Contents for FBQ50BV1A

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted built in type FBQ50BV1A FBQ60BV1A FBQ71BV1A...

Page 2: ...1 1 3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 9 3 1 4 5 6 7 12 13 14 15 16 17 18 19 10 8 11 d c g b a h f e C H hr hr...

Page 3: ...ikin air condi tioner Carefully read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs After reading the manual fi...

Page 4: ...case of group control system one group of indoor units The unit is individually operated 1 WHAT TO DO BEFORE OPERA TION NOTE Contact your Daikin dealer in case of changing the combination or setting o...

Page 5: ...earth may cause electrical shock or fire A high surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an...

Page 6: ...DB 15 to 18 WB 10 to 30 DB 4 INSTALLATION SITE d Where there are considerable voltage fluctua tions such as a factory or plant e Vehicles and vessels f Where there is much spray of oil and vapor such...

Page 7: ...function If even one unit is equipped with the function the display will not appear 12 TIMER MODE START STOP BUTTON Refer to PROGRAM TIMER OPERATION hr hr C Refer to figure 1 on page 1 Operating proc...

Page 8: ...nside the air conditioner reaches a certain level At this time the remote controller displays Leave it as it stands and wait for a while When the warm air stays under the ceiling and your feet are col...

Page 9: ...objects near the air inlet and the air outlet of the unit It may cause deterioration in the effect or stop in the operation Turn off the main power supply switch when it is not used for long periods o...

Page 10: ...some watts of electricity is being used even if the sys tem is not operating Turn off the main power supply switch for saving energy The display on the remote controller will vanish when the main pow...

Page 11: ...unit blows out V THE UNITS GIVE OFF ODORS The unit absorbs the smell of rooms furniture cigarettes etc and then emits them VI THE LIQUID CRYSTAL OF THE REMOTE CON TROLLER SHOW It happens immediately a...

Page 12: ...of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle and make it well ventilated If the air filter is clogged Ask a qualified service person to clean the air filters Refer...

Page 13: ...3P156215 7K EM06A004A 0607 FS...

Reviews: