8

II. WHITE MIST COMES OUT OF A UNIT

When humidity is high during cooling opera-
tion (In oily or dusty places)

If the inside of an indoor unit is extremely contam-
inated, the temperature distribution inside a room 
becomes uneven. It is necessary to clean the 
inside of the indoor unit. Ask your Daikin dealer for 
details on cleaning the unit. This operation 
requires a qualified service person.

When the system is changed over to HEATING 
OPERATION after DEFROST OPERATION.

Moisture generated by DEFROST becomes 
steam and exists.

III.NOISE OF AIR CONDITIONERS

A ringing sound after the unit is started.

This sound is generated by the temperature regu-
lator working.
It will quiet down after about a minute.

A continuous flow “Shuh” sound is heard 
when the systems is in COOLING or DEFROST 
OPERATION.

This is the sound of refrigerant gas flowing 
through both indoor and outdoor units.

A “Shuh” sound which is heard at the start or 
immediately after the stop of operation or 
which is heard at the start or immediately after 
the stop of DEFROST OPERATION. 

This is the noise of refrigerant caused by flow stop 
and flow change.

A continuous low “Shah” sound is heard 
when the system is in COOLING OPERATION 
or at a stop.

The noise is heard when the drain pump is in 
operation.

A “Pishi-pishi” squeaking sound is heard 
when the system is in operation or after the 
stop of operation.

Expansion and contraction of plastic parts caused 
by temperature change makes this noise.

IV.DUST FROM THE UNITS

Dust may blow out from the unit after starting 
operation from long resting time.

Dust absorbed by the unit blows out.

V. THE UNITS GIVE OFF ODORS

The unit absorbs the smell of rooms, furniture, 
cigarettes, etc., and then emits them.

VI.THE LIQUID CRYSTAL OF THE REMOTE CON-

TROLLER SHOW “

It happens immediately after the main power 
supply switch is turned on.

This shows that the remote controller is in normal 
condition.
This continues temporary.

I. If one of the following malfunctions occurs, 

take the measures shown below and contact 
your Daikin dealer.

The system must be repaired by a qualified service 
person.

WARNING

When the air conditioner is in abnormal con-
ditions (smell of something burning, etc), 
turn off power, and contact your dealer

Continued operation under such circumstances 
may result in a failure, electric shock, and fire.

If a safety device such as a fuse, a breaker, or an 
earth leakage breaker frequently actuates;

Measure: 

 Do not turn on the main power switch.

If the ON/OFF switch does not properly work;

Measure: 

 Turn off the main power switch

If water leaks from unit.

Measure:

  Stop the operation.

If the display “ 

 ” (INSPECTION), “UNIT No.”, 

and the OPERATION lamp flash and the “MAL-
FUNCTION CODE” appears.

Measure:

 Notify your Daikin dealer and inform

                 him/her of the display.

II. If the system does not properly operate except 

for the above mentioned case, and none of the 
above mentioned malfunctions is evident, 
investigate the system according to the fol-
lowing procedures.

1.

If the system does not operate at all.

Check if there is a power failure.
Wait until power is restored. If power failure 
occurs during operation, the system automati-
cally restarts immediately after the power sup-
ply recovers.

Check if no fuse has blown.
Turn off the power supply.

10. TROUBLE SHOOTING

OPERATION lamp

INSPECTION 
display

MALFUNCTION CODE

INDOOR UNIT No. in 
which a malfunction occurs

UNIT   No.

C

L

  H     

Summary of Contents for FBQ50BV1A

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted built in type FBQ50BV1A FBQ60BV1A FBQ71BV1A...

Page 2: ...1 1 3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 9 3 1 4 5 6 7 12 13 14 15 16 17 18 19 10 8 11 d c g b a h f e C H hr hr...

Page 3: ...ikin air condi tioner Carefully read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs After reading the manual fi...

Page 4: ...case of group control system one group of indoor units The unit is individually operated 1 WHAT TO DO BEFORE OPERA TION NOTE Contact your Daikin dealer in case of changing the combination or setting o...

Page 5: ...earth may cause electrical shock or fire A high surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an...

Page 6: ...DB 15 to 18 WB 10 to 30 DB 4 INSTALLATION SITE d Where there are considerable voltage fluctua tions such as a factory or plant e Vehicles and vessels f Where there is much spray of oil and vapor such...

Page 7: ...function If even one unit is equipped with the function the display will not appear 12 TIMER MODE START STOP BUTTON Refer to PROGRAM TIMER OPERATION hr hr C Refer to figure 1 on page 1 Operating proc...

Page 8: ...nside the air conditioner reaches a certain level At this time the remote controller displays Leave it as it stands and wait for a while When the warm air stays under the ceiling and your feet are col...

Page 9: ...objects near the air inlet and the air outlet of the unit It may cause deterioration in the effect or stop in the operation Turn off the main power supply switch when it is not used for long periods o...

Page 10: ...some watts of electricity is being used even if the sys tem is not operating Turn off the main power supply switch for saving energy The display on the remote controller will vanish when the main pow...

Page 11: ...unit blows out V THE UNITS GIVE OFF ODORS The unit absorbs the smell of rooms furniture cigarettes etc and then emits them VI THE LIQUID CRYSTAL OF THE REMOTE CON TROLLER SHOW It happens immediately a...

Page 12: ...of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle and make it well ventilated If the air filter is clogged Ask a qualified service person to clean the air filters Refer...

Page 13: ...3P156215 7K EM06A004A 0607 FS...

Reviews: