background image

7 Maintenance and service

User reference guide

7

FBA35~1FBA35~71A2VEB9
Split system air conditioners
4P543324-2 – 2018.08

7.3

To handle the drain pipe plug

NOTICE

▪ Do NOT remove the drain pipe plug. Water might leak

out.

▪ Use  the  drain  outlet  only  to  discharge  the  water  if  the

drain pump is not used or before maintenance.

▪ Insert  and  remove  the  drain  plug  gently.  Excessive

force may deform the drain socket of the drain pan.

1

Pull out the plug.

▪ Do NOT wiggle the plug up and down.

a

2

Push in the plug.

▪ Set the plug and push it in using a Phillips screwdriver.

a

b

a

Drain plug

b

Phillips screwdriver

7.4

Cleaning the air filter, suction
grille, air outlet and outside panels

7.4.1

To clean the air outlet and outside panels

WARNING

Do  NOT  let  the  indoor  unit  get  wet. 

Possible

consequence: 

Electric shock or fire.

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  50°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do  NOT  scrub  firmly  when  washing  the  blade  with

water. 

Possible  consequence: 

The  surface  sealing

peels off.

Clean with a soft cloth. If it is difficult to remove stains, use water or
neutral detergent.

7.4.2

To clean the air filter

When to clean the air filter

:

▪ Rule  of  thumb:  Clean  every  6  months.  If  the  air  in  the  room  is

extremely contaminated, increase the cleaning frequency.

▪ Depending  on  the  settings,  the  user  interface  can  display  the

TIME  TO  CLEAN  AIR  FILTER 

notification.  Clean  the  air  filter

when the notification is displayed.

▪ If  the  dirt  becomes  impossible  to  clean,  change  the  air  filter

(= optional equipment).

How to clean the air filter

:

1

Remove  the  air  filters  by  pulling  their  cloth  upward  (in  case  of
rear suction) or backward (in case of bottom suction).

rear suction

bottom suction

2

Clean the air filter. Use a vacuum cleaner or wash with water. If
the air filter is very dirty, use a soft brush and neutral detergent.

3

Dry the air filter in the shadow.

4

Reattach the air filter. Align the 2 hanger brackets and push the
2 clips in their place and pull the cloth if necessary.

rear suction

bottom suction

5

Confirm that 4 hangers are fixed.

6

In case of bottom suction, close the air inlet grille.

7

Turn ON the power.

8

Press the 

FILTER SIGN RESET

 button.

Result: 

The 

TIME  TO  CLEAN  AIR  FILTER

  notification  disappears

from the user interface.

7.5

Maintenance before a long stop
period

E.g., at the end of the season.

▪ Let the indoor units run in fan only operation for about half a day in

order to dry the interior of the units.

▪ Turn  off  the  power.  The  user  interface  display  disappears.  When

the  main  power  is  turned  on,  the  air  conditioner  will  use  some
power, even if it is not operating.

▪ Clean air filters and casings of indoor units. Contact your installer

or  maintenance  person  to  clean  air  filters  and  casings  of  the
indoor  unit.  Maintenance  tips  and  procedures  for  cleaning  are
provided in the installation/operation manuals of dedicated indoor
units.  Make  sure  to  install  cleaned  air  filters  back  in  the  same
position.

Summary of Contents for FBA35A2VEB9

Page 1: ...e Split system air conditioners English User reference guide Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB FBA35A2VEB9 FBA50A2VEB9 FBA60...

Page 2: ...he installation of the system and all activities described in the installation manual and the installer reference guide MUST be performed by an authorised installer 1 1 1 Meaning of warnings and symbo...

Page 3: ...door unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals product...

Page 4: ...l per speed setting if applicable LWA E dB Contact details DAIKIN INDUSTRIES CZECH REPUBLIC s r o U Nov Hospody 1 1155 301 00 Plze Skvr any Czech Republic A B C D E FBA125A 7 83 4 27 13 50 0 35 62 FBA...

Page 5: ...interface Cooling Heating 17 32 C 16 31 C 5 2 Operation procedure Turn on the power at least 6 hours before operating the unit in order to ensure smoother operation As soon as the power is turned on...

Page 6: ...he system expressed as tonnes CO2 equivalent is used to determine the maintenance intervals Follow the applicable legislation Formula to calculate the greenhouse gas emissions GWP value of the refrige...

Page 7: ...the settings the user interface can display the TIME TO CLEAN AIR FILTER notification Clean the air filter when the notification is displayed If the dirt becomes impossible to clean change the air fi...

Page 8: ...any obstacles and make sure the air can flow freely Check if the air filter is clogged Contact your dealer to clean the air filter Malfunction Measure The system operates but cooling or heating is ins...

Page 9: ...8 1 5 Symptom The operation stopped suddenly Operation lamp is on The air conditioner may stop for system protection due to large voltage fluctuation It automatically resumes operation after about 3 m...

Page 10: ......

Page 11: ......

Page 12: ...4P543324 2 2018 08 Copyright 2018 Daikin...

Reviews: