background image

6 Energy saving and optimum operation

User reference guide

5

FBA35~1FBA35~71A2VEB9
Split system air conditioners
4P543324-2 – 2018.08

Outdoor units

Cooling

Heating

RQ71~125

–5~46°C DB

–9~21°C DB

–10~15°C WB

18~37°C DB

12~28°C WB

10~27°C DB

RXS35~60

–10~46°C DB

–15~24°C DB

–16~18°C WB

18~32°C DB

10~30°C DB

3MXS40~68

4MXS68~80

5MXS90

–10~46°C DB

–15~24°C DB

–16~18°C WB

18~32°C DB

10~30°C DB

RZQG71~140

–15~50°C DB

–19~21°C DB

–20~15.5°C WB

18~37°C DB

12~28°C WB

10~27°C DB

RZQSG71~140

–15~46°C DB

–14~21°C DB

–15~15.5°C WB

20~37°C DB

14~28°C WB

10~27°C DB

RZQ200~250

–5~46°C DB

–14~21°C DB

–15~15°C WB

20~37°C DB

14~28°C WB

10~27°C DB

Indoor humidity

≤80%

(a)

For combination with R32 outdoor unit, refer to the following table:

Outdoor units

Cooling

Heating

RXM35~60

–10~46°C DB

–15~24°C DB

–16~18°C WB

18~32°C DB

10~30°C DB

3MXM40~68

4MXM68~80

5MXM90

–10~46°C DB

–15~24°C DB

–16~18°C WB

18~32°C DB

10~30°C DB

RZAG35~60

–20~52°C DB

–20~24°C DB

–21~18°C WB

18~32°C DB

10~30°C DB

RZAG71~140

–20~52°C DB

–19.5~21°C DB

–20~15.5°C WB

18~37°C DB

12~28°C WB

10~27°C DB

RZASG71~140

–15~46°C DB

–14~21°C DB

–15~15.5°C WB

20~37°C DB

14~28°C WB

10~27°C DB

AZAS71~140

–15~46°C DB

–14~21°C DB

–15~15.5°C WB

20~37°C DB

14~28°C WB

10~27°C DB

Indoor humidity

≤80%

(a)

Symbol

Explanation

Outdoor temperature

Indoor temperature

(a)

To avoid condensation and water dripping out of the unit. If
the temperature or the humidity is beyond these conditions,
safety devices may be put in action and the air conditioner
may not operate.

Setting temperature range of the user interface:

Cooling

Heating

17~32°C

16~31°C

5.2

Operation procedure

▪ Turn  on  the  power  at  least  6  hours  before  operating  the  unit  in

order  to  ensure  smoother  operation.  As  soon  as  the  power  is
turned on, the user interface display appears.

▪ If  there  was  a  power  failure  during  operation,  the  system

automatically  restarts  immediately  after  the  power  supply  is
recovered.

▪ The setting temperature range of the user interface is described in

chapter "Operation range".

▪ If  you  select  a  function  which  is  not  available,  the  message

 appears on the user interface.

▪ The  operation  procedure  depends  on  the  model  (heat  pump  or

cooling only). Contact your dealer to confirm which model you are
using.

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

6

Energy saving and optimum
operation

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

WARNING

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

CAUTION

Do  NOT  operate  the  system  when  using  a  room
fumigation-type  insecticide.  Chemicals  could  collect  in  the
unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays. Doing so may result in
a fire.

Observe  the  following  precautions  to  ensure  the  system  operates
properly.

Summary of Contents for FBA35A2VEB9

Page 1: ...e Split system air conditioners English User reference guide Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB FBA35A2VEB9 FBA50A2VEB9 FBA60...

Page 2: ...he installation of the system and all activities described in the installation manual and the installer reference guide MUST be performed by an authorised installer 1 1 1 Meaning of warnings and symbo...

Page 3: ...door unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals product...

Page 4: ...l per speed setting if applicable LWA E dB Contact details DAIKIN INDUSTRIES CZECH REPUBLIC s r o U Nov Hospody 1 1155 301 00 Plze Skvr any Czech Republic A B C D E FBA125A 7 83 4 27 13 50 0 35 62 FBA...

Page 5: ...interface Cooling Heating 17 32 C 16 31 C 5 2 Operation procedure Turn on the power at least 6 hours before operating the unit in order to ensure smoother operation As soon as the power is turned on...

Page 6: ...he system expressed as tonnes CO2 equivalent is used to determine the maintenance intervals Follow the applicable legislation Formula to calculate the greenhouse gas emissions GWP value of the refrige...

Page 7: ...the settings the user interface can display the TIME TO CLEAN AIR FILTER notification Clean the air filter when the notification is displayed If the dirt becomes impossible to clean change the air fi...

Page 8: ...any obstacles and make sure the air can flow freely Check if the air filter is clogged Contact your dealer to clean the air filter Malfunction Measure The system operates but cooling or heating is ins...

Page 9: ...8 1 5 Symptom The operation stopped suddenly Operation lamp is on The air conditioner may stop for system protection due to large voltage fluctuation It automatically resumes operation after about 3 m...

Page 10: ......

Page 11: ......

Page 12: ...4P543324 2 2018 08 Copyright 2018 Daikin...

Reviews: