Neither place a flammable spray bottle near 
the air conditioner nor perform spraying.

Doing so may result in a fire.

To clean the air conditioner, stop operation, 
and unplug the power cord from the outlet.

Otherwise, an electric shock and injury may result.

Do not operate the air conditioner with a wet 
hand.

An electric shock may result.

Do not place items that might be damaged by 
water under the indoor unit.

Water may condensate and drip if the humidity 
reaches 80% or if the drain exit gets clogged.

Do not place a burner or heater at a place 
directly exposed to the wind from the air con-
ditioner.

Incomplete combustion of the burner or heater 
may result.

Do not allow a child to mount on the outdoor 
unit or avoid placing any object on it.

Falling or tumbling may result in injury.

Do not expose animals and plants directly to 
the wind.

Adverse influence to animals and plants may 
result.

Do not wash the air conditioner with water.

Electric shock or fire may result.

Do not install the air conditioner at any place 
where flammable gas may leak out.

If the gas leaks out and stays around the air con-
ditioner, a fire may break out.

Execute complete drain piping for perfect 
drainage.

Incomplete piping may result in a water leakage.

The appliance is not intended for use by young 
children or infirm persons without supervision.
Young children should be supervised to 
ensure that they do not play with the appliance.
Consult with installation contractor for 
cleaning the inside of the air conditioner.

Wrong cleaning may make the plastics parts 
broken or cause failure of water leakage or elec-
tric shock.

Do not touch the air inlet or aluminium fin of 
the air conditioner.

Otherwise, injury may be caused.

Do not place objects in direct proximity of the 
outdoor unit and do not let leaves and other 
debris accumulate around the unit.

Leaves are a hotbed for small animals which can 
enter the unit. Once in the unit, such animals can 
cause malfunctions, smoke or fire when making 
contact with electrical parts.

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.

COOLING

HEATING

For Australia model Only

COOLING

HEATING

D

 

B: Dry bulb temperature

WB: Wet bulb temperature

The setting temperature range of the remote con-
troller is 16°C to 32°C.

3. OPERATION RANGE

OUTDOOR 
UNIT

INDOOR

OUTDOOR 
TEMPERATURE 

TEMPERA-
TURE

HUMIDITY

RZQ71·140

DB

18 to 37

80% or 
below

DB

–15 to 50

WB 12 to 28

RQ71

DB

18 to 37

80% or 
below

DB

– 5 to 46

WB 12 to 28

RR71

DB

18 to 37

80% or 
below

DB

–15 to 46

WB 12 to 28

OUTDOOR UNIT

INDOOR 
TEMPERATURE

OUTDOOR 
TEMPERATURE

RZQ71·140

DB

10 to 27

DB

–19.5 to 21

WB

–20 to 15.5

RQ71

DB

10 to 27

DB

– 9 to 21

WB

–10 to 15

OUTDOOR 
UNIT

INDOOR

OUTDOOR 
TEMPERATURE 

TEMPERA-
TURE

HUMIDITY

RZQ71

DB

20 to 37

80% or 
below

DB

–5 to 46

WB 14 to 28

OUTDOOR UNIT

INDOOR 
TEMPERATURE

OUTDOOR 
TEMPERATURE

RZQ71

DB

10 to 27

DB

–14 to 21

WB

–15 to 15.5

Summary of Contents for FAQ71BVV1B

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Wall mounted type FAQ71BUV1B FAQ71BVV1B English Deutsch Fran ais Espa ol Italiano Nederlands Portugues...

Page 2: ...1 b d f k e i h a j d f g e c...

Page 3: ...de aver a Este manual describe s lo la unidad interior Utilice conjuntamente con el manual de instrucciones de la unidad exterior Despu s de leer el manual cons rvelo para consultas futuras Funcionam...

Page 4: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 5: ...thout romote controller When used as simultaneous operation system PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside in...

Page 6: ...nditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the limiting concentration even when it leaks If the...

Page 7: ...y do not play with the appliance Consult with installation contractor for cleaning the inside of the air conditioner Wrong cleaning may make the plastics parts broken or cause failure of water leakage...

Page 8: ...g air conditioning operation chances are that dust and dirt are clogged in the pipe This may result in a water leakage from the indoor unit Under such circumstances stop the operation of the air condi...

Page 9: ...HT DIRECTION Hold the tabs on edge louvers horizontal fan direc tion adjustment flaps down slightly and adjust left and right to match the room conditions or your pref erence Stop the horizontal flaps...

Page 10: ...the tab in the center of the air filter slightly then pull out in a downward direction 7 MAINTENANCE FOR SERVICE PERSONNEL 3 Clean the air filter Use vacuum cleaner A or wash the air filter with water...

Page 11: ...operation manual that came with the remote controller Cut off the power supply When the main power switch is turned on some watts of electricity is being used even if the sys tem is not operating Turn...

Page 12: ...immediately after the stop of operation or which is heard at the start or immediately after the stop of DEFROST OPERATION This is the noise of refrigerant caused by flow stop and flow change A contin...

Page 13: ...ilter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE OPERATION lamp INSPECTION display MALFUNCTION CODE INDOOR UNIT No in which a malfunction occurs UNIT No C...

Page 14: ...3PN07753 5 EM03A090C 0608 FS...

Reviews: