background image

6

English

energy. When reoperating, turn on the main power 
supply switch 6hours before operation for smooth 
running (Refer to MAINTENANCE).

When the display shows “

”, ask a qualified 

service person to clean the filters (Refer to MAIN-
TENANCE).

ONLY A QUALIFIED SERVICE PERSON IS 
ALLOWED TO PERFORM MAINTENANCE

IMPORTANT!

• BEFORE OBTAINING ACCESS TO TERMINAL 

DEVICES, ALL POWER SUPPLY CIRCUITS 
MUST BE INTERRUPTED

To clean the air conditioner, be sure to stop oper-
ation, and turn the power switch off. Otherwise, an 
electric shock and injury may result.

Do not wash the air conditioner with water
Doing so may result in an electric shock.

Be careful with a scaffold or staging
Caution must be exercised because of work at a 
high place.

HOW TO CLEAN THE AIR FILTER

Clean the air filter when the display shows “

”. 

Increase the frequency of cleaning if the unit is 
installed in a room where the air is extremely 
contaminated.
(As a yardstick for regulating yourself, consider 
cleaning the filter once every two weeks.)

1. Open the front panel.

Place your fingers on the panel protrusions on 
the left and right sides of the main unit and open 
until the panel stops.

2. Pullout the air filter.

Push up the tab in the center of the air filter 
slightly then pull out in a downward direction.

7. MAINTENANCE

(FOR SERVICE PERSONNEL)

3. Clean the air filter.

Use vacuum cleaner 

A)

 or wash the air filter with 

water

 B).

A)

Using a vacuum cleaner

B)

Washing with water
When the air filter is very 
dirty, use soft brush and 
neutral detergent.

Remove water and dry in 
the shade.

NOTE

Do not wash the air conditioner with hot water of 
more than 50°C, as doing so may result in discol-
oration and/or deformation.

Do not expose it to fire, as doing so may result in 
burning.

4. Attach the air filter.

Once cleaning is done be sure to replace the air 
filter as it was.

5. After turning on the power, press AIR FILTER 

CLEANING TIME ICON RESET BUTTON.

The display “ 

” vanishes.

HOW TO CLEAN THE AIR OUTLET AND 
EXTERIOR

Clean with soft cloth.

When it is difficult to remove stains, use water or 
neutral detergent.

NOTE

Do not use gasoline, benzene, thinner, polishing 
powder, liquid insecticide. It may cause discolor-
ing or warping.

Do not use water or air of 50°C or higher for clean-
ing air filters.

HOW TO CLEAN THE FRONT PANEL

You can remove the front panel to clean it.

NOTES

Hold the front panel firmly so that it does not fall.

Do not use water over 50 °C, benzine, gasoline, 
thinner, or other volatile substances, polishing 
powder, or hard scrub brushes to clean the panel.

Make sure the front panel is solidly in place.

Summary of Contents for FAQ71BVV1B

Page 1: ...SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Wall mounted type FAQ71BUV1B FAQ71BVV1B English Deutsch Fran ais Espa ol Italiano Nederlands Portugues...

Page 2: ...1 b d f k e i h a j d f g e c...

Page 3: ...de aver a Este manual describe s lo la unidad interior Utilice conjuntamente con el manual de instrucciones de la unidad exterior Despu s de leer el manual cons rvelo para consultas futuras Funcionam...

Page 4: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 5: ...thout romote controller When used as simultaneous operation system PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside in...

Page 6: ...nditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the limiting concentration even when it leaks If the...

Page 7: ...y do not play with the appliance Consult with installation contractor for cleaning the inside of the air conditioner Wrong cleaning may make the plastics parts broken or cause failure of water leakage...

Page 8: ...g air conditioning operation chances are that dust and dirt are clogged in the pipe This may result in a water leakage from the indoor unit Under such circumstances stop the operation of the air condi...

Page 9: ...HT DIRECTION Hold the tabs on edge louvers horizontal fan direc tion adjustment flaps down slightly and adjust left and right to match the room conditions or your pref erence Stop the horizontal flaps...

Page 10: ...the tab in the center of the air filter slightly then pull out in a downward direction 7 MAINTENANCE FOR SERVICE PERSONNEL 3 Clean the air filter Use vacuum cleaner A or wash the air filter with water...

Page 11: ...operation manual that came with the remote controller Cut off the power supply When the main power switch is turned on some watts of electricity is being used even if the sys tem is not operating Turn...

Page 12: ...immediately after the stop of operation or which is heard at the start or immediately after the stop of DEFROST OPERATION This is the noise of refrigerant caused by flow stop and flow change A contin...

Page 13: ...ilter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE OPERATION lamp INSPECTION display MALFUNCTION CODE INDOOR UNIT No in which a malfunction occurs UNIT No C...

Page 14: ...3PN07753 5 EM03A090C 0608 FS...

Reviews: