IM 871-3 

Page 11 of 12

24. Reattach ExtendAire primary section to the unit. See step 

7 and refer to 

Figure 10 on page 5

 for installation  

instructions. Re-attach the 3' extension to the primary 
discharge section and through the adjoining room cutout.

25. Secure the boost fan power cord within the primary 

discharge section with the two remaining zip-ties.

NOTICE

  The boost fan power cord must run over the top of the primary 

discharge section mounting brackets, see 

Figure 22

 detail.

26. Reinstall unit chassis into wall sleeve, if removed. 

27. Route the boost fan power cord plug through the discharge 

air opening in the cabinet/wall sleeve. The plug should exit 
along the side of the control box where it will plug into the 
boost fan motor wire harness (See detail in 

Figure 22 and 

Figure 23

).

28. Connect the two Molex connectors inside the unit to 

provide control to the boost fan (

Figure 23

).

29. Feed the LUI communication cable through the control 

door opening in the primary discharge section and plug into 
the COM terminal on the premium control board. Also, 
re-connect the remaining connectors onto the appropriate 
terminals at the top of the premium control board.

Figure 22: Boost Fan assembly details

Boost fan positioned 
midway inside 
extension section

Boost fan power cord 
secured with two (2) zip 
ties in primary section

Trim piece

Removed right end 
and left end grilles

Boost fan power cord plug

Primary discharge air section

Detail

Zip-tie location (1) in 
3' extension section

Figure 23: Make plug connection of boost fan to fan motor

Boost Fan power cord 
connector into Fan 
Motor wire harness 
connector

30. Snap LUI touchpad control bezel into the opening of the 

control access door.

31. Return the front panel to the cabinet/wall sleeve and restore 

power to the unit.

Note:  Boost fan will run whenever indoor fan is operational, 

regardless of speed of indoor fan.

Summary of Contents for ExtendAire IM 871-3

Page 1: ...ty in Each Package Part Number Primary Discharge Section1 1 910106134 Shelf Discharge Assembly Primary Discharge Section1 1 Shelf Discharge Assembly 3 Foot Extension Section 1 Shelf Discharge Assembly...

Page 2: ...llips head screw on top of the mounting bracket to secure the discharge section to the cabinet wall sleeve Note Be sure the primary discharge section is positioned evenly end to end with the cabinet w...

Page 3: ...pad up and through the primary discharge section control door opening Check the communication cable for proper connection to the Touchpad and the control board Figure 5 Position and tighten screws on...

Page 4: ...he underside of the touchpad control opening Unplug the touchpad com munication cable from the control board 3 Remove the two 2 screws located at each end of the cabinet wrap securing it to the wall s...

Page 5: ...rd will pass through the primary discharge section and over the mounting brackets and not underneath Note Be sure the primary discharge section is positioned evenly end to end with the cabinet wall sl...

Page 6: ...wall sleeve Refer to the specific configuration for installation details Note Upon completion of the selected configuration refer to steps 2 3 and 4 on page 7 Configuration 1 Shelf Discharge Assembly...

Page 7: ...lles to the right and inactive grilles to the left when facing unit 3 Cover joints with trim pieces 4 Make sure there is at least 35 sq in free area return air opening from adjoining room Undercut doo...

Page 8: ...d Figure 8 on page 4 To remove the chassis remove screws at locations shown in Note After completing steps 2a or 2b and 3a or 3b continue the Boost Fan installation as follows Figure 15 Remove the two...

Page 9: ...igure 19 and insert the end of the orange wire detached from the plug connector into the kit provided butt connector and crimp In the opposite end of the butt connector insert the orange wire attached...

Page 10: ...0 Remove the LUI touchpad from the unit control door opening 21 If primary ExtendAire discharge section has a reach through style door remove the discharge grille section by carefully straightening ta...

Page 11: ...the unit to provide control to the boost fan Figure 23 29 Feed the LUI communication cable through the control door opening in the primary discharge section and plug into the COM terminal on the premi...

Page 12: ...d pursuant to its standard terms and conditions of sale including Limited Product Warranty Consult your local Daikin Representative for warranty details Refer to Form 933 430285Y To find your local Da...

Reviews: