5
|
About the units and options
Installer reference guide
28
ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05
5 About the units and options
INFORMATION
This unit is a heating only model. Therefore, all references to cooling in this
document are NOT applicable.
In this chapter
5.1 Identification
5.1.1 Identification label: Outdoor unit
Location
Model identification
Example:
ER L A 16 DA V3 7
Code
Explanation
ER
European refrigerant split outdoor pair heat pump
L
Low water temperature – ambient zone 2 (see operation
range)
A
Refrigerant R32
16
Capacity class
DA
Model series
V3
Power supply:
V3=1N~, 230 V AC, 50 Hz
W1=3N~, 400 V AC, 50 Hz
7
Model series
Summary of Contents for ERLA-DV17