background image

Table of contents

Installation manual

4

ERGA04~08DAV3

Daikin Altherma – Low temperature split

4P489913-1B – 2017.10

Table of contents

1 About the documentation

4

1.1

About this document..................................................................

4

2 About the box

4

2.1

Outdoor unit...............................................................................

4

2.1.1

To handle the outdoor unit ..........................................

4

2.1.2

To remove the accessories from the outdoor unit.......

5

3 Preparation

5

3.1

Preparing the installation site ....................................................

5

3.1.1

Installation site requirements of the outdoor unit ........

5

3.1.2

Additional installation site requirements of the
outdoor unit in cold climates .......................................

5

4 Installation

6

4.1

Opening the units ......................................................................

6

4.1.1

To open the outdoor unit.............................................

6

4.2

Mounting the outdoor unit..........................................................

6

4.2.1

To provide the installation structure ............................

6

4.2.2

To install the outdoor unit............................................

7

4.2.3

To provide drainage ....................................................

7

4.2.4

To prevent the outdoor unit from falling over ..............

8

4.3

Connecting the refrigerant piping ..............................................

8

4.3.1

To connect the refrigerant piping to the outdoor unit ..

8

4.4

Checking the refrigerant piping .................................................

8

4.4.1

To check for leaks.......................................................

8

4.4.2

To perform vacuum drying ..........................................

8

4.5

Charging refrigerant ..................................................................

9

4.5.1

To determine the additional refrigerant amount ..........

9

4.5.2

To charge additional refrigerant ..................................

9

4.5.3

To fix the fluorinated greenhouse gases label ............

9

4.6

Connecting the electrical wiring.................................................

9

4.6.1

About electrical compliance ........................................

9

4.6.2

Specifications of standard wiring components............

9

4.6.3

To connect the electrical wiring on the outdoor unit....

9

4.7

Finishing the outdoor unit installation ........................................

10

4.7.1

To finish the outdoor unit installation .......................... 10

5 Starting up the outdoor unit

10

6 Technical data

10

6.1

Piping diagram: Outdoor unit.....................................................

11

6.2

Wiring diagram: Outdoor unit ....................................................

12

1

About the documentation

1.1

About this document

Target audience

Authorised installers

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Outdoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Addendum book for optional equipment:

▪ Additional info about how to install optional equipment

▪ Format:  Paper  (in  the  box  of  the  indoor  unit)  +  Digital  files  on

http://www.daikineurope.com/support-and-manuals/product-
information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

extranet (authentication required).

2

About the box

2.1

Outdoor unit

2.1.1

To handle the outdoor unit

CAUTION

To  avoid  injury,  do  NOT  touch  the  air  inlet  or  aluminium
fins of the unit.

1

Handle the unit using the sling to the left and the handle to the
right. Pull up both sides of the sling at the same time to prevent
disconnection of the sling from the unit.

2

1

1

Summary of Contents for ERGA04DAV3

Page 1: ...Installation manual Daikin Altherma Low temperature split English Installation manual Daikin Altherma Low temperature split ERGA04DAV3 ERGA06DAV3 A ERGA08DAV3 A...

Page 2: ...owieniami Dyrektyw n urma prevederilor 19 20 21 22 23 24 25 ob upo tevanju dolo b vastavalt n uetele laikantis nuostat pateikiam iev rojot pras bas kas noteiktas odr iavaj c ustanovenia bunun ko ullar...

Page 3: ...taava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplota TS...

Page 4: ...m Outdoor unit 11 6 2 Wiring diagram Outdoor unit 12 1 About the documentation 1 1 About this document Target audience Authorised installers Documentation set This document is part of a documentation...

Page 5: ...stored in a room without continuously operating ignition sources example open flames an operating gas appliance or an operating electric heater 3 1 1 Installation site requirements of the outdoor unit...

Page 6: ...outdoor unit on page 9 4 2 Mounting the outdoor unit 4 2 1 To provide the installation structure This topic shows different installation structures For all use 4 sets of M8 or M10 anchor bolts nuts a...

Page 7: ...o the right 2 Remove the sling by pulling 1 side of the sling 3 Fix the unit 2 3 2 1 a a a Air outlet NOTICE Properly align the unit Make sure the backside of the unit does NOT protrude 3 Remove the p...

Page 8: ...indoor unit to the gas stop valve of the outdoor unit NOTICE It is recommended that the refrigerant piping between indoor and outdoor unit is installed in a ducting or the refrigerant piping is wrapp...

Page 9: ...1000 kg kg GWP XXX RXXX a f c d e a If a multilingual fluorinated greenhouse gases label is delivered with the unit see accessories peel off the applicable language and stick it on top of a b Factory...

Page 10: ...tie 1 1 5 Connect an earth leakage circuit breaker and fuse to the power supply line 4 7 Finishing the outdoor unit installation 4 7 1 To finish the outdoor unit installation 1 Insulate and fix the r...

Page 11: ...Y1S 4 0 CuT M1F b a c d e f g h i j k k g g a Field piping liquid 6 4 mm flare connection b Field piping gas 15 9 mm flare connection c Stop valve liquid d Stop valve with service port gas e Filter f...

Page 12: ...en YLW yellow 3 Legend AL Connector C Capacitor DB Rectifier bridge DC Connector DP Connector E Connector F1U Fuse T 6 3 A 250 V FU1 FU2 Fuse T 3 15 A 250 V FU3 Fuse T 30 A 250 V H Connector IPM Intel...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...4P489913 1B 2017 10 Copyright 2017 Daikin...