6 Technical data

Installation manual

11

ERGA04~08DAV3
Daikin Altherma – Low temperature split
4P489913-1B – 2017.10

6.1

Piping diagram: Outdoor unit

R2T

7.0 CuT
7.0 CuT

7.0 CuT
7.0 CuT

7.0 CuT
7.0 CuT

12.7 CuT

12.7 CuT

12.7 CuT

6.4 CuT

6.4 CuT

6.4 CuT

6.4 CuT

4.0 CuT

4.0 CuT

9.5  CuT

15.9 CuT

3D110394

9.5 CuT

12.7 CuT

15.9 CuT

6.4 CuT

S1PH

Y1E

R1T

R3T

M1C

Y1S

4.0 CuT

M1F

b

a

c

d

e

f

g

h

i

j

k

k

g

g

a

Field piping (liquid: Ø6.4 mm flare connection)

b

Field piping (gas: Ø15.9 mm flare connection)

c

Stop valve (liquid)

d

Stop valve with service port (gas)

e

Filter

f

Muffler with filter

g

Capillary tube

h

Heat exchanger

i

Accumulator

j

Compressor accumulator

k

Muffler

M1C

Compressor

M1F

Fan

R1T

Thermistor (outdoor air)

R2T

Thermistor (heat exchanger)

R3T

Thermistor (compressor discharge)

S1PH

High pressure switch (automatic reset)

Y1E

Electronic expansion valve

Y1S

Solenoid valve (4‑way valve)(ON: cooling)
Heating
Cooling

Summary of Contents for ERGA04DAV3

Page 1: ...Installation manual Daikin Altherma Low temperature split English Installation manual Daikin Altherma Low temperature split ERGA04DAV3 ERGA06DAV3 A ERGA08DAV3 A...

Page 2: ...owieniami Dyrektyw n urma prevederilor 19 20 21 22 23 24 25 ob upo tevanju dolo b vastavalt n uetele laikantis nuostat pateikiam iev rojot pras bas kas noteiktas odr iavaj c ustanovenia bunun ko ullar...

Page 3: ...taava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplota TS...

Page 4: ...m Outdoor unit 11 6 2 Wiring diagram Outdoor unit 12 1 About the documentation 1 1 About this document Target audience Authorised installers Documentation set This document is part of a documentation...

Page 5: ...stored in a room without continuously operating ignition sources example open flames an operating gas appliance or an operating electric heater 3 1 1 Installation site requirements of the outdoor unit...

Page 6: ...outdoor unit on page 9 4 2 Mounting the outdoor unit 4 2 1 To provide the installation structure This topic shows different installation structures For all use 4 sets of M8 or M10 anchor bolts nuts a...

Page 7: ...o the right 2 Remove the sling by pulling 1 side of the sling 3 Fix the unit 2 3 2 1 a a a Air outlet NOTICE Properly align the unit Make sure the backside of the unit does NOT protrude 3 Remove the p...

Page 8: ...indoor unit to the gas stop valve of the outdoor unit NOTICE It is recommended that the refrigerant piping between indoor and outdoor unit is installed in a ducting or the refrigerant piping is wrapp...

Page 9: ...1000 kg kg GWP XXX RXXX a f c d e a If a multilingual fluorinated greenhouse gases label is delivered with the unit see accessories peel off the applicable language and stick it on top of a b Factory...

Page 10: ...tie 1 1 5 Connect an earth leakage circuit breaker and fuse to the power supply line 4 7 Finishing the outdoor unit installation 4 7 1 To finish the outdoor unit installation 1 Insulate and fix the r...

Page 11: ...Y1S 4 0 CuT M1F b a c d e f g h i j k k g g a Field piping liquid 6 4 mm flare connection b Field piping gas 15 9 mm flare connection c Stop valve liquid d Stop valve with service port gas e Filter f...

Page 12: ...en YLW yellow 3 Legend AL Connector C Capacitor DB Rectifier bridge DC Connector DP Connector E Connector F1U Fuse T 6 3 A 250 V FU1 FU2 Fuse T 3 15 A 250 V FU3 Fuse T 30 A 250 V H Connector IPM Intel...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...4P489913 1B 2017 10 Copyright 2017 Daikin...

Reviews: