background image

Installation manual

Daikin Altherma – Low temperature split

English

Installation manual

Daikin Altherma – Low temperature split

ERGA04DAV3
ERGA06DAV3(A)
ERGA08DAV3(A)

Summary of Contents for ERGA04DAV3

Page 1: ...Installation manual Daikin Altherma Low temperature split English Installation manual Daikin Altherma Low temperature split ERGA04DAV3 ERGA06DAV3 A ERGA08DAV3 A...

Page 2: ...owieniami Dyrektyw n urma prevederilor 19 20 21 22 23 24 25 ob upo tevanju dolo b vastavalt n uetele laikantis nuostat pateikiam iev rojot pras bas kas noteiktas odr iavaj c ustanovenia bunun ko ullar...

Page 3: ...taava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplota TS...

Page 4: ...m Outdoor unit 11 6 2 Wiring diagram Outdoor unit 12 1 About the documentation 1 1 About this document Target audience Authorised installers Documentation set This document is part of a documentation...

Page 5: ...stored in a room without continuously operating ignition sources example open flames an operating gas appliance or an operating electric heater 3 1 1 Installation site requirements of the outdoor unit...

Page 6: ...outdoor unit on page 9 4 2 Mounting the outdoor unit 4 2 1 To provide the installation structure This topic shows different installation structures For all use 4 sets of M8 or M10 anchor bolts nuts a...

Page 7: ...o the right 2 Remove the sling by pulling 1 side of the sling 3 Fix the unit 2 3 2 1 a a a Air outlet NOTICE Properly align the unit Make sure the backside of the unit does NOT protrude 3 Remove the p...

Page 8: ...indoor unit to the gas stop valve of the outdoor unit NOTICE It is recommended that the refrigerant piping between indoor and outdoor unit is installed in a ducting or the refrigerant piping is wrapp...

Page 9: ...1000 kg kg GWP XXX RXXX a f c d e a If a multilingual fluorinated greenhouse gases label is delivered with the unit see accessories peel off the applicable language and stick it on top of a b Factory...

Page 10: ...tie 1 1 5 Connect an earth leakage circuit breaker and fuse to the power supply line 4 7 Finishing the outdoor unit installation 4 7 1 To finish the outdoor unit installation 1 Insulate and fix the r...

Page 11: ...Y1S 4 0 CuT M1F b a c d e f g h i j k k g g a Field piping liquid 6 4 mm flare connection b Field piping gas 15 9 mm flare connection c Stop valve liquid d Stop valve with service port gas e Filter f...

Page 12: ...en YLW yellow 3 Legend AL Connector C Capacitor DB Rectifier bridge DC Connector DP Connector E Connector F1U Fuse T 6 3 A 250 V FU1 FU2 Fuse T 3 15 A 250 V FU3 Fuse T 30 A 250 V H Connector IPM Intel...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...4P489913 1B 2017 10 Copyright 2017 Daikin...