background image

 

 

1

DAI

KIN

4

7

3

1

2

104,5

28

45,5

54

182

82

43

109,5

238

ER 3DA

ER 5DA

160

69,5

45

43

54

899

389

139

197

ER 10DA

160

69,5

45

43

54

643

389

139

197

205

69,5

38

43

54

590

403

132

82

5

5

5

5

6

6

6

6

ER 8DA

 

 

2

DAIK

IN

J

E

H

F

I

B

D

K

A

C

G

A

B

C

D

E

F

G

H

I

J

K

ER3DA

(mm)

922

640

375

30

796

294

371

39

966

996

15

ER5DA

(mm)

922

640

375

30

1179

294

371

39

966

996

15

ER8DA

(mm)

1390

1021

375

30

1254

294

371

39

1434

1464

15

ER10DA

(mm)

1390

1021

375

30

1560

294

371

39

1434

1464

15

 

 

3

DAIK

IN

F

D

A

B

E

C

A

B

C

D

E

F

ER3DA

(mm)

800

500

1075

300

800

1055

ER5DA

(mm)

800

500

1075

300

800

1055

ER8DA

(mm)

800

500

1170

300

800

1140

ER10DA

(mm)

800

500

1170

300

800

1140

 

4a 

 

4a

N2

7

9

3

2

4

1

6

5

8

 

4b 

 

4b

11

12

10

 

5a 

 

5a

R22

7

8

5

2

3

4

 

5b 

 

5b

R22

7

8

5

2

3

4

 

 

6

ER   3DAW1
ER   5DAW1
ER   8DAW1
ER 10DAW1

L1

L2

L3

L1

L2

L3

3N~ 50Hz 380/415V 

F2U

F3U

F4U

N

N

S3S

1

3

5

6

4

 

 

7

ER   3DAT1
ER   5DAT1
ER   8DAT1
ER 10DAT1

L1

L2

L3

L1

L2

L3

3~ 50Hz 220V

F2U

F3U

F4U

S3S

1

3

5

6

4

 

 

8

ER   3DAV1

L1

L2

L1

L2

1~ 50Hz 220V/240V

F2U

F3U

S3S

1

3

5

6

4

Summary of Contents for ER10DAT1

Page 1: ...INSTALLATION MANUAL ER3DAW1 ER3DAT1 ER3DAV1 ER5DAW1 ER5DAT1 ER8DAW1 ER8DAT1 ER10DAW1 ER10DAT1 Air cooled condensing units...

Page 2: ...1464 15 ER10DA mm 1390 1021 375 30 1560 294 371 39 1434 1464 15 3 3 DAIKIN F D A B E C A B C D E F ER3DA mm 800 500 1075 300 800 1055 ER5DA mm 800 500 1075 300 800 1055 ER8DA mm 800 500 1170 300 800...

Page 3: ...ons can be purchased to allow easier installation MAIN COMPONENTS refer to figure 1 ER3DA ER5DA ER8DA ER10DA Air cooled condensing units Installation manual IMPROPER INSTALLATION OR ATTACHMENT OF EQUI...

Page 4: ...standing supports Attach the unit to the supports using the bolts spring lock washers and nuts provided with the kit 4 Level the unit in both directions 5 Use four anchor bolts with M8 thread to fix t...

Page 5: ...rom the gauge manifold 20 Remove the blind cap from the gas line stop valve 11 and the liquid line stop valve 12 21 Loosen the gland packing retainers of the gas line stop valve 11 and the liquid line...

Page 6: ...licensed electrician and must comply with relevant European and national regulations The field wiring must be carried out in accordance with the wiring diagrams see figure 6 figure 7 and figure 8 and...

Page 7: ...it and the switch box of the air conditioning unit The cable must be of the type H05VV U5X1 5 and must be connected to terminals 1 3 4 5 and 6 of the condensing unit as shown on the wiring diagrams se...

Page 8: ...NOTES NOTES...

Page 9: ...eration of the air conditioning system is then controlled by the remote control Shut down by switching off the remote control and the circuit breaker of the power circuit WARNINGS Emergency shut down...

Page 10: ...NOTES...

Page 11: ...NOTES...

Page 12: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN00410 1C...