background image

Table of contents

Installation manual

2

FTXJ35MV1BS/W6

Split system air conditioners

3P482320-15Z – 2021.10

Table of contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 Specific installer safety instructions

2

3 About the box

3

3.1

Indoor unit .................................................................................

3

3.1.1

To remove the accessories from the indoor unit.........

3

4 About the unit

4

4.1

Operation range ........................................................................

4

4.2

About the wireless LAN .............................................................

4

4.2.1

Precautions when using the wireless LAN..................

4

4.2.2

Basic parameters ........................................................

4

5 Unit installation

4

5.1

Preparing the installation site ....................................................

4

5.1.1

Installation site requirements of the indoor unit ..........

4

5.2

Mounting the indoor unit............................................................

5

5.2.1

To install the mounting plate .......................................

5

5.2.2

To drill a wall hole .......................................................

5

5.2.3

To remove the pipe port cover ....................................

5

5.3

Connecting the drain piping.......................................................

6

5.3.1

To connect the piping on right side, right-back, or
right-bottom.................................................................

6

5.3.2

To connect the piping on left side, left-back, or left-
bottom .........................................................................

6

5.3.3

To check for water leaks .............................................

6

6 Piping installation

7

6.1

Preparing refrigerant piping .......................................................

7

6.1.1

Refrigerant piping requirements..................................

7

6.1.2

Refrigerant piping insulation .......................................

7

6.2

Connecting the refrigerant piping ..............................................

7

6.2.1

To connect the refrigerant piping to the indoor unit ....

7

7 Electrical installation

7

7.1

Specifications of standard wiring components ..........................

8

7.2

To connect the electrical wiring to the indoor unit .....................

8

7.3

To connect optional accessories (wired user interface, central
user interface, etc.)....................................................................

8

8 Finishing the indoor unit installation

8

8.1

To insulate the drain piping, refrigerant piping and
interconnection cable ................................................................

8

8.2

To pass the pipes through the wall hole....................................

9

8.3

To fix the unit on the mounting plate .........................................

9

9 Configuration

9

9.1

To set a different address..........................................................

9

10 Commissioning

10

10.1

Checklist before commissioning ................................................

10

10.2

To perform a test run .................................................................

10

10.2.1

To perform a test run using the user interface ............ 10

11 Disposal

10

12 Technical data

10

12.1

Wiring diagram ..........................................................................

10

12.1.1

Unified wiring diagram legend..................................... 11

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied materials follow the instructions from Daikin and, in
addition,  comply  with  applicable  legislation  and  are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

Specific installer safety
instructions

Always observe the following safety instructions and regulations.

Unit installation (see 

"5 Unit installation"

 [

4

 4])

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

Summary of Contents for Emura FTXJ-MW

Page 1: ...Installation manual Split system air conditioners English Installation manual Split system air conditioners FTXJ35MV1BW6 FTXJ35MV1BS6...

Page 2: ...al data 10 12 1 Wiring diagram 10 12 1 1 Unified wiring diagram legend 11 1 About the documentation 1 1 About this document INFORMATION Make sure that the user has the printed documentation and ask hi...

Page 3: ...N phase equipment might break down Establish proper earthing Do NOT earth the unit to a utility pipe surge absorber or telephone earth Incomplete earthing may cause electrical shock Install the requi...

Page 4: ...he latest version of this manual visit app daikineurope com INFORMATION Daikin Industries Czech Republic s r o declares that the radio equipment type inside of this unit is in compliance with Directiv...

Page 5: ...4 25L screws field supply INFORMATION The removed pipe port cover can be kept in the mounting plate pocket mm 998 357 135 142 348 160 151 65 6 5 49 100 200 124 303 49 50 203 234 67 a f b c d e h g a R...

Page 6: ...the piping on left side left back or left bottom INFORMATION The factory default is right side piping For left side piping remove the piping from the right side and install it on the left side 1 Remov...

Page 7: ...temperature is higher than 30 C and the humidity is higher than RH 80 the thickness of the insulation materials should be at least 20 mm to prevent condensation on the surface of the insulation 6 2 Co...

Page 8: ...t least 50 mm WARNING Provide adequate measures to prevent that the unit can be used as a shelter by small animals Small animals that make contact with electrical parts can cause malfunctions smoke or...

Page 9: ...bottom frame of the unit with both hands to set it on the bottom hooks of the mounting plate Make sure that the wires do NOT get squeezed anywhere Note Take care that the interconnection cable does N...

Page 10: ...ecified wires are used for the interconnection cable The indoor unit receives the signals of the user interface There are NO loose connections or damaged electrical components in the switch box The in...

Page 11: ...diode HAP Light emitting diode service monitor green HIGH VOLTAGE High voltage IES Intelligent eye sensor IPM Intelligent power module K R KCR KFR KHuR K M Magnetic relay L Live L Coil L R Reactor Sym...

Page 12: ...suyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe stanbul T RK YE Factory Kargal hanbaba OSB Mahallesi Organize Sanayi 1 Sokak No 28 54300 Hendek Sakarya T RK YE 3P482320 15Z 2021 10...

Reviews: