![Daikin Emura FTXJ-MW Installation Manual Download Page 4](http://html1.mh-extra.com/html/daikin/emura-ftxj-mw/emura-ftxj-mw_installation-manual_4702156004.webp)
4 About the unit
Installation manual
4
FTXJ35MV1BS/W6
Split system air conditioners
3P482320-15Z – 2021.10
▪ the mounting plate attached to the back of the indoor unit,
▪ the spare SSID sticker located on the front grille.
1×
2×
2×
2×
1×
1×
1×
1×
1×
1×
1×
f
d
e
b
a
c
g h
i
j
k
a
Installation manual
b
Operation manual
c
General safety precautions
d
Spare SSID sticker
e
Titanium apatite deodorising filter and silver allergen
removal air purifying filter (with frame)
f
Indoor unit fixing screw (M4×12L). Refer to
g
Dry battery AAA.LR03 (alkaline) for user interface
h
User interface holder
i
User interface
j
Mounting plate
k
Energy label
▪
Spare SSID sticker.
Do NOT throw away the spare sticker. Keep
it in a safe place in case it is needed in future (e.g. in case the
front grille was replaced attach it to the new front grille).
4
About the unit
WARNING: MILDLY FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
4.1
Operation range
Use the system in the following temperature and humidity ranges for
safe and effective operation.
Operation mode
Operation range
Cooling
(a)(b)
▪ Outdoor temperature: 10~46°C DB
▪ Indoor temperature: 18~32°C DB
▪ Indoor humidity: ≤80%
Heating
(a)
▪ Outdoor temperature: –15~24°C DB
▪ Indoor temperature: 10~30°C DB
Drying
(a)
▪ Outdoor temperature: 10~46°C DB
▪ Indoor temperature: 18~32°C DB
▪ Indoor humidity: ≤80%
(a)
A safety device might stop the operation of the system if the unit
runs outside its operation range.
(b)
Condensation and water dripping might occur if the unit runs
outside its operation range.
4.2
About the wireless LAN
For detailed specifications, installation instructions, setting methods,
FAQ, declaration of conformity and the latest version of this manual,
visit
.
INFORMATION
▪ Daikin Industries Czech Republic s.r.o. declares that
the radio equipment type inside of this unit is in
compliance with Directive 2014/53/EU.
▪ This unit is considered as combined equipment
according to the definition of Directive 2014/53/EU.
4.2.1
Precautions when using the wireless LAN
Do NOT use near:
▪
Medical equipment.
E.g. persons using cardiac pacemakers or
defibrillators.
This
product
may
cause
electromagnetic
interference.
▪
Auto-control equipment.
E.g. automatic doors or fire alarm
equipment. This product may cause faulty behaviour of the
equipment.
▪
Microwave oven.
It may affect wireless LAN communications.
4.2.2
Basic parameters
What
Value
Frequency range
2400 MHz~2483.5 MHz
Radio protocol
IEEE 802.11b/g/n
Radio frequency channel
1~13
Output power
13 dBm
Effective radiated power
15 dBm (11b) / 14 dBm (11g) /
14 dBm (11n)
Power supply
DC 14 V / 100 mA
5
Unit installation
INFORMATION
If you are not sure how to open or close parts of the unit
(front panel, electrical wiring box, front grille…) refer to the
installer reference guide of the unit for opening and closing
procedures.
WARNING
Installation shall be done by an installer, the choice of
materials and installation shall comply with the applicable
legislation. In Europe, EN378 is the applicable standard.
5.1
Preparing the installation site
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (e.g. open flames, an operating
gas appliance, or an operating electric heater). The room
size shall be as specified in the General safety precaution.
5.1.1
Installation site requirements of the
indoor unit
INFORMATION
The sound pressure level is less than 70 dBA.
▪
Air flow.
Make sure nothing blocks the air flow.
▪
Drainage.
Make sure condensation water can be evacuated
properly.