background image

4 Installation

Installation manual

3

EKMBU EKMBUHCA9W1
Daikin Altherma low temperature monobloc backup heater
4P405547-1C – 2015.08

>50

>50

>200

>500

>350

INFORMATION

If  the  backup  heater  is  installed  in  a  reversible  system
(07CAV3) and valve kit EKMBHBP1 is part of the
system,  it  may  be  required  to  provide  more  space  under
the  backup  heater  than  indicated  above.  For  more
information, refer to the installer reference guide and to the
documentation of the valve kit.

▪ The  backup  heater  is  designed  to  be  wall-mounted  in  indoor

locations  only.  Make  sure  the  installation  surface  is  a  flat  and
vertical non-combustible wall.

▪ The  backup  heater  is  designed  to  operate  in  ambient

temperatures ranging from 5~30°C.

3.2

Preparing water piping

When  installing  the  backup  heater  in  the  system,  make  sure  the
required  minimum  water  flow  rate  is  guaranteed  at  all  times.  For
more information, refer to the installation manual of the outdoor unit.

3.3

Preparing electrical wiring

3.3.1

Overview of electrical connections for
external and internal actuators

Item

Description

Wires

Maximum

running

current

Interconnection cable

1

Backup heater kit
thermistor

2

(a)

2

Backup heater kit
thermal protector

2

(a)

3

Backup heater kit
connection (from
control box)

2 (3V3)

3 (6V3, 6W1,
9W1)

(a)

(a)

Minimum cable section: 0.75 mm

2

; maximum length: 10 m.

Backup heater

Power supply

Required number of

conductors

EKMBUHCA3V3 1× 230 V

2+GND

EKMBUHCA9W1 1× 230 V

2+GND+2 bridges

3× 400 V

4+GND

NOTICE

More  technical  specifications  of  the  different  connections
are indicated on the inside of the backup heater.

4

Installation

4.1

Opening the units

4.1.1

To open the backup heater

2

1

4.1.2

To open the switch box cover of the
backup heater

1

2

4.2

Mounting the backup heater

4.2.1

To install the backup heater

1

Fix the wall bracket to the wall with M5 screws.

Summary of Contents for EKMBUHCA3V3

Page 1: ...Installation manual Daikin Altherma low temperature monobloc backup heater English Installation manual Daikin Altherma low temperature monobloc backup heater EKMBUHCA3V3 EKMBUHCA9W1 ...

Page 2: ... manual Installation instructions Format Paper in the box of the outdoor unit Control box installation manual Installation instructions Format Paper in the box of the control box Option box installation manual Installation instructions Format Paper in the box of the option box Backup heater installation manual Installation instructions Format Paper in the box of the backup heater Installer referen...

Page 3: ...d minimum water flow rate is guaranteed at all times For more information refer to the installation manual of the outdoor unit 3 3 Preparing electrical wiring 3 3 1 Overview of electrical connections for external and internal actuators Item Description Wires Maximum running current Interconnection cable 1 Backup heater kit thermistor 2 a 2 Backup heater kit thermal protector 2 a 3 Backup heater ki...

Page 4: ... m 1 Connect the water piping field supply to the water in and outlet of the backup heater b a a Water inlet b Water outlet NOTICE When the backup heater is installed in a reversible system EBLQ05 07CAV3 and below conditions are met see illustration condensation may occur inside the backup heater To provide a bypass for the condensate install valve kit EKMBHBP1 Do NOT install any other valve kit t...

Page 5: ...rt of the system use a dedicated power circuit for the backup heater and booster heater NEVER use a power circuit shared by another appliance This power circuit must be protected with the required safety devices according to the applicable legislation Depending on the model the backup heater capacity can vary Make sure that the power supply is in accordance with the backup heater capacity as liste...

Page 6: ... 8Ω 105 8Ω K1M 5 105 8Ω 105 8Ω K1M 3 K1M 5 26 5Ω 26 5Ω 105 8Ω 105 8Ω K2M 1 K5M 13 26 5Ω K2M 3 52 9Ω 52 9Ω K2M 5 52 9Ω 52 9Ω K2M 3 K2M 5 52 9Ω 52 9Ω 52 9Ω 52 9Ω K1M 5 K2M 1 Example measure resistance between K1M 1 and K5M 13 K1M K2M K2M 1 3 5 13 2 4 6 14 K5M 1 3 5 13 2 4 6 14 1 3 5 13 2 4 6 14 Ω Ω 4 4 3 To connect the backup heater kit to the control box 1 For the thermistor connect 2 wires between...

Page 7: ......

Page 8: ...4P405547 1C 2015 08 Copyright 2015 Daikin ...

Reviews: