background image

Table of Contents

Installation manual

2

EKMBU EKMBUHCA9W1

Daikin Altherma low temperature monobloc backup heater

4P405547-1C – 2015.08

Table of Contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 About the box

2

2.1

Backup heater ...........................................................................

2

2.1.1

To remove the accessories from the backup heater...

2

3 Preparation

2

3.1

Preparing installation site ..........................................................

2

3.1.1

Installation site requirements of the backup heater ....

2

3.2

Preparing water piping ..............................................................

3

3.3

Preparing electrical wiring .........................................................

3

3.3.1

Overview of electrical connections for external and
internal actuators ........................................................

3

4 Installation

3

4.1

Opening the units ......................................................................

3

4.1.1

To open the backup heater .........................................

3

4.1.2

To open the switch box cover of the backup heater ...

3

4.2

Mounting the backup heater......................................................

3

4.2.1

To install the backup heater........................................

3

4.3

Connecting the water piping......................................................

4

4.3.1

To connect the water piping to the backup heater ......

4

4.4

Connecting the electrical wiring.................................................

5

4.4.1

To connect the electrical wiring on the backup heater

5

4.4.2

To connect the backup heater power supply ..............

5

4.4.3

To connect the backup heater kit to the control box ...

6

5 Starting up the system

6

1

About the documentation

1.1

About this document

Target audience

Authorised installers

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the outdoor unit)

Outdoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Control box installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the control box)

Option box installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the option box)

Backup heater installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the backup heater)

Installer reference guide:

▪ Preparation  of  the  installation,  technical  specifications,  good

practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Addendum book for optional equipment:

▪ Additional info about how to install optional equipment

▪ Format: Paper (in the box of the outdoor unit) + Digital files on

http://www.daikineurope.com/support-and-manuals/product-
information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

2

About the box

2.1

Backup heater

NOTICE

▪ The backup heater is an option and can only be used in

combination  with  outdoor  units  07CAV3  and
07CAV3.

▪ To be able to use the backup heater, it is required that

optional  control  box  EKCB07CAV3  is  part  of  the
system.

2.1.1

To remove the accessories from the
backup heater

1

Remove the wall bracket from the box.

3

Preparation

3.1

Preparing installation site

3.1.1

Installation site requirements of the
backup heater

▪ Mind the measurement guidelines:

Maximum distance between the backup heater and
the outdoor unit

10 m

▪ Mind the following spacing installation guidelines:

Summary of Contents for EKMBUHCA3V3

Page 1: ...Installation manual Daikin Altherma low temperature monobloc backup heater English Installation manual Daikin Altherma low temperature monobloc backup heater EKMBUHCA3V3 EKMBUHCA9W1 ...

Page 2: ... manual Installation instructions Format Paper in the box of the outdoor unit Control box installation manual Installation instructions Format Paper in the box of the control box Option box installation manual Installation instructions Format Paper in the box of the option box Backup heater installation manual Installation instructions Format Paper in the box of the backup heater Installer referen...

Page 3: ...d minimum water flow rate is guaranteed at all times For more information refer to the installation manual of the outdoor unit 3 3 Preparing electrical wiring 3 3 1 Overview of electrical connections for external and internal actuators Item Description Wires Maximum running current Interconnection cable 1 Backup heater kit thermistor 2 a 2 Backup heater kit thermal protector 2 a 3 Backup heater ki...

Page 4: ... m 1 Connect the water piping field supply to the water in and outlet of the backup heater b a a Water inlet b Water outlet NOTICE When the backup heater is installed in a reversible system EBLQ05 07CAV3 and below conditions are met see illustration condensation may occur inside the backup heater To provide a bypass for the condensate install valve kit EKMBHBP1 Do NOT install any other valve kit t...

Page 5: ...rt of the system use a dedicated power circuit for the backup heater and booster heater NEVER use a power circuit shared by another appliance This power circuit must be protected with the required safety devices according to the applicable legislation Depending on the model the backup heater capacity can vary Make sure that the power supply is in accordance with the backup heater capacity as liste...

Page 6: ... 8Ω 105 8Ω K1M 5 105 8Ω 105 8Ω K1M 3 K1M 5 26 5Ω 26 5Ω 105 8Ω 105 8Ω K2M 1 K5M 13 26 5Ω K2M 3 52 9Ω 52 9Ω K2M 5 52 9Ω 52 9Ω K2M 3 K2M 5 52 9Ω 52 9Ω 52 9Ω 52 9Ω K1M 5 K2M 1 Example measure resistance between K1M 1 and K5M 13 K1M K2M K2M 1 3 5 13 2 4 6 14 K5M 1 3 5 13 2 4 6 14 1 3 5 13 2 4 6 14 Ω Ω 4 4 3 To connect the backup heater kit to the control box 1 For the thermistor connect 2 wires between...

Page 7: ......

Page 8: ...4P405547 1C 2015 08 Copyright 2015 Daikin ...

Reviews: