EKHBRD011~Y1

Indoor unit for air to water heat pump system and options

4PW60971-1

Operation manual

2

Q

UICK

 

START

-

UP

 

OF

 

THE

 

UNIT

In this chapter the step-by-step procedure is explained for starting up
both space heating and domestic water heating.

The more detailed information of how the unit must be operated is
explained in the chapter "Operation of the unit" on page 2.

The quick start-up offers the user the possibility to start up the
system before reading the entire manual.

Space heating operation

Domestic water heating operation

Manual storage

O

PERATION

 

OF

 

THE

 

UNIT

The remote controller offers full control over your installation. It can
control all heating applications which vary in capacity, electrical
supply and installed equipment (options). Operating the EKHBRD
unit comes down to operating the remote controller.

Push the 

bi

 or 

bj

 button

Display: 

8

8

8

88

8

8

8....8

8

8

8

 starts 

blinking

Display: "

n

"

Set desired room 

temperature (e.g. 22°C)

The remote controller 

room thermostat 

function is not installed

Push the 

ébi

 or 

ébj

 

button

You have "room 

temperature based" 

control of your system 

(remote controller 

room thermostat is 

installed)

You have "leaving water 

temperature based" control 

of your system

Set desired leaving water 

temperature (e.g. 65°C)

If the display is blank, 

automatic leaving water 

temperature is enabled

Push the 

y

 button

The 

0

 LED will light up and the 

unit will start

For further details and advised 

settings, see "Space heating 

operation (

h

h

h

h

)" on page 4.

Domestic water heating (only if domestic hot water tank option is installed)

Automatic storage (daily water heat-up, once during night and/or once during 
day)

Turn on 

fi

eld setting [1-00] 

and or [1-02] and then push 
the 

rp

 button.

See "Automatic storage" on 
page 7.

The 

p

 icon will display.

Hot water will be produced at next scheduled 
action.
When water heat-up starts, the 

w

 icon will 

be blinking (1 second interval).

Manual storage (one time water heat-up)(refer to scheme below)

Push and hold the 

w

 button 

for 5 seconds.
See "Manual storage" on 
page 7.

The 

w

 icon will start blinking (1 second 

interval).
Hot water will be produced.

Reheat (continuous, keeping the minimum water temperature)

Push the 

w

 button 1 time.

See "Reheat" on page 8.

Hot water will be produced if the domestic hot 
water tank temperature is below the selected 
value.
Water will be heated up until the selected 
value is reached.

Push and hold the 

w

 button for 

5 seconds

Display: 

icon starts blinking

Display: "

n

"

Your water will be heated till 

storage set point (one time action)

The domestic hot water tank is not 

installed

For further details and advised 

settings, see "Domestic water 

heating operation (

w

w

w

w

)" on 

page 6

NOTE

It is advised to use the remote controller, which
includes room thermostat function, delivered with the
unit.

This will prevent excessive space heating and will stop
the outdoor and indoor unit when the room
temperature is above the thermostat set point. Based
on the request from the user there is an immediate
feedback to the compressor control which optimizes
the performance.

Refer to the typical application examples in the indoor
installation manual for more details.

Never let the remote controller get wet. This may
cause an electric shock or 

fi

re.

Never press the buttons of the remote controller with a
hard, pointed object. This may damage the remote
controller.

Never inspect or service the remote controller
yourself, ask a quali

fi

ed service person to do this.

Do not rinse the indoor unit. This may cause electric
shock or 

fi

re.

Do not climb, sit or stand on top of the unit.

Do not place any objects or equipment on the unit top
plate.

Summary of Contents for EKHBRD014ABV1

Page 1: ...OPERATION MANUAL EKHBRD011ABV1 EKHBRD014ABV1 EKHBRD016ABV1 EKHBRD011ABY1 EKHBRD014ABY1 EKHBRD016ABY1 Indoor unit for air to water heat pump system and options...

Page 2: ...es or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to...

Page 3: ...e rp button See Automatic storage on page 7 The p icon will display Hot water will be produced at next scheduled action When water heat up starts the w icon will be blinking 1 second interval Manual s...

Page 4: ...used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficien...

Page 5: ...seconds the display will show to the actual room temperature 32 QUIET MODE BUTTON s This button enables or disables quiet mode If the controller is set to permission level 2 or 3 refer to Field setti...

Page 6: ...oor temperatures will result in warmer water and vice versa The unit has a floating set point Activating this operation will result in a lower power consumption than use with a manually fixed leaving...

Page 7: ...k function is turned ON 1 or OFF 0 2 01 Start time time at which setback is started 2 02 Stop time time at which setback is stopped 5 02 Leaving water setback temperature temperature drop Domestic wat...

Page 8: ...storage temperature set point is reached It is a one time hot water making feature Selecting manual storage operation for domestic water heating 1 Push and hold the w button for 5 seconds to activate...

Page 9: ...er Field settings on page 15 for a detailed description how to set one or more field settings 4 00 Status defines whether the disinfection function is turned ON 1 or OFF 0 4 01 Operation interval day...

Page 10: ...multaneous demand of space heating and domestic water heating The unit can not perform domestic water heating and space heating at the same time If both modes are requested at the same time the unit w...

Page 11: ...eating stays enabled When pushing the r p button The schedule timer for space heating and domestic water heating along with the quiet mode will be stopped and will not start again The schedule timer i...

Page 12: ...tion 3 When both setback function and schedule timer are enabled A Setback function B ON OFF instruction t Time T Temperature set point Room temperature Leaving water temperature t 18 18 C 60 60 C 60...

Page 13: ...e repeated on a weekly basis In the domestic water heating and quiet mode program depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a dail...

Page 14: ...s the button for 5 seconds to store the programmed actions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted You automatically return to s...

Page 15: ...step 2 by pressing the pr button 5 Press the and pr buttons simultaneously for 5 seconds After 5 seconds the display will show the next day e g 2 if 1 was selected first This indicates that the day h...

Page 16: ...Press the z button for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed to the right 1 2...

Page 17: ...10 20 1 C 02 Set point at low ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 D...

Page 18: ...age temperature 70 45 75 1 C 04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation relate...

Page 19: ...yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation Units must b...

Page 20: ...NOTES...

Page 21: ...NOTES...

Page 22: ...NOTES...

Page 23: ......

Page 24: ...4PW60971 1 Copyright 2010 Daikin...

Reviews: