EKHBH/X016AB

Indoor unit for hot water heat pump system and options

Operation manual

6

Selecting powerful domestic water heating operation

1

Press 

v

  for 5 seconds to activate powerful domestic water

heating operation.
Icons 

w

 and 

m

 start flashing.

Powerful domestic water heating is deactivated automatically
when the set point for the domestic hot water is reached.

Selecting quiet mode operation (

s

)

1

Use the 

s

 button to activate quiet mode operation (

s

).

Icon 

s

 appears on the display.

If the controller is set in permission level 2 or 3 (refer to 

"Field

settings" on page 10

), the 

s

 button will not be operable.

Selecting weather dependent set point operation (only in
heating mode)

1

Press the 

ba

  button to select weather dependent set point

operation.
Icon 

a

  appears on the display as well as the shift value. The

shift value is not shown in case it is 0.

2

Use the 

bi

 and 

bj

 buttons to set the shift value.

Range for the shift value: –5°C to +5°C

Displaying actual temperatures

1

Push the 

ba

 button for 5 seconds.

The 

b

 icon and the outgoing water temperature are displayed.

The icons 

l

 and 

=

 are flashing.

2

Use the 

pi

 and 

pj

 buttons to display:

The outdoor temperature (

u

 icon is flashing).

The domestic hot water tank temperature (

w

  icon is

flashing).

The outgoing water temperature (

=

 are flashing).

If no button is pressed for 5 seconds, the controller leaves the
display mode.

Schedule timer operation

In schedule timer operation, the installation is controlled by the
schedule timer. The actions programmed in the schedule timer will be
executed automatically.

The schedule timer always follows the last command until a new
command is given. This means that the user can temporarily overrule
the last executed programmed command by manual operation (Refer
to 

"Manual operation" on page 5

). The schedule timer will regain

control over the installation as soon as the next programmed
command of the schedule timer occurs.

The schedule timer is enabled (

p

 icon displayed) or disabled (

p

 icon

not displayed), by pressing the 

pr

 button.

To set up the SCHEDULE TIMER refer to chapter 

"Programming and

consulting the schedule timer" on page 7

.

What can the schedule timer do?

The schedule timer allows the programming of:

1

Space heating and space cooling (refer to 

"Programming space

cooling or space heating" on page 8

)

Switch on the desired mode at a scheduled time, in combination
with a set point (weather dependent or manually set). Five
actions per weekday can be programmed, totalling 35 actions.

2

Quiet mode (refer to 

"Programming quiet mode, booster heating

or domestic water heating" on page 9

)

Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.

3

Booster heating (refer to 

"Programming quiet mode, booster

heating or domestic water heating" on page 9

)

Allow or disallow booster heating at a scheduled time. Five
actions can be programmed per mode. These actions are
repeated daily.

4

Domestic water heating (refer to 

"Programming quiet mode,

booster heating or domestic water heating" on page 9

)

Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.

NOTE

Remark that pushing the 

y

 button has no influence

on the domestic water heating. Domestic water
heating is only switched on or off by means of the 

v

button.

NOTE

Only use the 

pr

 button to enable or disable the

schedule timer. The schedule timer overrules the

y

  button. The 

y

  button only overrules the

schedule timer until the next programmed action.

If the auto restart function is disabled, the
schedule timer will not be activated when power
returns to the unit after a power supply failure.
Press the 

pr

 button to enable the schedule timer

again.

When power returns after a power supply failure,
the auto restart function reapplies the user
interface settings at the time of the power supply
failure.

It is therefore recommended to leave the auto
restart function enabled.

The programmed schedule is time driven. Therefore, it
is essential to set the clock and the day of the week
correctly. Refer to 

"Setting the clock" on page 4

.

Manually adjust the clock for summertime and
wintertime. Refer to 

"Setting the clock" on page 4

.

A power failure exceeding 1 hour will reset the clock
and the day of the week. The schedule timer will
continue operation, but with a disordered clock. Refer
to 

"Setting the clock" on page 4

  to adjust the clock

and the day of the week.

The actions programmed in the schedule timer will not
be lost after a power failure so that reprogramming the
schedule timer is not required.

NOTE

When the unit is connected to an external room
thermostat, the schedule timer for space cooling and
space heating is overruled by the external room
thermostat.

The programmed actions are not stored according to
their timing but according to the time of programming.
This means that the action that was programmed first
gets action number 1, even though it is executed after
other programmed action numbers.

When the schedule timer switches space heating or
space cooling 

x

, the controller will also be

switched off. Note that this has no influence on
domestic water heating.

Summary of Contents for EKHBH016AB

Page 1: ...OPERATION MANUAL EKHBH016AB EKHBX016AB Indoor unit for hot water heat pump system and options ...

Page 2: ...mbined with Daikin fan coil units floor heating low temperature radiators the Daikin domestic hot water tanks and the solar option kit The hot water heat pump system indoor unit range consists of two main versions a heating cooling EKHBX version and a heating only EKHBH version Both versions can optionally be delivered with an integrated backup heater for additional heating capacity during cold ou...

Page 3: ...ow electricity cost tariffs in mind To do this program both the domestic water heating and booster heating schedule timer Refer to Programming in chapter Programming and consulting the schedule timer on page 7 OPERATING THE DIGITAL CONTROLLER Operating the EKHB unit comes down to operating the digital controller Features and functions The digital controller is a state of the art controller that of...

Page 4: ...ected when programming the schedule timer 10 INSPECTION REQUIRED k and l These icons indicate that inspection is required on the installation Consult your Daikin dealer 11 SET TEMPERATURE DISPLAY 9 The display shows the current set temperature of the installation 12 SETTING Not used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whenever a non installed option is addresse...

Page 5: ...he domestic hot water tank is not installed 34 QUIET MODE BUTTON s This button enables or disables quiet mode If the controller is set in permission level 2 or 3 refer to Field settings on page 10 the quiet mode button will not be operable Setting up the controller After initial installation the user can set the clock and day of the week The controller is equipped with a schedule timer that enable...

Page 6: ...perable when the outdoor ambient temperature rises above a certain temperature as set through field setting 4 02 refer to Field settings on page 10 Temperature range for cooling 5 C to 22 C 3 Switch on the unit by pushing the y button The operation LED 0 lights up Selection and setting of domestic water heating w 1 Use the v button to activate domestic water heating w Icon w appears on the display...

Page 7: ...ions 2 Quiet mode refer to Programming quiet mode booster heating or domestic water heating on page 9 Switch the mode on or off at a scheduled time Five actions can be programmed per mode These actions are repeated daily 3 Booster heating refer to Programming quiet mode booster heating or domestic water heating on page 9 Allow or disallow booster heating at a scheduled time Five actions can be pro...

Page 8: ...ement but will simplify the interpretation of the program later If 2 or more actions are programmed for the same day and at the same time only the action with the highest action number will be executed You can always alter add or remove the programmed actions later When programming heating actions time and set point cooling actions are added automatically at the same time but with the predefined d...

Page 9: ...t x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the pi and pj buttons to set the correct action time 11 Repeat steps 8 to 10 to program the other actions of the selected day When all actions have been programmed make sure that the display shows the highest actio...

Page 10: ...ult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the pi and pj buttons The selected day is blinking 5 Press the button to confirm the selected day The first programmed action of the selected day appears 6 Use the pi and pj buttons to consult the other programmed actio...

Page 11: ...aneously for 5 seconds to delete the selected mode Deleting a day of the week cooling or heating mode 1 Use the button to select the operation mode cooling or heating you want to delete 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to delete by means of the pi and pj buttons The selected day...

Page 12: ...ld be higher than Hi_Ti as for colder outdoor temperatures i e Lo_A warmer water is required 1 03 Set point at high ambient temperature Hi_Ti the target outgoing water temperature when the outdoor temperature equals or rises above the high ambient temperature Hi_A Note that the Hi_Ti value should be lower than Lo_Ti as for warmer outdoor temperatures i e Hi_A less warm water suffices 2 Disinfectio...

Page 13: ...atus specifies whether space heating priority is enabled 1 or disabled 0 5 03 Space heating priority temperature outdoor temperature below which the domestic water will be heated by the booster heater only i e low outdoor temperature 5 04 Set point correction for domestic hot water temperature set point correction for the desired domestic hot water temperature to be applied at low outdoor temperat...

Page 14: ...hed Note that when the unit is configured to work with a room thermostat refer to the installation manual the maximum running timer will only be taken into account when there is a request for space cooling or space heating When there is no request for room cooling or room heating domestic water heating by the heat pump will continue until the heat pump OFF temperature see field settings 5 is reach...

Page 15: ...iet operation might be overridden when higher performance is required In certain cases this might result in less quiet operation of the outdoor unit to meet the requested performance A 00 Quiet mode type defines whether quiet mode A 0 or quiet mode B 2 is selected A 01 Parameter 01 do not change this setting Leave it set to its default value C Solar priority mode For information concerning the EKS...

Page 16: ...5 1 C 5 Equilibrium temperature and space heating priority temperature 00 Equilibrium temperature status 1 ON 0 1 01 Equilibrium temperature 0 15 20 1 C 02 Space heating priority status 0 OFF 0 1 03 Space heating priority temperatures 0 15 20 1 C 04 Set point correction for domestic hot water temperature 10 0 20 1 C 6 DT for domestic water heating 00 Start 5 1 20 1 C 01 Stop 2 2 10 1 C 7 Domestic ...

Page 17: ...r local Daikin dealer The schedule timer does work but the programmed actions are executed at the wrong time e g 1 hour too late or too early Check if the clock and the day of the week are set correctly correct if necessary DISPOSAL REQUIREMENTS Dismantling of the unit treatment of the refrigerant of oil and of other parts must be done in accordance with relevant local and national legislation Do ...

Page 18: ...NOTES NOTES ...