![Daikin EKHBH016AB Operation Manual Download Page 16](http://html.mh-extra.com/html/daikin/ekhbh016ab/ekhbh016ab_operation-manual_502182016.webp)
Operation manual
15
EKHBH/X016AB
Indoor unit for hot water heat pump system and options
Field settings table
First
code
Second
code
Setting name
Installer setting at variance with default value
Default
value
Range
Step
Unit
Date
Value
Date
Value
0
User permission level
00
User permission level
3
2~3
1
—
1
Weather dependent set point
00
Low ambient temperature (Lo_A)
–10
–20~5
1
°C
01
High ambient temperature (Hi_A)
15
10~20
1
°C
02
Set point at low ambient temperature (Lo_TI)
40
25~55
1
°C
03
Set point at high ambient temperature (Hi_TI)
25
25~55
1
°C
2
Disinfection function
00
Operation interval
Fri
Mon~Sun,
All
—
—
01
Status
1 (ON)
0/1
—
—
02
Start time
23:00
0:00~23:00
1:00
hour
03
Set point
70
40~80
5
°C
04
Interval
10
5~60
5
min
3
Auto restart
00
Status
0 (ON)
0/1
—
—
4
Backup heater operation and space heating off temperature
00
Status
1 (ON)
0/1
—
—
01
Priority
0 (OFF)
0/1
—
—
02
Space heating off temperature
35
14~35
1
°C
5
Equilibrium temperature and space heating priority temperature
00
Equilibrium temperature status
1 (ON)
0/1
—
—
01
Equilibrium temperature
0
–15~20
1
°C
02
Space heating priority status
0 (OFF)
0/1
—
—
03
Space heating priority temperatures
0
–15~20
1
°C
04
Set point correction for domestic hot water
temperature
10
0~20
1
°C
6
DT for domestic water heating
00
Start
5
1~20
1
°C
01
Stop
2
2~10
1
°C
7
Domestic hot water step length
00
Domestic hot water step length
3
2~4
1
°C
8
Domestic water heating mode timer
00
Minimum running time
5
0~20
1
min
01
Maximum running time
30
5~95
5
min
02
Anti-recycling time
3
0~10
0.5
hour
03
Booster heater delay time
20
20~95
5
min
9
Cooling and heating set point ranges
00
Heating set point upper limit
55
37~55
1
°C
01
Heating set point lower limit
15/25
(a)
15~37
1
°C
02
Cooling set point upper limit
20
18~22
1
°C
03
Cooling set point lower limit
5
5~18
1
°C
A
Quiet mode
00
Quiet mode type
0
0/2
—
—
01
Parameter 01
3
—
—
—
C
Solar priority mode
00
Solar priority mode setting
0
0~2
1
—
(a) With optional backup heater installed: 15°C. Without optional backup heater installed: 25°C