![Daikin EHYHBH05AAV3 Service Manual Download Page 34](http://html1.mh-extra.com/html/daikin/ehyhbh05aav3/ehyhbh05aav3_service-manual_4358735034.webp)
Wiring Diagrams
ESIE13-02A
Part 1 System Outline
34
3
11
4
5
3.2
Overview Switch Box
The next two figures ("PCB: part 1" and "PCB: part 2") show the wiring diagram of the hybrid PCB. The
different components are mentioned either on "PCB: part 1" or on "PCB: part 2. The legend that is
attached mentions the description of each part number and can help to understand these two figures.
Some additional information on the PCB figures:
The
contacts S1S, S2S and S3S
, shown on PCB PART 1, fulfil the following functions:
S1S: Preferential kWh rate: can force the outdoor heat pump to switch off.
S2S: Electric power meter pulse input (for the purpose of energy metering).
S3S: Gas meter pulse input (for the purpose of energy metering).
The
user interface
(A2P, see drawing "PCB: PART 1"): is delivered as an accessory within the
unit. The connection diagram (see further) shows how to connect it to the PCB.
Part number
Description
A4P
Digital I/O PCB, receiver PCB (wireless ON/OFF thermostat, PC= power circuit)
(optional)
A8P
Demand PCB (optional)
TR1, TR2
Power supply transformer
A1P
Main PCB (hydro)
X*Y
Connector
X*M
Terminal strip
Summary of Contents for EHYHBH05AAV3
Page 16: ...Introduction ESIE13 02A 16 3 1 4 5...
Page 29: ...ESIE13 02A Functionality 29 Part 1 System Outline 3 1 4 5...
Page 30: ...Functionality ESIE13 02A Part 1 System Outline 30 3 1 1 4 5...
Page 35: ...ESIE13 02A Wiring Diagrams 35 Part 1 System Outline 3 1 4 5...
Page 36: ...Wiring Diagrams ESIE13 02A Part 1 System Outline 36 3 1 1 4 5...
Page 38: ...Wiring Diagrams ESIE13 02A Part 1 System Outline 38 3 1 1 4 5 3 3 Cable Dimensions...
Page 39: ...ESIE13 02A Wiring Diagrams 39 Part 1 System Outline 3 1 4 5...
Page 50: ...Outdoor Unit ESIE13 02A Part 2 Specifications 50 3 1 2 5...
Page 51: ...ESIE13 02A 51 Part 3 Commissioning 4 3 4 5 3 Part 3 Commissioning See Note on page 6...
Page 52: ...ESIE13 02A Part 3 Commissioning 52 3 1 3 5...
Page 98: ...Error Codes Hydro box ESIE13 02A Part 4 Troubleshooting 98 3 1 4 5 Troubleshooting...
Page 115: ...ESIE13 02A Error Codes Outdoor Units 115 Part 4 Troubleshooting 4 3 4 5 4 Troubleshooting...
Page 170: ...Maintenance Schedule ESIE13 02A Part 6 Maintenance 170 3 1 6...