2 About the system

Operation manual

3

EHVH04~26CB6W
Daikin Altherma – Low temperature split
4P449982-1 – 2016.06

2

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Produce domestic hot water

2.1

Components in a typical system
layout

d

a

b

c

e

f

g

B

C

A

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Indoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface at the indoor unit

e

User interface in the living room, used as room thermostat

f

Underfloor heating

g

Heat pump convectors or fan coil units

3

Operation

3.1

Overview: Operation

You  can  operate  the  system  via  the  user  interface.  This  part
describes how to use the user interface:

Part

Description

At a glance

▪ Buttons

▪ Status icons

Space heating control

How to control space heating:

▪ Setting the space operation mode

▪ Controlling the temperature

Domestic hot water
control

How to control domestic hot water:

▪ Reheat mode

▪ Scheduled mode

▪ Sch reheat mode

Schedules

How to select and program schedules

Menu structure

Overview of menu structure

Installer settings table

Overview of installer settings

3.2

The user interface at a glance

3.2.1

Buttons

a

e

f

b

d

c

a

 HOME PAGES

▪ Switches between home pages (when you are on a home

page).

▪ Goes to the default home page (when you are in the menu

structure).

b

 MALFUNCTION INFORMATION

If a malfunction occurs,   is displayed on the home pages.
Press 

 to display more information about the malfunction.

c

 ON/OFF

Turns  ON  or  OFF  one  of  the  controls  (room  temperature,
leaving water temperature, DHW tank temperature).

d

 MENU STRUCTURE/BACK

▪ Opens  the  menu  structure  (when  you  are  on  a  home

page).

▪ Goes  up  a  level  (when  you  are  navigating  through  the

menu structure).

▪ Goes back 1 step (example: when you are programming a

schedule in the menu structure).

e

 

 

 

 NAVIGATING/CHANGING SETTINGS

▪ Navigates the cursor on the display.
▪ Navigates through the menu structure.
▪ Changes settings.
▪ Selects a mode.

f

 OK

▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches between displaying actual and desired values, or

between  displaying  actual  and  offset  values  (if  applicable)
on the home pages.

▪ Goes  to  the  next  step  (when  you  are  programming  a

schedule in the menu structure).

▪ Enables you to activate or deactivate button lock if pressed

for more than 5 seconds on a home page.

▪ Enables  you  to  activate  or  deactivate  a  function  lock  if

pressed for more than 5 seconds in the main menu of the
menu structure.

INFORMATION

If you press 

 or 

 while changing settings, the changes

will NOT be applied.

Summary of Contents for EHVH04SU18CB6W

Page 1: ...Operation manual Daikin Altherma Low temperature split English Operation manual Daikin Altherma Low temperature split EHVH04SU18CB6W EHVH08SU18CB6W EHVH08SU26CB6W EHVH11SU26CB6W EHVH16SU26CB6W...

Page 2: ...document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you...

Page 3: ...er interface at a glance 3 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home page Goes to the default home page when you are in the menu structure b MALFUNCTION I...

Page 4: ...trol Using the room temperature home page Typical room temperature home pages Depending on the user profile the user interface gives you either a basic or a detailed home page To set the user profile...

Page 5: ...ed mode However when the DHW tank temperature drops below a preset value reheat tank temperature hysteresis value example 35 C the DHW tank heats up until it reaches the reheat set point example 45 C...

Page 6: ...schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below fo...

Page 7: ...Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Tempe...

Page 8: ...3 Booster heater 2 4 kW BUH step 1 3 kW BUH step 2 3 kW Bottom plate heater 0 W 3 8 2 Space heating control Setting Default Fill in Leaving water temperature Main zone A 3 1 1 LWT setpoint mode 1 WD L...

Page 9: ...ght is not sufficient program to additionally heat up the DHW tank to a preset value Storage eco lower DHW tank temperature during the day Make sure the desired DHW tank temperature is NOT too high Ex...

Page 10: ...set value Storage eco lower tank temperature during the day The desired DHW tank temperature is too low 6 3 Symptom Heat pump failure When the heat pump fails to operate the backup heater and booster...

Page 11: ......

Page 12: ...4P449982 1 0000000Y 4P449982 1 2016 06 Copyright 2016 Daikin...

Reviews: