3 Operation

Operation manual

4

EHVH04~26CB6W

Daikin Altherma – Low temperature split

4P449982-1 – 2016.06

3.2.2

Status icons

Icon

Description

Space operation mode = Heating.

Not available.

Unit is operating.

Desired room temperature = preset value (Comfort;
daytime).

Desired room temperature = preset value (Eco;
nighttime).

▪ On  the  room  temperature  home  page:  Desired

room  temperature  =  according  to  the  selected
schedule.

▪ On  the  DHW  tank  temperature  home  page:

DHW tank mode = Scheduled mode.

DHW tank mode = Reheat mode.

 

DHW tank mode = Sch reheat mode.

Domestic hot water operation.

Actual temperature.

Desired temperature.

At the next scheduled action, the desired temperature
will increase.

At the next scheduled action, the desired temperature
will NOT change.

At the next scheduled action, the desired temperature
will decrease.

The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.

The DHW tank booster mode is active or ready to be
activated.

Quiet mode is active.

Holiday mode is active or ready to be activated.

Button lock mode and/or function lock mode is active.

An external heat source is active. 

Example: 

Gas

burner.

The disinfection mode is active.

A malfunction occured. Press 

 to display more

information about the malfunction.

Weather-dependent mode is active.

User permission level = Installer.

Defrost/oil return mode is active.

Hot start mode is active.

Emergency operation is active.

3.3

Space heating control

3.3.1

Setting the space operation mode

About space operation modes

The heat pump is a heating only model. The system can heat up a
space, but NOT cool down a space.

3.3.2

Room thermostat control - Using the
room temperature home page

Typical room temperature home pages

Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  To  set  the  user  profile,  refer  to
Configuring  user  profile  and  home  pages  in  the  user  reference
guide.

User profile = Basic

User profile = Detailed

15:20

20.0°C

Mon

Room

Actual temperature

15:20

20.0°C

17:30

Actual temperature

Room

Scheduled

Mon

Tue

To read out the actual and desired room
temperature

1

Go to the room temperature home page (Room).

Result: 

You  can  read  out  the  actual  temperature.

20.0°C

Actual temperature

2

Press 

.

Result: 

You  can  read  out  the  desired  temperature.

22.0°C

Desired temperature

To temporarily overrule the room temperature
schedule

1

Go to the room temperature home page (Room).

2

Use 

 or 

 to adjust the temperature.

To change the mode from scheduled to preset
value

Prerequisite: 

User profile = Detailed.

1

Go to the room temperature home page (Room).

2

Press 

 or 

 to select a preset value (  or  ).

Result: 

The mode will return to Scheduled according to the overrule

period.

To set the overrule period

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [7.2]: 

 > User settings > Temperature lock.

2

Select a value and press 

:

▪ Permanent
▪ hours (2, 4, 6, 8)

3.3.3

Room thermostat control - Using the
leaving water temperature home pages

INFORMATION

The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.

Example: 

Underfloor heating is designed for lower leaving

water  temperature  than  radiators  and  heat  pump
convectors  and/or  fan  coil  units.  You  only  have  to  adjust
leaving water temperature settings in case of problems.

For  more  information  about  the  leaving  water  temperature,  see  the
user reference guide.

Summary of Contents for EHVH04SU18CB6W

Page 1: ...Operation manual Daikin Altherma Low temperature split English Operation manual Daikin Altherma Low temperature split EHVH04SU18CB6W EHVH08SU18CB6W EHVH08SU26CB6W EHVH11SU26CB6W EHVH16SU26CB6W...

Page 2: ...document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you...

Page 3: ...er interface at a glance 3 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home page Goes to the default home page when you are in the menu structure b MALFUNCTION I...

Page 4: ...trol Using the room temperature home page Typical room temperature home pages Depending on the user profile the user interface gives you either a basic or a detailed home page To set the user profile...

Page 5: ...ed mode However when the DHW tank temperature drops below a preset value reheat tank temperature hysteresis value example 35 C the DHW tank heats up until it reaches the reheat set point example 45 C...

Page 6: ...schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below fo...

Page 7: ...Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Tempe...

Page 8: ...3 Booster heater 2 4 kW BUH step 1 3 kW BUH step 2 3 kW Bottom plate heater 0 W 3 8 2 Space heating control Setting Default Fill in Leaving water temperature Main zone A 3 1 1 LWT setpoint mode 1 WD L...

Page 9: ...ght is not sufficient program to additionally heat up the DHW tank to a preset value Storage eco lower DHW tank temperature during the day Make sure the desired DHW tank temperature is NOT too high Ex...

Page 10: ...set value Storage eco lower tank temperature during the day The desired DHW tank temperature is too low 6 3 Symptom Heat pump failure When the heat pump fails to operate the backup heater and booster...

Page 11: ......

Page 12: ...4P449982 1 0000000Y 4P449982 1 2016 06 Copyright 2016 Daikin...

Reviews: