background image

Table of contents

Operation manual

2

EHBH/X04~16CB + EHVH/X04~16CB

Daikin Altherma – Low temperature split

4P383117­1C – 2015.01

Table of contents

1 About this document

2

2 About the system

2

2.1

Components in a typical system layout .....................................

2

3 Operation

3

3.1

Overview: Operation..................................................................

3

3.2

The user interface at a glance ...................................................

3

3.2.1

Buttons........................................................................

3

3.2.2

Status icons ................................................................

3

3.3

Space heating/cooling control ...................................................

4

3.3.1

Setting the space operation mode ..............................

4

3.3.2

Using the room temperature home page ....................

4

3.3.3

Using the leaving water temperature home pages
(main + additional) ......................................................

4

3.4

Domestic hot water control ........................................................

4

3.4.1

Reheat mode ..............................................................

4

3.4.2

Scheduled mode .........................................................

5

3.4.3

Sch reheat mode...........................................

5

3.4.4

Using the DHW tank temperature home page ............

5

3.4.5

Using the DHW tank booster mode ............................

5

3.5

Advanced usage........................................................................

5

3.5.1

About changing the user permission level ..................

5

3.6

Schedules: Example..................................................................

6

3.7

Menu structure: Overview user settings ....................................

7

3.8

Installer settings: Tables to be filled in by installer ....................

8

3.8.1

Quick wizard ...............................................................

8

3.8.2

Space heating/cooling control.....................................

8

3.8.3

Domestic hot water control [A.4] .................................

8

3.8.4

Contact/helpdesk number [6.3.2] ................................

8

4 Energy saving tips

8

5 Maintenance and service

9

5.1

Overview: Maintenance and service..........................................

9

5.2

To find the contact/helpdesk number ........................................

9

6 Troubleshooting

9

6.1

Symptom: You are feeling too cold (hot) in your living room .....

9

6.2

Symptom: The water at the tap is too cold ................................

9

6.3

Symptom: Heat pump failure ..................................................... 10

7 Glossary

10

1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If not, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

Document

Contains…

Format

General
safety
precautions

Safety instructions that you
must read before operating
your system

Paper (in the box of the
indoor unit)

Operation
manual

Quick guide for basic usage

User
reference
guide

Detailed step­by­step
instructions and background
information for basic and
advanced usage

Digital files on 

http://

www.daikineurope.com/
support­and­manuals/
product­information/

.

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

Available screens

Depending on your system layout and installer configuration, not all
screens in this document may be available on your user interface.

Breadcrumbs

1

20.0°C >
18.0°C >
22.0°C >
24.0°C >

7.4.1.1

Room temperature

Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)

Select

Scroll

Breadcrumbs help you to locate where you are in the menu structure
of  the  user  interface.  This  document  also  mentions  these
breadcrumbs.

Example: 

Go  to  [7.4.1.1]: 

  >  User  settings  >  Preset  values  >

Room temperature > Comfort (heating)

2

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Cool  down  a  space  (if  a  heating/cooling  heat  pump  model  is

installed)

▪ Produce domestic hot water (if a DHW tank is installed)

2.1

Components in a typical system
layout

d

a

b

c

e

f

g

B

C

A

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Indoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface at the indoor unit

e

User interface in the living room, used as room thermostat

f

Underfloor heating

g

Heat pump convectors or fan coil units

Summary of Contents for EHBH04CB

Page 1: ...Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHVH04S18CB EHVH08S18CB EHVH08S26CB EHVH11S18CB EHVH11S26CB EHVH16S18CB EHVH16S26CB EHVX0...

Page 2: ...es If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of Documen...

Page 3: ...AVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu structure Sw...

Page 4: ...guide User profile Basic User profile Detailed 15 20 20 0 C Mon Room Actual temperature 15 20 20 0 C 17 30 Actual temperature Room Scheduled Mon Tue To read out the actual and desired room temperatur...

Page 5: ...profile the user interface gives you either a basic or a detailed home page The examples in the illustrations below are in DHW tank mode Scheduled User profile Basic User profile Detailed 15 20 60 C...

Page 6: ...for Monday 1 Use and to select Monday 2 Press to enter the schedule for Monday 3 Program the schedule for Monday Use and to select an entry Use and to change the value of an entry To copy from one da...

Page 7: ...ctuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit Use...

Page 8: ...1 7 Emitter type 1 Slow 3 8 3 Domestic hot water control A 4 Setting Default Fill in Type 2 Scheduled only Maximum setpoint Depends on model INFORMATION There is a risk of space heating cooling capac...

Page 9: ...vent gases into the atmosphere Refrigerant type R410A Global warming potential value 1975 Periodical inspections for refrigerant leaks may be required depending on the applicable legislation Please co...

Page 10: ...g operations will stop and need to be recovered manually The user interface will then ask you to confirm whether the backup heater can take over the heat load or not When the heat pump fails will appe...

Page 11: ......

Page 12: ...4P383117 1 C 0000000 4P383117 1C 2015 01 Copyright 2014 Daikin...

Reviews: