background image

5 Maintenance and service

Operation manual

8

EGSQH10S18AA9W

Daikin Altherma ground source heat pump

4P351750­1 – 2013.06

5

Maintenance and service

5.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.

As end user, you have to:

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

▪ Regularly check if the water pressure indicated on the manometer

is above 1 bar.

Refrigerant

This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol. Do NOT vent gases into the atmosphere.

Refrigerant type: R410A

Global warming potential value: 1975

Periodical  inspections  for  refrigerant  leaks  may  be  required
depending on the applicable legislation. Please contact your installer
for more information.

5.2

To find the contact/helpdesk
number

Go to [6.3.2]: 

 > Information > Error handling > Contact/helpdesk

number.

6

Troubleshooting

6.1

Symptom: You are feeling too cold
(hot) in your living room

Possible cause

Corrective action

The desired room temperature is
too low (high).

Increase (decrease) the desired
room temperature.

If the problem recurs daily, do
one of the following:

▪ Increase  (decrease)  the  room

temperature preset value.

▪ Adjust  the  room  temperature

schedule.

The desired room temperature
cannot be reached.

Increase the desired leaving
water temperature in accordance
with the heat emitter type.

6.2

Symptom: The water at the tap is
too cold

Possible cause

Corrective action

You ran out of domestic hot
water because of unusual high
consumption.

If you immediately need domestic
hot water, activate the DHW tank
booster mode. However, this
consumes extra energy.

If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally.

If the problems recurs daily, do
one of the following:

▪ Increase 

the 

DHW 

tank

temperature preset value.

▪ Adjust 

the 

DHW 

tank

temperature 

schedule.

Example: 

Program 

to

additionally 

heat 

up 

the

DHW  tank  to  a  preset  value
(Storage  eco  =  lower  tank
temperature) during the day.

The desired DHW tank
temperature is too low.

7

Glossary

DHW = Domestic hot water

Hot  water  used,  in  any  type  of  building,  for  domestic
purposes.

LWT = Leaving water temperature

Water temperature at the water outlet of the heat pump.

Summary of Contents for EGSQH10S18AA9W

Page 1: ...Operation manual Daikin Altherma ground source heat pump English Operation manual Daikin Altherma ground source heat pump EGSQH10S18AA9W...

Page 2: ...lled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set T...

Page 3: ...ture e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu stru...

Page 4: ...re To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room 2 Press or to select a preset value or Result The mode will return t...

Page 5: ...ent you cannot change it on the home page 3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode method 1 1 Go to the DHW tank temperature home page Tank 2 Press for more than 5 s...

Page 6: ...User settings 7 Allowed operation mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Away Consumed elec Produced energy Energy metering 6 2 Error history Contact helpdesk number Error...

Page 7: ...aving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too low in cooling mode but ALWAYS according to your actual needs Each saved degree c...

Page 8: ...red room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase decrease the room temperature preset value Adjust the r...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...4P351750 1 0000000J 4P351750 1 2013 06 Copyright 2013 Daikin...