3 Operation

Operation manual

5

EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351750­1 – 2013.06

3.4.3

Sch reheat mode

In sch reheat mode (   ), the domestic hot water control is
the  same  as  in  scheduled  mode.  However,  when  the  DHW  tank
temperature drops below a preset value (=Reheat; example: 45°C),
the  DHW  tank  heats  up  until  it  reaches  this  preset  value.  This
ensures that a minimum amount of hot water is available at all times.

Example: 

t

T

t

60°C

00:00

07:00

50°C

45°C

15°C

40°C

14:00

21:00

1

2

4

3

3.4.4

Using the DHW tank temperature home
page

Typical DHW tank temperature home pages

Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  Depending  on  an  installer  setting,
either  an  actual  temperature  or  a  number  of  people  is  displayed  to
indicate  the  domestic  hot  water  tank  temperature.  The  examples  in
the illustrations below are in DHW tank mode = Scheduled.

User profile = Basic

User profile = Detailed

60°C

1 5 : 2 0

D e s i r e d   t e m p e r a t u r e

Mon

Tank

1 5 : 2 0

0 0 : 0 0

60°C

Storage comfort

Tue

Mon

Ta n k

1 5 : 2 0

4

D e s i r e d   t e m p e r a t u r e

Mon

Tank

4

1 5 : 2 0

0 0 : 0 0

Storage comfort

Tue

Mon

Ta n k

To read out and adjust the desired reheat temperature (in reheat
mode)

1

Go  to  [7.4.3.3]: 

  >  User  settings  >  Preset  values  >  Tank

temperature > Reheat.

Result: 

You  can  read  out  the  desired  reheat  temperature.

2

Press 

  or 

  to  adjust.  Note:  The  reheat  temperature  can

only  be  changed  if  the  DHW  tank  mode  is  scheduled  +  reheat
mode.

To read out and overrule the active or next scheduled desired
temperature (in scheduled mode or sch reheat mode)

1

Go to the DHW tank temperature home page (Tank).

Result: 

 or 

 is displayed.

2

Press 

 or 

 to overrule. Note: If the desired temperature is

weather dependent, you cannot change it on the home page.

3.4.5

Using the DHW tank booster mode

To activate the DHW tank booster mode (method 1)

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 for more than 5 seconds.

To activate the DHW tank booster mode (method 2)

Prerequisite: 

User profile = Detailed

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 to select  .

3.5

Schedules: Example

INFORMATION

The procedures to program other controls are similar.

In this example:

▪ Room temperature schedule in heating mode

▪ Monday = Tuesday = Wednesday = Thursday = Friday

▪ Saturday = Sunday

To program the schedule

1

Go  to  [7.3.1.1]: 

  >  User  settings  >  Set  schedules  >  Room

temp. > Set heating schedule.

2

Select Empty and press 

.

3

Program the schedule for Monday. See below for more details.

4

Copy  from  Monday  to  Tuesday,  Wednesday,  Thursday  and
Friday. See below for more details.

5

Program the schedule for Saturday.

6

Copy from Saturday to Sunday.

7

Save  the  schedule  and  give  it  a  name.  See  below  for  more
details.

To program the schedule for Monday

1

Use 

 and 

 to select Monday.

2

Press 

 to enter the schedule for Monday.

3

Program the schedule for Monday:

▪ Use 

 and 

 to select an entry.

▪ Use 

 and 

 to change the value of an entry.

To copy from one day to another

1

Select  the  day  from  which  you  want  to  copy  and  press 

.

Example: Monday.

2

Select Copy day and press 

.

3

Set the days you want to copy to Yes and press 

. Example:

Tuesday = Yes, Wednesday = Yes, Thursday = Yes and Friday
= Yes.

To save the schedule

1

Press 

, select Save schedule and press 

.

2

Select  User  defined  1,  User  defined  2  or  User  defined  3  and
press 

.

3

Change  the  name  and  press 

.  (Only  applicable  for  room

temperature schedules). Example: MyWeekSchedule

To select which schedule you currently want to use

1

Go to [5]: 

 > Select schedules.

2

Select for which control you want to use a schedule. Example:
[5.1] Room temperature.

3

Select  for  which  operation  mode  you  want  to  use  a  schedule.
Example: [5.1.1] Heating.

4

Select a predefined or user­defined schedule and press 

.

Summary of Contents for EGSQH10S18AA9W

Page 1: ...Operation manual Daikin Altherma ground source heat pump English Operation manual Daikin Altherma ground source heat pump EGSQH10S18AA9W...

Page 2: ...lled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set T...

Page 3: ...ture e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu stru...

Page 4: ...re To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room 2 Press or to select a preset value or Result The mode will return t...

Page 5: ...ent you cannot change it on the home page 3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode method 1 1 Go to the DHW tank temperature home page Tank 2 Press for more than 5 s...

Page 6: ...User settings 7 Allowed operation mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Away Consumed elec Produced energy Energy metering 6 2 Error history Contact helpdesk number Error...

Page 7: ...aving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too low in cooling mode but ALWAYS according to your actual needs Each saved degree c...

Page 8: ...red room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase decrease the room temperature preset value Adjust the r...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...4P351750 1 0000000J 4P351750 1 2013 06 Copyright 2013 Daikin...

Reviews: