background image

3 Operation

Operation manual

4

EGSQH10S18AA9W

Daikin Altherma ground source heat pump

4P351750­1 – 2013.06

Icon

Description

An external heat source is active. Example: Gas
burner.

The disinfection mode is active.

A malfunction occured. Press 

 to display more

information about the malfunction.

Weather­dependent mode is active.

User permission level = Installer.

Defrost/oil return mode is active.

Hot start mode is active.

Emergency operation is active.

3.3

Space heating control

3.3.1

Using the room temperature home page

Typical room temperature home pages

Depending on the user profile, the user interface gives you either a
basic or a detailed home page. To switch between home pages, go
to [7.1.3] User settings > Display > User profile.

User profile = Basic

User profile = Detailed

20.0°C

1 5 : 2 0

A c t u a l   t e m p e r a t u r e

Mon

Room

20.0°C

1 5 : 2 0

1 7 : 3 0

A c t u a l   t e m p e r a t u r e

S c h e d u l e d
Tue

Mon

Room

To read out the actual and desired room temperature

1

Go to the room temperature home page (Room).

Result: 

You  can  read  out  the  actual  temperature. 

Actual temperature

20.0°C

2

Press 

.

Result: 

You  can  read  out  the  desired  temperature. 

Desired temperature

22.0°C

To temporarily overrule the room temperature schedule

1

Go to the room temperature home page (Room).

2

Use 

 or 

 to adjust the temperature.

To change the mode from scheduled to preset value

Prerequisite: 

User profile = Detailed.

1

Go to the room temperature home page (Room).

2

Press 

 or 

 to select a preset value (  or  ).

Result: 

The mode will return to Scheduled according to the overrule

period.

To set the overrule period

1

Go to [7.2]: 

 > User settings > Temperature lock.

2

Select a value and press 

:

▪ Permanent
▪ hours (2, 4, 6, 8)

3.3.2

Using the leaving water temperature
home pages (main + additional)

INFORMATION

The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.
Example: Underfloor heating is designed  for lower leaving
water  temperature  than  radiators  and  heat  pump
convectors  and/or  fan  coil  units.  You  only  have  to  adjust
leaving water temperature settings in case of problems.

For  more  information  about  the  leaving  water  temperature,  see  the
user reference guide.

3.4

Domestic hot water control

3.4.1

Reheat mode

In  reheat  mode  ( ),  the  DHW  tank  continuously  heats  up  to  the
desired temperature (example: 50°C).

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

T

t

▪ T

t

: DHW tank temperature

▪ t: Time

3.4.2

Scheduled mode

In  scheduled  mode  ( ),  the  DHW  tank  produces  hot  water
corresponding  to  a  schedule.  The  best  time  to  allow  the  tank  to
produce hot water is at night, because:

▪ The space heating demand is lower

▪ Electricity tariffs are lower

Example: 

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

5

T

t

▪ T

t

: DHW tank temperature

▪ t: Time

Summary of Contents for EGSQH10S18AA9W

Page 1: ...Operation manual Daikin Altherma ground source heat pump English Operation manual Daikin Altherma ground source heat pump EGSQH10S18AA9W...

Page 2: ...lled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set T...

Page 3: ...ture e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu stru...

Page 4: ...re To change the mode from scheduled to preset value Prerequisite User profile Detailed 1 Go to the room temperature home page Room 2 Press or to select a preset value or Result The mode will return t...

Page 5: ...ent you cannot change it on the home page 3 4 5 Using the DHW tank booster mode To activate the DHW tank booster mode method 1 1 Go to the DHW tank temperature home page Tank 2 Press for more than 5 s...

Page 6: ...User settings 7 Allowed operation mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Away Consumed elec Produced energy Energy metering 6 2 Error history Contact helpdesk number Error...

Page 7: ...aving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too low in cooling mode but ALWAYS according to your actual needs Each saved degree c...

Page 8: ...red room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase decrease the room temperature preset value Adjust the r...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...4P351750 1 0000000J 4P351750 1 2013 06 Copyright 2013 Daikin...

Reviews: