3 Operation
Operation manual
4
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P3517501 – 2013.06
Icon
Description
An external heat source is active. Example: Gas
burner.
The disinfection mode is active.
A malfunction occured. Press
to display more
information about the malfunction.
Weatherdependent mode is active.
User permission level = Installer.
Defrost/oil return mode is active.
Hot start mode is active.
Emergency operation is active.
3.3
Space heating control
3.3.1
Using the room temperature home page
Typical room temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. To switch between home pages, go
to [7.1.3] User settings > Display > User profile.
User profile = Basic
User profile = Detailed
20.0°C
1 5 : 2 0
A c t u a l t e m p e r a t u r e
Mon
Room
20.0°C
1 5 : 2 0
1 7 : 3 0
A c t u a l t e m p e r a t u r e
S c h e d u l e d
Tue
Mon
Room
To read out the actual and desired room temperature
1
Go to the room temperature home page (Room).
Result:
You can read out the actual temperature.
Actual temperature
20.0°C
2
Press
.
Result:
You can read out the desired temperature.
Desired temperature
22.0°C
To temporarily overrule the room temperature schedule
1
Go to the room temperature home page (Room).
2
Use
or
to adjust the temperature.
To change the mode from scheduled to preset value
Prerequisite:
User profile = Detailed.
1
Go to the room temperature home page (Room).
2
Press
or
to select a preset value ( or ).
Result:
The mode will return to Scheduled according to the overrule
period.
To set the overrule period
1
Go to [7.2]:
> User settings > Temperature lock.
2
Select a value and press
:
▪ Permanent
▪ hours (2, 4, 6, 8)
3.3.2
Using the leaving water temperature
home pages (main + additional)
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Example: Underfloor heating is designed for lower leaving
water temperature than radiators and heat pump
convectors and/or fan coil units. You only have to adjust
leaving water temperature settings in case of problems.
For more information about the leaving water temperature, see the
user reference guide.
3.4
Domestic hot water control
3.4.1
Reheat mode
In reheat mode ( ), the DHW tank continuously heats up to the
desired temperature (example: 50°C).
t
60°C
00:00
07:00
50°C
15°C
40°C
14:00
21:00
1
2
3
4
T
t
▪ T
t
: DHW tank temperature
▪ t: Time
3.4.2
Scheduled mode
In scheduled mode ( ), the DHW tank produces hot water
corresponding to a schedule. The best time to allow the tank to
produce hot water is at night, because:
▪ The space heating demand is lower
▪ Electricity tariffs are lower
Example:
t
60°C
00:00
07:00
50°C
15°C
40°C
14:00
21:00
1
2
3
4
5
T
t
▪ T
t
: DHW tank temperature
▪ t: Time