Electric wiring
Be sure to carry out electric wiring in accordance with the terminal wiring diagram (below figure).
Terminal box cover
Screw for tightening cover
(
M4 Cross-Recessed Screw x4
)
[
Tighten torque : 1.0N
・m]
Wiring diagram (EHU25-M(L)07)
As for EHU**-L04 does not equipped with
DIGITAL I/O terminal.
Please consult us if necessary.
12
Danger
・
To protect the electric circuit and prevent electric shock, install the safety device such as a no fuse breaker
or a ground-fault interrupter on the main power source of the hydraulic unit so as to be based on the
European standard (EN60204-1).
(Refer to below table for the capacity of each machine)
・
In order to release the leakage from inverter circuit, ground (earth) terminal must be down to ground over
the third class. (Connect it directly not to pass through the breaker)
・
Wire after installing the machine surely.
・
Be sure to turn off the breaker of the main power source and confirm that the power source was interrupted
before the wiring,
・
Do not connect the supply line to the input and output terminal.
・
Never add the excessive power voltage beyond its specifications of the hydraulic unit
Caution
・
Since this hydraulic unit has protect-over current function built in, thermal for protect-over current function
is not necessary.
・
In case of using thermal, it may work wrong way by the inverter switching.
No fuse breaker
Setup value
EHU14-L04
EHU25-L04
EHU25-L07
EHU25-M07
EHU30-M07
3φ200V 50Hz
15A
15A
15A
15A
15A
3φ200V 60Hz
3φ220V 60Hz
7.3A
7.0A
7.3A
7.9A
7.9A
7.5A
5.7A
5.7A
5.3A
9.1A
9.1A
8.5A
9.6A
9.6A
8.7A
[Rated current in type]
Wiring port
※
This diagram shows power OFF condition
(alarm condition).
[COM
-
ALMa] Normal: closed Abnormal: opened
[COM
-
ALMb] Normal: opened Abnormal: closed
Rated
curr
ent