Introduction
www.DaikinApplied.com
5
CAT 258 • REBEL APPLIED ROOFTOP
Configured Solutions
Rebel Applied provides an adaptive cabinet design that gives
HVAC system designers flexibility to configure solutions
unique to each customer to better serve better solutions for
applications that require greater indoor air quality (IAQ), energy
efficiency, control and redundancy.
Engineered Flexibility
Rebel Applied is designed to provide engineered cabinet
flexibility to give HVAC system designers the flexibility to
minimize footprint, and configure equipment solutions unique
to each customer.
Footprint
Up to 40% shorter and 30% lighter than legacy rooftops, Rebel
Applied is easier to install. Configurable construction in 4”
increments of length lowers replacement costs by eliminating
large transition curbs and simplifying the installation process.
Airflow Flexibility
Rebel Applied makes designing mechanical systems easier by
offering airflow configurations for horizontal supply and return
duct connections
Application Layout
Configure the airflow path to meet building requirements in
healthcare, industrial, education and office applications. Air
path flexibility gives designs flexibility to configure solutions
unique to each customer to better serve applications that
require greater indoor air quality, energy efficiency and
redundancy.
•
Energy Recovery
•
UV lights
•
Extra Access Sections
•
Chilled Water
•
Hot Water/Steam Sections
•
Sound Attenuators
•
Air Blenders
•
Humidifier Grids
•
Final Filtration Sections
•
Fan Array Backdraft Dampers
•
Out of Air Stream Vestibules
Indoor Air Quality
Filtration, temperature, humidity control, and sound are all
important considerations when designing HVAC systems
for indoor air quality. The configurability of Rebel Applied
helps design indoor air quality solutions by providing flexibile
air handling options for filtration, humdification and sound
attenuation.
•
Filtration:
Rebel Applied has flexible filtration options to
satisfy indoor air requirements from varying space types.
—
Pleated Filter Options:
MERV 8 or 13 Filtration
efficiencies in 2" or 4" filters exceed the AHSRAE
62 minimum MERV 6 required to keep the HVAC
equipment clean and operating efficiently.
—
Rigid Cartridge Filters
: 98% of the particulate count
in outside air is less than 0.5 µm. For adequate
filtration of these particles a MERV 13 or higher filter
is required. MERV 14 Cartridge filters are 75-85%
efficient in 0.3-1 µm particle size and offer a longer
filter life than pleated MERV 13 filters. Rebel Applied
is available of MERV 11,14, 16 Filtration in the draw-
through or final position
—
HEPA Filtration:
99.97% efficient particle capture;
these filters are used for life-safety protection in
critical care applications like hospitals and clinics.
—
Carbon or Gas Phase Filtration:
Rebel Applied
can be supplied with other filter media to help
with applications in contaminated ventilation air
environments like air ports or in spaces where odors
may need to be filtered out of the supply air
•
Temperature Control:
Rebel Applied can be configured
for varying levels of temperature and humidity control in
both heating and cooling operating ranging from staged
capacity control to fully modulating capacity control
designed to p/-1°F supply air temperature control.
•
Dehumidification/Humidification:
Indoor humidity control
is a critical component for occupant health. High humidity
supports dust mites and allergies and can result in
material degradation and mold. Low humidity dry’s out
mucous membranes in humans which increased risk of
illness.
•
Acoustics:
Daikin Rebel Applied rooftops offer fan and
air handling configurability to optimize sound for each
application. Perforated Liners and factory mount sound
attenuators provide single source solution to meet space
sound requirements
Direct Replacement
Configurable Cabinetry makes it easy to design your Rebel
Applied rooftop to fit to an existing Trane
®
Intellipak
®
or Daikin
RoofPak
®
curb without requiring expensive adapter curbs or
prolonged downtime during replacement.
Summary of Contents for DPSA