4
www.daikincomfort.com
SS-DM96SN-U
SS-DM96SN-U
www.daikincomfort.com
5
Dimensions
Minimum Clearances to Combustible Materials
Position
Sides
Rear
Front
Bottom
Flue
Top
Upflow
0"
0"
3"
C
0"
1"
Horizontal
6"
0"
3"
C
0"
6"
C = If placed on combustible floor, the floor MUST be wood ONLY.
5
9¼
19
⅝
34½
¾
19½
⅞
¾
B
C
23
2
⅜
1
⅞
2½
2
6½
5
9¼
19
⅝
23
24
⅞
31
⅞
A
21
⅛
2
⅝
14
23
1½
1
⅜
¾
28¾
2
⅜
1
⅞
2½
2
2¾
6½
1
⅞
26½
23½
Folded Flanges
22
Unfolded Flanges
D
Unfolded Flanges
E
Folded Flanges
Air
Discharge
Air
Discharge
LEFT SIDE VIEW
FRONT VIEW
RIGHT SIDE VIEW
Condensate Drain
Trap Exterior
Connection
(Right or Left Side)
¾
PVC
Vent/ Flue Pipe
2" PVC
Alternate
Vent/ Flue
Location
Right-Side
Drain Trap
Exterior Holes
High-Voltage
Electrical Outlet
Alternate
Gas Supply
Low-Voltage
Electrical Outlet
Standard
Gas Supply
Location
Center Dimple
For Alternate
Air Intake Pipe
3"
OD Hole
Air Intake
2" Pipe
Left-Side
Drain Trap
Exterior Holes
High-Voltage
Electrical Outlet
Low-voltage
Electrical Outlet
Air Discharge
Air Return
Model
A
B
C
D
E
DM96SN0403BU
17½"
16"
13⅞"
12⅛"
13⅝"
DM96SN0603BU
17½"
16"
13⅞"
12⅛"
13⅝"
DM96SN0805CU
21"
19½"
17⅜"
16"
17½"