Detailed operation status can be monitored by zone or by group.
The contents of Display on Screen 2 are as shown below.
Obscured indication for
r
-
y
shows the current status
of the zone or group selected.
The example on the left shows the following:
u
includes the following as the maintenance information:
To monitor detailed information on one zone or group
The display on Screen 2 and Screen 3, which is on the following page, is updated
when the screen appears. Once the screen is open, it is not undated before it is
closed and opened again.
The display type for monitoring detailed operation status can
be selected between Icon and List.
Monitoring Detailed Information
Screen 1 Monitoring (Icon)
Screen 2 Operation
[ Group ]
Name
Description
ID
Type
D3 Address
Schedule
Heating Optimization
Heating Mode Optimization
Temperature Limit
Temperature Limit Ctrl
Change Over
Slv R/C
Cool/Heat Option
Ou/Unit Addr
Err Type
Err Code
Err Unit No
Rm Temp
[ Zone ]
Name
Description
ID
Start 1 by 1
Interval
Registered Grp No
Schedule
Slv R/C
Cool/Heat Option
Ou/Unit Addr
Err Type
Err Code
Err Unit No
Rm Temp
: Zone name
: Zone description
: 0 - 63
: Enabled/Disabled
: Interval when Enabled is set for the above
: The number of groups registered for a zone
: Enabled/Disabled
: Mst/Slv (*1)
: With/Without (*2)
: Address of the outdoor unit (*3)
: Normal; Error code when any error is generated (*4)
: 2-digit error code when any error is generated (*4)
: 0 when there is no error
Unit No. when error is generated (*4)
: Inlet temperature of the representative group for a zone (*1)
: Group name
: Group description
: 0 - 63
: Air conditioner or device
: Address between 1-00 and 4-15
: Enable/Disabled
: Enabled/Disabled
: Only displayed during control.
: Enable/Disable
: Only displayed during control.
: Enable/Disable
: Mst/Slv
: With/Without
: Address of the outdoor unit
: Normal; Error code when any error is generated
: 2-digit error code when any error is generated
: 0 when there is no error
Unit No. when error is generated
: Inlet temperature of the indoor unit
On/Off
Operation Mode
Set Point
: Start
: Cool
: 24.0
°
C
For detailed information on a zone, the indication (*1) is Mst
when there is any master R/C is included for air conditioners in
the zone and Slv when all of them are slave R/C. The indication
(*2) is Enabled when any of the air conditioners in the zone has
the Cool/Heat option and Disabled when none of them has the
option. The indication (*3) shows information on the
representative unit for a zone and the error-related indications
(*4) show information on any air conditioner generating an error.
For monitoring further detailed information,
2
1
3
5
4
8
7
9
6
1.
Select Zone or Group from the pull-down menu
w
.
(The example on the left shows Group selected.)
2.
Press the Set/Prop button
e
.
Screen 2 Operation appears.
3.
Press the Advanced Func button
i
.
Screen 3 Advanced Function appears as shown
on the following page.
To go back to Screen 1 Monitoring, press the
Cancel button
o
.
When Zone is selected,
r
-
y
on Screen 2 and
!2
-
!6
on
Screen 3 on the following page show the status of the
representative unit for a zone. For
!0
and
!1
on Screen 3, if
any of the air conditioner of the group in the zone has the filter
or element sign illuminated, Yes/No here is shown in black.