16
PACKAGE GAS SPECIFICATIONS
DCG036-072XXX7BXXXA*
(1)
Units installed in Canada are certifed only to 4500 feet.
(2)
Maximum Overcurrent Protection Device:
MUST
use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
IMPORTANT:
While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in
accordance with the National Electrical Code and/or all local codes.
DCG0360907BXXX
A*
DCG0481157BXXX
A*
DCG0601407BXXX
A*
DCG0721407BXXX
A*
COOLING
COOLING CAPACITY, BTUH
35,000
45,500
58,000
71,000
CAPACITY
SEER/EER
13/11.0
13/11.3
13/11.1
11.0
HEATING
HIGH HEATING INPUT / OUTPUT BTUH
92,000 / 74,000
115,000 / 92,000
138,000 / 110,400
138,000 / 110,400
CAPACITY
LOW HEATING INPUT / OUTPUT BTUH
69,000 / 55,000
86,250 / 69,000
103,000 / 83,000
103,000 / 83,000
A.F.U.E. (%)
80
80
80
80
T EMPERATURE RISE (°F) HI/LOW
40 - 70 / 30 - 60
40 - 70 / 25-55
35 - 65 / 25 - 55
35 - 65 / 25 - 55
UNIT
VOLTAGE (NAMEPLATE)
575/3/60
575/3/60
575/3/60
575/3/60
ELECTRIC AL
UNIT AMPS (TOTAL)
6.7
7.3
8.58
8.58
SPECIFICATION
MINIMUM CIRCUIT AMPACITY
7.7
8
10
10
MAXIMUM OVERCURRENT PROTECTION
(2)
15
15
15
15
HEATING
NUMBER OF BU RNERS
4
5
6
6
SECTION
ORIFICE SIZE NATURAL
43
43
43
43
ORIFICE SIZE LP
55
55
55
55
PRESSURE SWTICH SETTING
0.34
0.34
0.34
0.34
COMPRESSOR
T YPE
SCROLL
SCROLL
SCROLL
SCROLL
RATED LOAD AMPS
3.8
4.4
5.7
5.7
LOCKED ROTOR AMPS
36.5
33
38.9
38.9
CONDENSER
HORSEPOWER
1/4
1/4
1/4
1/4
FAN MOTOR
RPM
1075
1075
1075
1075
RATED LOAD AMPS
0.58
0.58
.58
.58
LOCKED ROTOR AMPS
1.61
1.61
1.61
2.3
BLADE DIAMETER( ") / # OF BLADES
22/4
22/4
22/4
22/4
NOMINAL CFM
3,800
3,800
3,800
3,800
CONDENSER
FACE AREA - SQ. FT.
13
17
12.5
19
COIL
NUMBER OF ROWS
2
1
2
2
FINS PER INCH
16
24
27
27
EVAPORATOR
HORSEPOWER - TYPE
1.5 - STD STATIC BELT
DRIVE
1.5 - STD STATIC BELT
DRIVE
1.5 - STD STATIC BELT
DRIVE
1.5 - STD ST ATIC BELT
DRIVE
BLOWER
NO. OF SPEEDS
1
1
NA
1
MOTOR
RATED LOAD AMPS
2.3
2.3
2.3
2.3
LOCKED ROTOR AMPS
10.9
10.9
11
12
MOTOR SPEED TAP - COOLIN G
---
---
---
---
RPM
1725
1725
1725
1725
EVAPORATOR
DIAMETER X WIDTH (INCHES)
11 X 10
11 X 10
11 X 10
11 X 10
BLOWER
RATED SCFM COOLING
1200
1600
2000
2400
MAX EXTERNAL STATIC PRESS ("w.c.)
0.7
0.8
1.0
1.0
EVAPORATOR
FACE AREA - SQ. FT.
5.4
7.8
7.8
7.8
COIL
NUMBER OF ROWS
3
4
4
4
FINS PER INCH
16
16
16
16
HEATING
PRIMARY LIMIT SETTING (°F)
120
140
220
140
LIMITS
AUXILIARY LIMIT SETTING (°F)
150
150
145
150
ROLLOUT LIMIT SETTING (°F)
350
350
350
350
GENERAL
FILTER SIZE
(1) 24 X 24 x 2
(4) 14 X 20 x 2
(4) 14" X 20" x 2"
(4) 14" X 20" x 2"
INFORMATION
DRAIN SIZE (INCHES)
3/4"
3/4"
3/4"
3/4"
EXPANSION DEVICE
ORIFICE (0.068)
ORIFICE (0.076)
ORIFICE (0.086)
ORIFICE (0.094)
REFRIGERANT CHARGE R-410A (Oz.)
ORIFICE (0.053)
110
100.8
146
POWER SUPPLY CONDUIT HOLE (")
1.125
1.125
1.125
1.125
LOW VOLTAGE CONDUIT HOLE
1/2"
1/2"
1/2"
1/2"
LOW PRESSURE SWITCH (OPEN/CLOSE-PSIG)
22/50
22/50
55/95
55/95
HIGH PRESSURE SWITCH (OPENS-PSIG)
660
660
660
660
SHIPPING WEIGHT LBS.
560
605
645
700
OPERATING WEIGHT LBS.
535
580
620
675
CONDENSER FAN