background image

2 Safety instructions

Installation manual

4

D2CND024A1/4AA + D2TND012~024A4AA

Wall-mounted condensing boiler

3P469346-3E – 2017.07

Pn (80/60)
Pn (50/30)
Qn
D (

Δ

T=30 K)

PMS

PMW

Nox 

kW
kW
kW
l/min

bar
MPa
bar
MPa

/

/

XXXX-XX

PIN: 

a

b

c

d

e

f

g
h

i

j

k

l

m

n

o

p

q

r

s

t

u

v

a

Product number

b

Electrical supply

c

Maximum electrical power consumption

d

Degree of protection

e

Nominal heat output range @ 80/60

f

Nominal heat output range @ 50/30

g

Nominal heat input range

h

Hot water amount @ DT=30

i

NOx class

j

Maximum central heating pressure (bar)

k

Maximum central heating pressure (MPa)

l

Maximum domestic hot water pressure (bar)

m

Maximum domestic hot water pressure (MPa)

n

Country of destination(s)

o

Country of origin

p

Serial number

q

Appliance type

r

Efficiency class

s

Gas category

t

Gas type and supply pressure

u

Product type

v

PIN number

1.3

Symbols on the package

This is a fragile piece of equipment: Please provide a dry
storage space for the unit.

This is a fragile piece of equipment: Please be very careful
not to drop.

Store the unit in a flat position as indicated on the box.

No more than five boxes should be stacked on top of each
other.

2

Safety instructions

These  instructions  are  exclusively  designed  for  qualified  competent
persons.

▪ Work  on  gas  units  must  only  be  carried  out  by  a  qualified  gas

fitter.

▪ Work  on  electrical  equipment  must  only  be  carried  out  by  a

qualified electrician.

▪ The  system  must  be  commissioned  by  a  qualified  competent

person.

WARNING

A  qualified  person  shall  explain  the  operating  principles
and the use of the unit to the user. The user is not allowed
to  perform  any  modifications,  maintenance  or  repairs  on
the  unit,  unless  otherwise  stated,  or  have  the  such
performed  by  unauthorised  third  parties.  Otherwise,  the
unit warranty becomes void.

DANGER

Isolate the boiler from the power mains before working on
it.

WARNING

Unit  installation,  commissioning,  repair,  configuration  and
service must be performed by qualified competent persons
in  accordance  with  local  standards  and  regulations.
Incorrect installation of this unit may harm the user and his/
her  surroundings.  The  manufacturer  is  not  responsible  for
any malfunctions and/or damage that may occur this way.

DANGER

Flammable  fluids  and  materials  must  be  stored  at  least
1 metre away from the boiler.

WARNING

To  ensure  faultless  operation,  long  term  availability  of  all
functions  and  long  working  life  of  the  boiler  only  use
original spares.

3

About the unit

This  Daikin  unit  is  a  wall-mounted  gas-fired  condensing  boiler  that
can  supply  heat  to  central  heating  systems,  as  well  as  supply
domestic hot water. Depending on settings, it is possible to use the
unit  solely  for  hot  water  or  solely  for  central  heating.  Hot  water
supply  type  can  be  instantaneous  or  by  means  of  a  hot  water
storage  tank.  The  type  of  the  boiler  can  be  recognised  from  the
model name written on the identification label. See table below:

Model

Type

Domestic hot water

supply

Filling loop

D2CND024A1AA D2CND024

Instantaneous

Internal

D2CND024A4AA D2CND024

Instantaneous

External

D2TND012A4AA

D2TND012

Storage tank

External

D2TND018A4AA

D2TND018

Storage tank

External

D2TND024A4AA

D2TND024

Storage tank

External

A control unit, which contains a user interface, controls the ignition,
safety systems, and other actuators. User interaction is provided via
that  user  interface,  which  is  composed  of  an  LCD  screen,  push
buttons, and two dials, and which is located on the front cover of the
unit.

3.1

Safety systems

The unit is equipped with several safety systems, to protect it against
dangerous conditions:

Flue  safety  system

:  This  is  controlled  by  the  flue  gas  temperature

sensor  located  on  the  flue  outlet  part  of  the  boiler.  It  is  activated
when the flue gas temperature exceeds safety limits.

Overheating safety system

: This is controlled by the safety limiting

thermostat.  It  is  located  on  the  main  heat  exchanger  and  stops  the
unit  when  the  flow  temperature  reaches  100°C,  to  avoid  boiling  of
the water, which may damage the unit.

Summary of Contents for D2TND012A4AA

Page 1: ...Installation manual Wall mounted condensing boiler English Installation manual Wall mounted condensing boiler D2CND024A1AA D2CND024A4AA D2TND012A4AA D2TND018A4AA D2TND024A4AA...

Page 2: ...tatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra naudojami pagal m s nurodymus tad ja lietoti atbilsto i ra ot ja nor d jumie...

Page 3: ...t be appropriately disposed of in accordance with local and national regulations The components are easy to separate and the plastics are marked This allows the various components to be sorted for app...

Page 4: ...nfiguration and service must be performed by qualified competent persons in accordance with local standards and regulations Incorrect installation of this unit may harm the user and his her surroundin...

Page 5: ...rature sensor which is located at the outlet of the main heat exchanger This protection activates the boiler pump when the water temperature drops below 13 C and it activates the burner when the water...

Page 6: ...Return temperature sensor s Silencer t Automatic air vent pump u Water pressure sensor v By pass w Boiler pump x Domestic hot water flow sensor y Domestic hot water flow limiter z Internal filling val...

Page 7: ...max m h 0 12 0 46 0 12 0 69 0 12 0 96 0 12 0 96 Combustion products mass flow rate min max G20 g s 1 32 5 12 1 32 7 78 1 32 10 75 1 32 10 75 Combustion products mass flow rate min max G31 g s 1 23 4...

Page 8: ...aters 50 C return temperature at heater inlet 4 Installation 4 1 To open the unit WARNING Only qualified competent persons are allowed to open the unit Certain actions explained in this document such...

Page 9: ...o the current I E E Wiring Regulations local Building Regulations or any other local regulations currently in service The intake air must not include chemicals that may cause corrosion toxic gas forma...

Page 10: ...ight and related system charge pressure are given below h p 6 m 0 8 bar 7 m 0 9 bar 8 m 1 0 bar 9 m 1 1 bar 10 m 1 2 bar 11 m 1 3 bar 12 m 1 4 bar 13 m 1 5 bar h h System water height m p System charg...

Page 11: ...f the user 4 7 Residual pump lift graph The residual pump lift graph shows the amount of pump lift mbar that remains for the central heating circuit 0 0 100 200 300 400 500 600 700 800 200 400 600 800...

Page 12: ...age while the gas line to the boiler is open see 5 3 To check for gas leakage on page 25 In case gas piping is adjacent to the wall and is to be connected to the gas pipe connection of the boiler with...

Page 13: ...any damage that may occur this way WARNING Use a dedicated power circuit Never use a power supply cable shared by another unit The unit runs on 230 V AC 50 Hz power A power cable is delivered with the...

Page 14: ...ands that are sent with the unit must be assembled to the bottom sheet of the boiler in case connection of these options Below you can see the cable glands placement PG 9 PG 9 PG 7 PG 7 Holes on the b...

Page 15: ...4AA Wall mounted condensing boiler 3P469346 3E 2017 07 4 8 6 Wiring diagram DANGER RISK OF ELECTROCUTION Disconnect the power supply for more than 10 minutes before servicing Models D2CND024A1AA and D...

Page 16: ...face Ext3 X1M Opentherm room thermostat Ext4 X2M External power output 230 V AC Ext5 X2M Reserved not in use X1M X4 X11 X12 Low voltage terminal strip X2M X1 X2 High voltage terminal strip 4 8 7 Guide...

Page 17: ...e that products of combustion discharging from the terminal cannot re enter the building or other buildings through ventilators windows doors other sources of natural air infiltration or forced ventil...

Page 18: ...kit Optional c 45 elbow 60 100 d Extension 60 100 mm e Flat roof outlet kit f 90 elbow 60 100 g 45 elbow 60 100 h 30 elbow 60 100 i Extension 60 100 L 500 1000 mm Allowable flue length for C33x D2TND...

Page 19: ...and lengths of the flue system For D2TND Nominal combustion products temperature 77 C Combustion products mass flow rate 10 75 g s Overheat combustion products temperature 90 C Minimum combustion pro...

Page 20: ...use flue outlet duct length must be shortened with the same length Type C83x twin pipes flue system The boiler draws combustion air from outside via a separate supply pipe routed through the external...

Page 21: ...gh 140 19 6 69 2 DN 80 Flex square and rough 130 17 0 60 0 DN 80 Flex square and rough 120 12 2 43 0 DN 80 Star square and rough 140 47 5 167 8 DN 80 Star square and rough 120 33 3 117 9 Allowable flu...

Page 22: ...Tee 60 100 with measurement point EKFGP4667 90 elbow 60 100 with measurement point DRMEEA60100BA 90 elbow 60 100 EKFGP4660 90 elbow 80 125 EKFGP4810 45 elbow 60 100 EKFGP4661 45 elbow 80 125 EKFGP4811...

Page 23: ...venting 10 If after the venting the pressure decreases below 0 8 bar refill with water until the pressure reaches 0 8 bar again 11 Isolate the appliance from power mains Method 2 For model D2CND024A4A...

Page 24: ...onvert the system for use with a different type of gas 1 Open the front cover of the unit as described in this manual 2 To set natural gas adjust screw on the gas valve to position 1 3 To set LPG adju...

Page 25: ...nit to the main power supply The user interface will be energised 5 4 1 To commission the central heating 1 Set mode to winter mode via Mode button on the user interface and icons are displayed on the...

Page 26: ...5 Check that domestic hot water temperature rise is around 34 C 6 Hand over to the user After completing the installation and commissioning of the system the installer should hand over to the househo...

Page 27: ......

Page 28: ...MA S STEMLER SAN T C A K kbakkalk y Mah Kay da Cad No 1 Kat 21 22 34750 Ata ehir STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr 3P469346 3E 2017 07...

Reviews: