background image

4 Operation

Operation manual

8

FTXM20~71N2V1B

Daikin room air conditioner

3P485919-8K – 2018.09

2

Press 

 or 

 to change the time setting.

3

Press 

 again.

Result: 

  and  the  set  time  are  displayed  on  the  LCD.  The  timer

lamp lights up.

INFORMATION

Each  time 

  or 

  is  pressed,  the  time  setting

advances  by  10  minutes.  Holding  the  button  down  will
change the setting rapidly.

4

To stop operation, press 

.

Result: 

 and 

 disappear from the LCD and the timer

lamp goes off.   and the day of the week are displayed on the
LCD.

4.9.3

To combine OFF timer and ON timer

1

To  set  the  timers,  refer  to 

"4.9.1  To  start/stop  OFF  timer

operation"  on  page  7

  and 

"4.9.2  To  start/stop  ON  timer

operation" on page 7

.

Result: 

 and 

 are displayed on the LCD.

Example:

Display

Current time

Set while…

Operation

6:00

the unit is
operating.

Stops at 7:00
and starts at
14:00.

the unit is NOT
operating.

Starts at 14:00.

Note: 

 If the timer setting is active, the current time is NOT displayed

on the LCD.

4.10

Weekly timer operation

With this operation, you can save up to 4 timer settings for each day
of the week.

Example: 

Create  a  different  setting  from  Monday  to  Friday  and  a

different setting for weekends.

Day of the week

Setting example

Monday

▪ Make up to 4 settings.

6:00

8:30

17:30

25°C

27°C

22:00

1

2

3

4

ON

OFF

ON

OFF

Tuesday~Friday

▪ Use the copy mode if the

settings are the same as
for Monday.

6:00

8:30

17:30

25°C

27°C

22:00

1

2

3

4

ON

OFF

ON

OFF

Saturday

▪ No timer setting

Sunday

▪ Make up to 4 settings.

8:00 10:00

19:00 21:00

27°C

27°C

25°C

ON

OFF

OFF

ON

1

2

3

4

ON-ON-ON-ON  setting.

  Enables  scheduling  the  operation  mode

and set temperature.

OFF-OFF-OFF-OFF  setting.

Only  the  turn  off  time  can  be  set  for

each day.

Note: 

 Be sure to aim the user interface at the indoor unit and check

for a receiving tone when setting the Weekly timer operation.

INFORMATION

The  clock  MUST  be  set  correctly  before  using  any  timer
functions. Refer to 

"3.3 To set the clock" on page 4

.

INFORMATION

▪ Weekly timer and ON/OFF timer operation CANNOT be

used  at  the  same  time.  The  ON/OFF  timer  operation
takes priority. Weekly timer will be in standby, 
disappears  from  the  LCD.  When  the  ON/OFF  timer  is
completed, the Weekly timer becomes active.

▪ The  day  of  the  week,  ON/OFF  timer  mode,  time  and

temperature  (only  for  ON  timer)  can  be  set  with  the
Weekly timer. Other settings are based on previous ON
timer setting.

4.10.1

To set Weekly timer operation

1

Press 

.

Result: 

The day of the week and the reservation number of the

current day are displayed.

2

Press 

  or 

  to  select  the  day  of  the  week  and  the

reservation number.

3

Press 

.

Result: 

The day of the week is set. 

 and 

 blink.

4

Press 

 or 

 to select the mode.

Result: 

The setting will change as follows:

Display

Feature

ON timer

OFF timer

Blank

Deletes reservation

5

Press 

.

Result: 

The ON/OFF timer mode is set. 

 and the time

blink.

Note: 

Press 

  to  return  to  the  previous  screen.  If  blank  is

selected, continue to step 9.

6

Press 

  or 

  to  select  the  time.  The  time  can  be  set

between 0:00~23:50 in 10-minute intervals.

7

Press 

.

Result: 

The  time  is  set  and 

  and  the  temperature

blink.

Note: 

Press 

 to return to the previous screen. If OFF timer

is selected, continue to step 9.

Summary of Contents for CTXM15N2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner CTXM15N2V1B FTXM20N2V1B FTXM25N2V1B FTXM35N2V1B FTXM42N2V1B FTXM50N2V1B FTXM60N2V1B FTXM71N2V1B...

Page 2: ...11 1 Precautions when using the wireless adapter 10 4 11 2 To install the Daikin Online Controller application 10 5 Energy saving and optimum operation 10 6 Maintenance and service 10 6 1 Overview Ma...

Page 3: ...interface Direct sunlight Do NOT expose the user interface to direct sunlight Dust Dust on the signal transmitter or receiver will reduce sensitivity Wipe off dust with a soft cloth Fluorescent light...

Page 4: ...reference position 4 Operation 4 1 Operation range Use the system in the following temperature and humidity ranges for safe and effective operation In combination with outdoor unit RZAG Cooling and d...

Page 5: ...0 30 C 18 30 C Note When using drying or fan only mode you cannot adjust the temperature 4 Press to stop operation Result disappears from the LCD The operation lamp goes off 4 3 Airflow rate 1 Press t...

Page 6: ...to malfunction Do NOT place large objects near the Intelligent eye sensor INFORMATION Powerful or Night set operation CANNOT be used at the same time with Intelligent eye operation The last selected...

Page 7: ...erated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharge may stop temporarily to prevent ozone...

Page 8: ...8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operation mode and set temperature OFF OFF OFF OFF setting Only the turn off time can be set for...

Page 9: ...n confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservat...

Page 10: ...owing precautions to ensure the system operates properly Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds Ventilate often Extended use requires special...

Page 11: ...the unit with wet hands Do NOT place any objects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAU...

Page 12: ...r filters in the shade It is recommended to clean the air filters every 2 weeks 6 7 To clean the titanium apatite deodorizing filter INFORMATION Clean the filter with water every 6 months 1 Remove the...

Page 13: ...power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electric shock or fire Contact your dealer The system MUST be repaired by a qua...

Page 14: ......

Page 15: ......

Page 16: ...3P485919 8K 2018 09 Copyright 2018 Daikin...

Reviews: