background image

4 Operation

Operation manual

5

FTXM20~71N2V1B
Daikin room air conditioner
3P485919-8K – 2018.09

Setting

Description

 Automatic

The system cools down or heats up a
room to the temperature setpoint. It
automatically switches between cooling
and heating if necessary.

 Drying

The system decreases the humidity in a
room without changing the temperature.

 Heating

The system heats up a room to the
temperature setpoint.

 Cooling

The system cools down a room to the
temperature setpoint.

 Fan

The system only controls the airflow
(airflow rate and airflow direction).

The system does NOT control the
temperature.

Additional info:

Outside  temperature.

  The  system's  cooling  or  heating  effect

decreases when the outside temperature is too high or too low.

Defrost operation.

 During heating operation, frost might occur on

the  outdoor  unit  and  decrease  the  heating  capacity.  In  that  case,
the  system  automatically  switches  to  defrosting  operation  to
remove  the  frost.  During  defrosting  operation,  hot  air  is  NOT
blown from the indoor unit.

Humidity  sensor.

  Control  the  humidity  by  decreasing  the

humidity during cooling process.

4.2.1

To start/stop operation and to set the
temperature

: Unit is operating.

: Operation mode = Automatic

: Operation mode = Drying

: Operation mode = Cooling

: Operation mode = Heating

: Operation mode = Fan only

: Shows the set temperature.

1

Press 

 one or more times to select the operation mode.

Result: 

The mode will be set as follows:

2

Press 

 to 

start

 operation.

Result: 

 and the selected mode are displayed on the LCD.

3

Press 

  or 

  one  or  more  times  to  lower  or  raise  the

temperature

.

Cooling
operation

Heating
operation

Automatic
operation

Drying or Fan
only operation

18~32°C

10~30°C

18~30°C

Note:

 When using 

drying

 or 

fan

 

only

 mode, you cannot adjust the

temperature.

4

Press 

 to 

stop

 operation.

Result: 

  disappears  from  the  LCD.  The  operation  lamp  goes

off.

4.3

Airflow rate

1

Press 

 to choose:

5 airflow rate levels, from "

" to "

"

Automatic operation

Indoor unit quiet operation. When the airflow is set to

"

", the noise from the unit will be reduced.

INFORMATION

▪ If  the  unit  reach  the  temperature  setpoint  in  cooling,

heating or automatic mode. Fan will stop operating.

▪ When  using  drying  operation  mode,  you  CANNOT

adjust the airflow rate setting.

4.3.1

To adjust the airflow rate

1

Press 

 to change the airflow setting as follows:

4.4

Airflow direction

When.

 Adjust the airflow direction as desired.

What.

  The  system  directs  the  airflow  differently,  depending  on  the

user  selection  (swinging  or  fixed  position).  It  does  so  by  moving
horizontal blades (flaps) or vertical blades (louvers).

Setting

Airflow direction

 Vertical automatic

swing

Moves up and down.

 Horizontal

automatic swing

Moves from side to side.

+

 3-D airflow

direction

Moves simultaneously up and down and
from side to side

[—]

Stays in a fixed position.

CAUTION

▪ ALWAYS use a user interface to adjust the position of

the  flaps  and  louvers.  When  the  flaps  and  louvers  are
swinging  and  you  move  them  forcibly  by  hand,  the
mechanism will break.

The  movable  range  of  the  flap  varies  according  to  the  operation
mode. The flap will stop at the upper position when the airflow rate is
changed to low during the up and down swing setting.

4.4.1

To adjust vertical airflow direction

1

Press 

.

Result: 

  appears  on  the  LCD.  The  flaps  (horizontal  blades)

will begin to swing.

2

To  use  fixed  position,  press 

  when  the  flaps  reach  the

desired position.

Result: 

  disappears  from  the  LCD.  The  flaps  will  stop

moving.

4.4.2

To adjust horizontal airflow direction

1

Press 

.

Result: 

  appears  on  the  LCD.  The  louvers  (vertical

blades) will begin to swing.

Summary of Contents for CTXM15N2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner CTXM15N2V1B FTXM20N2V1B FTXM25N2V1B FTXM35N2V1B FTXM42N2V1B FTXM50N2V1B FTXM60N2V1B FTXM71N2V1B...

Page 2: ...11 1 Precautions when using the wireless adapter 10 4 11 2 To install the Daikin Online Controller application 10 5 Energy saving and optimum operation 10 6 Maintenance and service 10 6 1 Overview Ma...

Page 3: ...interface Direct sunlight Do NOT expose the user interface to direct sunlight Dust Dust on the signal transmitter or receiver will reduce sensitivity Wipe off dust with a soft cloth Fluorescent light...

Page 4: ...reference position 4 Operation 4 1 Operation range Use the system in the following temperature and humidity ranges for safe and effective operation In combination with outdoor unit RZAG Cooling and d...

Page 5: ...0 30 C 18 30 C Note When using drying or fan only mode you cannot adjust the temperature 4 Press to stop operation Result disappears from the LCD The operation lamp goes off 4 3 Airflow rate 1 Press t...

Page 6: ...to malfunction Do NOT place large objects near the Intelligent eye sensor INFORMATION Powerful or Night set operation CANNOT be used at the same time with Intelligent eye operation The last selected...

Page 7: ...erated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharge may stop temporarily to prevent ozone...

Page 8: ...8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operation mode and set temperature OFF OFF OFF OFF setting Only the turn off time can be set for...

Page 9: ...n confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservat...

Page 10: ...owing precautions to ensure the system operates properly Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds Ventilate often Extended use requires special...

Page 11: ...the unit with wet hands Do NOT place any objects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAU...

Page 12: ...r filters in the shade It is recommended to clean the air filters every 2 weeks 6 7 To clean the titanium apatite deodorizing filter INFORMATION Clean the filter with water every 6 months 1 Remove the...

Page 13: ...power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electric shock or fire Contact your dealer The system MUST be repaired by a qua...

Page 14: ......

Page 15: ......

Page 16: ...3P485919 8K 2018 09 Copyright 2018 Daikin...

Reviews: