background image

4 Operation

Operation manual

7

FTXM20~71N2V1B
Daikin room air conditioner
3P485919-8K – 2018.09

INFORMATION

▪ Powerful and Econo operation CANNOT be used at the

same time. The last selected function takes priority.

▪ Econo  operation  reduces  power  consumption  of  the

outdoor  unit  by  limiting  the  rotation  speed  of  the
compressor.  If  power  consumption  is  already  low,
Econo  operation  will  NOT  further  reduce  power
consumption.

4.7.2

Outdoor unit quiet operation

Use  Outdoor  unit  quiet  operation  when  you  want  to  decrease  the
noise level of the outdoor unit. 

Example: 

At night.

INFORMATION

▪ Powerful and Outdoor unit quiet operation CANNOT be

used at the same time. The last selected function takes
priority.

▪ This  function  is  only  available  in  Automatic,  Cooling,

and Heating operation.

▪ Outdoor unit quiet operation limits the rotation speed of

the compressor. If the rotation speed of compressor is
already  low,  Outdoor  unit  quit  operation  will  NOT
further reduce the compressor rotation speed.

4.7.3

To start/stop Econo and Outdoor unit
quiet operation

1

Press 

 one or more times.

Result: 

The setting will change as follows.

Display

Operation

Econo

Outdoor unit quiet

+

Econo and Outdoor unit quiet

Both deactivated

2

To  stop  operation,  press 

  until  both  symbols  disappear

from the LCD.

Note: 

Econo  operation  can  be  only  set  when  the  unit  is  running.

Pressing 

 cancels the setting and 

 disappears from the LCD.

Note: 

  remains  on  the  LCD,  even  if  you  turn  off  the  unit  using

the user interface or indoor unit ON/OFF switch.

4.8

Flash streamer air cleaning
operation

Streamer  generates  a  high-speed  electron  stream  with  a  high
oxidizing power, reducing bad odours and viruses. Together with the
titanium  apatite  deodorizing  filter  and  the  air  filters,  this  function
cleans the air in the room.

INFORMATION

▪ The  high-speed  electrons  are  generated  and  go  away

inside the unit to ensure safe operation.

▪ The Streamer discharge may generate a fizzing sound.

▪ If  the  airflow  becomes  weak,  the  Streamer  discharge

may stop temporarily to prevent ozone smell.

4.8.1

To start/stop Flash Streamer operation

1

Press 

.

Result: 

 is displayed on the LCD and the air in the room is

cleaned.

2

To stop operation, press 

.

Result: 

 disappears from the LCD and operation stops.

4.9

OFF/ON timer operation

Timer  functions  are  useful  for  automatically  switching  the  air
conditioner on/off at night or in the morning. You can also use OFF
timer and ON timer in combination.

INFORMATION

Program the timer again in case of:

▪ A breaker has turned the unit off.

▪ A power failure.

▪ After replacing batteries in the user interface.

INFORMATION

The  clock  MUST  be  set  correctly  before  using  any  timer
functions. Refer to 

"3.3 To set the clock" on page 4

.

4.9.1

To start/stop OFF timer operation

1

Press 

 to start.

Result: 

 is displayed on the LCD, the timer lamp lights

up,  and 

  blinks.    and  the  day  of  the  week  disappear  from

the LCD.

2

Press 

 or 

 to change the time setting.

3

Press 

 again.

Result: 

 and the set time are displayed on the LCD.

Result: 

The timer lamp lights up.

INFORMATION

Each  time 

  or 

  is  pressed,  the  time  setting

advances  by  10  minutes.  Holding  the  button  down  will
change the setting rapidly.

4

To stop operation, press 

.

Result: 

  and 

  disappear  from  the  LCD  and  the  timer

lamp goes off.   and the day of the week are displayed on the LCD.

INFORMATION

When you set the ON/OFF timer, the time setting is stored
in  the  memory.  The  memory  will  be  reset  when  the  user
interface batteries are replaced.

Use of night set mode in combination with OFF timer

The  air  conditioner  automatically  adjusts  the  temperature
setting  (0.5°C  up  in  cooling,  2.0°C  down  in  heating)  to
prevent 

excessive 

cooling/heating 

and 

ensure 

a

comfortable sleeping temperature.

4.9.2

To start/stop ON timer operation

1

Press 

 to start.

Result: 

 is displayed on the LCD, the timer lamp lights

up,  and 

  blinks.    and  the  day  of  the  week  disappear  from

the LCD.

Summary of Contents for CTXM15N2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner CTXM15N2V1B FTXM20N2V1B FTXM25N2V1B FTXM35N2V1B FTXM42N2V1B FTXM50N2V1B FTXM60N2V1B FTXM71N2V1B...

Page 2: ...11 1 Precautions when using the wireless adapter 10 4 11 2 To install the Daikin Online Controller application 10 5 Energy saving and optimum operation 10 6 Maintenance and service 10 6 1 Overview Ma...

Page 3: ...interface Direct sunlight Do NOT expose the user interface to direct sunlight Dust Dust on the signal transmitter or receiver will reduce sensitivity Wipe off dust with a soft cloth Fluorescent light...

Page 4: ...reference position 4 Operation 4 1 Operation range Use the system in the following temperature and humidity ranges for safe and effective operation In combination with outdoor unit RZAG Cooling and d...

Page 5: ...0 30 C 18 30 C Note When using drying or fan only mode you cannot adjust the temperature 4 Press to stop operation Result disappears from the LCD The operation lamp goes off 4 3 Airflow rate 1 Press t...

Page 6: ...to malfunction Do NOT place large objects near the Intelligent eye sensor INFORMATION Powerful or Night set operation CANNOT be used at the same time with Intelligent eye operation The last selected...

Page 7: ...erated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharge may stop temporarily to prevent ozone...

Page 8: ...8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operation mode and set temperature OFF OFF OFF OFF setting Only the turn off time can be set for...

Page 9: ...n confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservat...

Page 10: ...owing precautions to ensure the system operates properly Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds Ventilate often Extended use requires special...

Page 11: ...the unit with wet hands Do NOT place any objects containing water on the unit CAUTION After a long use check the unit stand and fitting for damage If damaged the unit may fall and result in injury CAU...

Page 12: ...r filters in the shade It is recommended to clean the air filters every 2 weeks 6 7 To clean the titanium apatite deodorizing filter INFORMATION Clean the filter with water every 6 months 1 Remove the...

Page 13: ...power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electric shock or fire Contact your dealer The system MUST be repaired by a qua...

Page 14: ......

Page 15: ......

Page 16: ...3P485919 8K 2018 09 Copyright 2018 Daikin...