Daikin CTXJ25TVMAW Operation Manual Download Page 11

To start/stop Comfort and Intelligent eye operation

1. 

Press 

 one or more times. 

Result:

 The setting will change as follows:

Display

Operation

Comfort airflow

Intelligent eye

 +

 

Comfort airflow and Intelligent eye

Both deactivated

Note:

 If there are people close to the front of the indoor unit or 

there are too many people, use both operations at the same time.

2. 

To stop operation, press 

 until both symbols 

disappear from the LCD.

4-3-5 

Powerful operation

This operation quickly maximises the cooling/heating effect in 
any operation mode. You can get the maximum capacity.

 INFORMATION

Powerful operation CANNOT be used together with Econo, 

Comfort airflow, Intelligent eye and Outdoor unit quiet

 

operation. The last selected function takes priority.

Powerful operation will NOT increase the capacity of the unit 
if it already operates at maximum capacity.

To start/stop Powerful operation

1. 

Press 

 to start.

Result:

 

 is displayed on the LCD. Powerful operation runs 

for 20 minutes; after that, operation returns to the previously set 
mode.

Mode

Airflow rate

Cooling/Heating/
Automatic

• 

To maximise the cooling/heating effect, 
the capacity of outdoor unit is increased.

• 

The airflow rate is fixed to the maximum 

setting and CANNOT be changed.

The temperature can be set only in 
Automatic mode.

Drying

• 

The temperature setting is lowered by 2.5°C.

• 

The airflow rate is slightly increased.

Fan only

The airflow rate is fixed to the maximum setting.

2. 

Press 

 to stop. 

Result:

 

 disappears from the LCD.

Note:

 Powerful operation can only be set when the unit is 

running.

Press 

 to cancel this mode; 

 disappears from the LCD.

4-3-6  Econo and Outdoor unit quiet operation

Econo operation

This is a function which enables efficient operation by limiting 

the maximum power consumption value. This function is useful 
for cases in which attention should be paid to ensure a circuit 
breaker will not trip when the product runs alongside other 
appliances.

 INFORMATION

• 

Powerful and Econo operation CANNOT be used at the 
same time. The last selected function takes priority.

• 

Econo operation reduces power consumption of the outdoor 
unit by limiting the rotation speed of the compressor. If power 
consumption is already low, Econo operation will NOT further 
reduce power consumption.

Outdoor unit quiet operation

Use Outdoor unit quiet operation when you want to decrease 
the noise level of the outdoor unit. 

Example

: At night.

 INFORMATION

• 

Powerful and Outdoor unit quiet operation CANNOT be used 
at the same time. The last selected function takes priority.

• 

This function is only available in Automatic, Cooling, and 
Heating operation.

• 

Outdoor unit quiet operation limits the rotation speed of the 
compressor. If the rotation speed of compressor is already 
low, Outdoor unit quiet operation will NOT further reduce the 
compressor rotation speed.

To start/stop Econo and Outdoor unit quiet operation

1. 

Press 

 one or more times. 

Result:

 The setting will change as follows.

Display

Operation

Econo

Outdoor unit quiet

 

Econo and Outdoor unit quiet

Both deactivated

2. 

To stop operation, press 

 until both symbols 

disappear from the LCD.

Note:

 Econo operation can be only set when the unit is running.

Pressing 

 cancels the setting and 

 disappears from the LCD.

Note:

 

 remains on the LCD, even if you turn off the unit 

using the remote controller or indoor unit ON/OFF switch.

• 

If using a multi system, the OUTDOOR UNIT QUIET 
operation will work only when this function is set on all 
operated indoor units. However, if using priority room setting, 

refer to “

Note for Multi System

” on page 16.

 10

01_EN_3P620957-1.indd   10

26-Jun-20   10:17:32 AM

Summary of Contents for CTXJ25TVMAW

Page 1: ...r round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS CTXJ25TVMAW CTXJ35TVMAW CTXJ50TVMAW CTXJ60TVMAW CTXJ25TVMAK CTXJ35TVMAK CTXJ50TVMA...

Page 2: ...QUIET operation 17 6 1 4 COOL HEAT mode lock 17 6 1 5 Priority room setting Not available on some models 17 7 Maintenance and service 17 7 1 Overview Maintenance and service 17 7 2 To clean the indoor...

Page 3: ...us gas Do not use the air conditioner until a qualified service person confirms that the leakage has been repaired Do not attempt to install or repair the air conditioner yourself Improper workmanship...

Page 4: ...n adverse influence on the performance product quality and life of the air conditioner This appliance is not intended to be used by persons with reduced physical sensory or mental capabilities or with...

Page 5: ...h2sec d a g m h c b n l f e i j k p o a Signal transmitter b LCD display c Temperature adjustment button d ON OFF button e Vertical swing button and menu push 2 seconds f Horizontal swing button g Com...

Page 6: ...s with tap water and seek the attention of a medical professional Keep batteries out of reach of children In the event that batteries are swallowed seek the immediate attention of a medical profession...

Page 7: ...selected setting press Result The brightness setting is changed Note The display automatically returns to the default screen after 60 seconds To return to the default screen sooner press twice 3 5 To...

Page 8: ...y is in the room Powerful To cool down or heat up the room quickly Feature Tasks ON timer OFF timer To automatically turn ON or OFF the system Weekly timer To automatically turn ON or OFF the system o...

Page 9: ...side to side Stays in a fixed position CAUTION ALWAYS use a remote controller to adjust the position of the flaps and louvres When the flaps and louvres are swinging and you move them forcibly by han...

Page 10: ...selected function takes priority If the Vertical automatic swing is selected Comfort airflow operation will be cancelled To turn ON OFFVertical airflow function 1 Press for at least 2 seconds Result T...

Page 11: ...efficient operation by limiting the maximum power consumption value This function is useful for cases in which attention should be paid to ensure a circuit breaker will not trip when the product runs...

Page 12: ...use OFF timer and ON timer in combination INFORMATION Programme the timer again in case of A circuit breaker has turned the unit off A power failure After replacing batteries in the remote controller...

Page 13: ...remote controller at the indoor unit and check for a receiving tone when setting the Weekly timer operation See 2 2 3 To operate the remote controller on page 5 INFORMATION The clock MUST be set corre...

Page 14: ...ll reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week and reservation number to...

Page 15: ...bile Controller application 1 Open Google Play for appliances using Android App Store for appliances using iOS 2 Search for Daikin Mobile Controller 3 Follow the directions on the screen to install 4...

Page 16: ...smartphone to the home network To reset the connection setting to the factory default Reset the connection setting to the factory default in case you want to switch between the WPS and the AP connect...

Page 17: ...the room temperature properly for a comfortable environment Avoid excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using th...

Page 18: ...e of the priority room takes precedence you can select a different operation mode from other rooms Example Room A is the priority room in this example When COOL operation is selected in room A while o...

Page 19: ...ELECTROCUTION Before cleaning be sure to stop the operation turn the circuit breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean with a soft cloth If it i...

Page 20: ...FORMATION Clean the filter with water every 6 months 1 Remove the dust from the filter with a vacuum cleaner INFORMATION Replace the filter every 3 years Dispose of the old filter as non flammable was...

Page 21: ...RMATION It is recommended to have periodical maintenance performed by a specialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the user In certain operating cond...

Page 22: ...to set the temperature on page 7 Check if the airflow direction setting is appropriate Refer to 4 3 3 Airflow direction on page 8 Check if the air inlet or outlet of the outdoor or indoor unit is NOT...

Page 23: ...possible to fix the problem yourself contact your installer and state the symptoms the complete model name of the unit with manufacturing number if possible and the installation date possibly listed o...

Page 24: ...ription Indoor unit PCB abnormality Freeze up protection or high pressure control Fan motor DC motor abnormality Streamer unit error Indoor heat exchanger thermistor abnormality Opening or closing fro...

Page 25: ...wireless adapter connection status on page 14 Try to resetting to the factory default and repeat the setting See To reset the connection setting to the factory default on page 15 9 Disposal NOTICE Do...

Page 26: ...MEMO 25 01_EN_3P620957 1 indd 25 26 Jun 20 10 17 50 AM...

Page 27: ...01_EN_3P620957 1 indd 26 26 Jun 20 10 17 50 AM...

Page 28: ...3P620957 1 M20N052 2006 HT The two dimensional bar code is a manufacturing code 00_CV_3P620957 1 indd 2 23 Jun 20 11 21 05 AM...