To start/stop Comfort and Intelligent eye operation
1.
Press
one or more times.
Result:
The setting will change as follows:
Display
Operation
Comfort airflow
Intelligent eye
+
Comfort airflow and Intelligent eye
—
Both deactivated
Note:
If there are people close to the front of the indoor unit or
there are too many people, use both operations at the same time.
2.
To stop operation, press
until both symbols
disappear from the LCD.
4-3-5
Powerful operation
This operation quickly maximises the cooling/heating effect in
any operation mode. You can get the maximum capacity.
INFORMATION
Powerful operation CANNOT be used together with Econo,
Comfort airflow, Intelligent eye and Outdoor unit quiet
operation. The last selected function takes priority.
Powerful operation will NOT increase the capacity of the unit
if it already operates at maximum capacity.
To start/stop Powerful operation
1.
Press
to start.
Result:
is displayed on the LCD. Powerful operation runs
for 20 minutes; after that, operation returns to the previously set
mode.
Mode
Airflow rate
Cooling/Heating/
Automatic
•
To maximise the cooling/heating effect,
the capacity of outdoor unit is increased.
•
The airflow rate is fixed to the maximum
setting and CANNOT be changed.
The temperature can be set only in
Automatic mode.
Drying
•
The temperature setting is lowered by 2.5°C.
•
The airflow rate is slightly increased.
Fan only
The airflow rate is fixed to the maximum setting.
2.
Press
to stop.
Result:
disappears from the LCD.
Note:
Powerful operation can only be set when the unit is
running.
Press
to cancel this mode;
disappears from the LCD.
4-3-6 Econo and Outdoor unit quiet operation
Econo operation
This is a function which enables efficient operation by limiting
the maximum power consumption value. This function is useful
for cases in which attention should be paid to ensure a circuit
breaker will not trip when the product runs alongside other
appliances.
INFORMATION
•
Powerful and Econo operation CANNOT be used at the
same time. The last selected function takes priority.
•
Econo operation reduces power consumption of the outdoor
unit by limiting the rotation speed of the compressor. If power
consumption is already low, Econo operation will NOT further
reduce power consumption.
Outdoor unit quiet operation
Use Outdoor unit quiet operation when you want to decrease
the noise level of the outdoor unit.
Example
: At night.
INFORMATION
•
Powerful and Outdoor unit quiet operation CANNOT be used
at the same time. The last selected function takes priority.
•
This function is only available in Automatic, Cooling, and
Heating operation.
•
Outdoor unit quiet operation limits the rotation speed of the
compressor. If the rotation speed of compressor is already
low, Outdoor unit quiet operation will NOT further reduce the
compressor rotation speed.
To start/stop Econo and Outdoor unit quiet operation
1.
Press
one or more times.
Result:
The setting will change as follows.
Display
Operation
Econo
Outdoor unit quiet
+
Econo and Outdoor unit quiet
—
Both deactivated
2.
To stop operation, press
until both symbols
disappear from the LCD.
Note:
Econo operation can be only set when the unit is running.
Pressing
cancels the setting and
disappears from the LCD.
Note:
remains on the LCD, even if you turn off the unit
using the remote controller or indoor unit ON/OFF switch.
•
If using a multi system, the OUTDOOR UNIT QUIET
operation will work only when this function is set on all
operated indoor units. However, if using priority room setting,
refer to “
Note for Multi System
” on page 16.
10
01_EN_3P620957-1.indd 10
26-Jun-20 10:17:32 AM